Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

A Method of Measuring the Axial Secular Motion Temperature of Trapping Large Size Ion Clouds

Yu-Na Yang, Hao Liu, Yue-Hong He, Haixia Li, Yi-He Chen, Lei She, Liang Chen, Jiaomei Li

Published Mar 1, 2013• 0 citations
Publisher

Abstract

A large cloud of 40 Ca + is successfully trapped and manipulated in a linear ion trap. The axial length of the ion cloud is measured under a series of end-cap voltages. We propose a method of measuring the axial secular motion temperature of the ion cloud by analyzing its image on an electron-multiplying CCD. The method is based on the Boltzmann equation that the axial density distribution of ions at secular motion temperature T satisfies. The axial secular motion temperature of the ion cloud is also obtained by measuring the Doppler broadened line width. For the same trapping parameters, the axial secular motion temperature by analyzing the image of ion cloud is 840 K and by fitting the experimental resonance line profile is 700 K.

DOI
10.1088/0256-307x/30/3/030501

Related papers

Measurement of the secular motion frequency and the space charge density in the linear ion trap

Fei Zhou, Yiyang Xie, You-Yang Xu +2 more

This paper reports that a cloud of laser-cooled 40 Ca + is successfully trapped and manipulated in the home-built linear ion trap constructed for quantum information processing (QIP). The frequency of the secular motion and the space charge density of the ion cloud are measured, which help knowing the characteristic of the trapping potential and are the prerequisite of QIP with the trapped ions.

Chinese Physics B•Nov 1, 2010•3 citations

Doppler sideband spectra for ions in a linear trap

John D. Prestage, Robert L. Tjoelker, G.J. Dick +1 more

The authors describe a spectroscopic measurement of the temperature and linear density of Hg/sup +/ ions held in a linear ion trap (LIT). The inferred temperature and number result from analysis of sidebands on the 40.5 GHz resonance line. The temperature of the ion cloud is determined by the Doppler-broadened line when microwave radiation is propagated along the axis of the LIT. When propagation is perpendicular to the trap axis, the microwave sidebands are displaced from the trap secular frequency by an amount dependent on the ion cloud size and temperature. A Monte Carlo simulation of the ion trajectories inside the cloud is used to model the position of these sidebands for a given cloud temperature, and a comparison with measured sideband position is used to determine ion number. In clock operation with 7 /spl times/ 10/sup -14/ /spl tau//sup -1/2/ stability, the method described here was used to measure a -8.8 /spl times/ 10/sup -13/ frequency offset due to second order Doppler shift at 650 K and a linear ion density of 2.5 /spl times/ 10/sup 6//75 mm.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 30, 2002•13 citations

Measurement of Secular Motion Frequency in Miniature Paul Trap to Ascertain the Stability Parameters

Bin Guo, Guan Hua, Liu Qu +3 more

40 Ca + ions are trapped and laser cooled in a miniature Paul trap. The secular motion was observed by the radio-frequency resonance of the ion cloud and Zeeman profile sidebands of a single ion experimentally. The trap stability parameters a and q are determined with an uncertainty under 1 % by the secular motion frequency measurement. The trap efficiency is 0.75. A practicable suggestion is given for the benefits of a new trap design.

Chinese Physics Letters•Jan 1, 2010•4 citations

Kinetic energy measurements of ions stored in a RF trap by use of phase-stopped ejection and retarding potential methods

R.-J. Champeau, A. Crubellier, J O Gaardsted +2 more

The kinetic energy distribution of a cloud of ions stored in a RF trap has been investigated by use of two methods based on phase-stopped ejection. The oscillation of the RF voltage is stopped at a phase corresponding to zero field Value inside the trap. After their subsequent ejection from the trap, the ions are detected by an electron multiplier. The instantaneous ion cloud temperature value corresponding to the phase-stopping time can be deduced from the recorded profile of the ion signal. An alternative method consists in submitting the ejected ions to a repulsive field, applied before the detector, which allows us to discriminate the velocity classes. In both cases, the experiments are interpreted thanks to a simple theoretical description of a cloud of ions at thermal equilibrium in a RF trap and to a precise calculation of the ejection process. Both methods are compared, for the various trap working points. In all cases, the ion cloud average temperature is of the order of a tenth of the potential well depth.

Journal of Physics B Atomic Molecular and Optical Physics•Mar 14, 1994•4 citations

Experimental techniques for cold chemistry and molecular spectroscopy in an ion trap

Kevin Sheridan

A range of experimental techniques for application in reaction studies between ionic and neutral atoms/molecules and high resolution spectroscopy experiments with sympathetically cooled molecular ions are presented. A novel ion trap loading scheme using the photo-ionisation of atoms generated by the pulsed laser ablation of a solid calcium target has been characterised. We have identified the range of ablation laser fluences that must be used in order to produce a flux of neutral calcium atoms, which is a prerequisite for isotope selective ion trap loading. Calcium ions are trapped and laser cooled in a linear radio-frequency ion trap. We have developed a spectroscopy scheme that allows the entire fluorescence spectrum of trapped ions to be rapidly collected with high precision while maintaining a low ion temperature and good ion localisation throughout interrogation. The scheme has been demonstrated by measuring the saturation intensity of the calcium ion 4S1/2?4P1/2 transition. We have developed a novel scheme to measure the secular motion of trapped ions and demonstrated the application of the technique to ion-neutral collision reaction experiments. Employing pulsed excitation and Doppler velocimetry, we have measured the centre-of-mass mode frequency of single ions as well as large ion crystals with a frequency precision better than 2x10-3 within an interrogation time on the order of seconds. This method has been used to measure the mass of ions and observe charge exchange collisions between trapped calcium isotopes. In particular, we have measured the 44Ca++40Ca!40Ca++44Ca reaction cross section and demonstrated the single-event resolution of the technique. Finally, we have developed a novel all-optical broadband scheme for exciting, amplifying and measuring the secular motion of ions in the trap. Oscillation induced by optical excitation has been coherently amplified to control and measure the ion's secular motion. Requiring only a single interrogation laser, the ion's oscillation amplitude can be precisely controlled. The application of this technique to non-destructive spectroscopy of trapped molecular ions is discussed.

•Oct 3, 2013•0 citations

Determination of the geometric parameters and of a linear Paul trap

H.X. Li, Yi Zhang, Shuxian He +1 more

An effective method for determining the geometric parameters of a linear Paul trap is provided and carried out in this paper. The method is based on exciting the secular motion of laser-cooled Ca+ ions in a linear Paul trap with varied trapping potentials. Taking advantage of the segmented structure of the linear Paul trap, both the axial and the radial geometric parameters are obtained by applying external excitation fields to the trapping electrodes directly. The axial geometric parameter of our linear Paul trap is determined to be 0.374(3), and, for the first time, the radial geometric parameter is determined to be 0.928(2).

Chinese Journal of Physics•May 1, 2019•14 citations
A large cloud of 40 Ca + is successfully trapped and manipulated in a linear ion trap. The axial length of the ion cloud is measured under a series of end-cap voltages. We propose a method of measuring the axial secular motion temperature of the ion cloud by analyzing its image on an electron-multiplying CCD. The method is based on the Boltzmann equation that the axial density distribution of ions at secular motion temperature T satisfies. The axial secular motion temperature of the ion cloud is also obtained by measuring the Doppler broadened line width. For the same trapping parameters, the axial secular motion temperature by analyzing the image of ion cloud is 840 K and by fitting the experimental resonance line profile is 700 K.
The authors describe a spectroscopic measurement of the temperature and linear density of Hg/sup +/ ions held in a linear ion trap (LIT). The inferred temperature and number result from analysis of sidebands on the 40.5 GHz resonance line. The temperature of the ion cloud is determined by the Doppler-broadened line when microwave radiation is propagated along the axis of the LIT. When propagation is perpendicular to the trap axis, the microwave sidebands are displaced from the trap secular frequency by an amount dependent on the ion cloud size and temperature. A Monte Carlo simulation of the ion trajectories inside the cloud is used to model the position of these sidebands for a given cloud temperature, and a comparison with measured sideband position is used to determine ion number. In clock operation with 7 /spl times/ 10/sup -14/ /spl tau//sup -1/2/ stability, the method described here was used to measure a -8.8 /spl times/ 10/sup -13/ frequency offset due to second order Doppler shift at 650 K and a linear ion density of 2.5 /spl times/ 10/sup 6//75 mm.>
The kinetic energy distribution of a cloud of ions stored in a RF trap has been investigated by use of two methods based on phase-stopped ejection. The oscillation of the RF voltage is stopped at a phase corresponding to zero field Value inside the trap. After their subsequent ejection from the trap, the ions are detected by an electron multiplier. The instantaneous ion cloud temperature value corresponding to the phase-stopping time can be deduced from the recorded profile of the ion signal. An alternative method consists in submitting the ejected ions to a repulsive field, applied before the detector, which allows us to discriminate the velocity classes. In both cases, the experiments are interpreted thanks to a simple theoretical description of a cloud of ions at thermal equilibrium in a RF trap and to a precise calculation of the ejection process. Both methods are compared, for the various trap working points. In all cases, the ion cloud average temperature is of the order of a tenth of the potential well depth.
A range of experimental techniques for application in reaction studies between ionic and neutral atoms/molecules and high resolution spectroscopy experiments with sympathetically cooled molecular ions are presented. A novel ion trap loading scheme using the photo-ionisation of atoms generated by the pulsed laser ablation of a solid calcium target has been characterised. We have identified the range of ablation laser fluences that must be used in order to produce a flux of neutral calcium atoms, which is a prerequisite for isotope selective ion trap loading. Calcium ions are trapped and laser cooled in a linear radio-frequency ion trap. We have developed a spectroscopy scheme that allows the entire fluorescence spectrum of trapped ions to be rapidly collected with high precision while maintaining a low ion temperature and good ion localisation throughout interrogation. The scheme has been demonstrated by measuring the saturation intensity of the calcium ion 4S1/2?4P1/2 transition. We have developed a novel scheme to measure the secular motion of trapped ions and demonstrated the application of the technique to ion-neutral collision reaction experiments. Employing pulsed excitation and Doppler velocimetry, we have measured the centre-of-mass mode frequency of single ions as well as large ion crystals with a frequency precision better than 2x10-3 within an interrogation time on the order of seconds. This method has been used to measure the mass of ions and observe charge exchange collisions between trapped calcium isotopes. In particular, we have measured the 44Ca++40Ca!40Ca++44Ca reaction cross section and demonstrated the single-event resolution of the technique. Finally, we have developed a novel all-optical broadband scheme for exciting, amplifying and measuring the secular motion of ions in the trap. Oscillation induced by optical excitation has been coherently amplified to control and measure the ion's secular motion. Requiring only a single interrogation laser, the ion's oscillation amplitude can be precisely controlled. The application of this technique to non-destructive spectroscopy of trapped molecular ions is discussed.
An effective method for determining the geometric parameters of a linear Paul trap is provided and carried out in this paper. The method is based on exciting the secular motion of laser-cooled Ca+ ions in a linear Paul trap with varied trapping potentials. Taking advantage of the segmented structure of the linear Paul trap, both the axial and the radial geometric parameters are obtained by applying external excitation fields to the trapping electrodes directly. The axial geometric parameter of our linear Paul trap is determined to be 0.374(3), and, for the first time, the radial geometric parameter is determined to be 0.928(2).