Performance at585GHzofaSlot-Ring AntennaCoupled NiobiumHEB MixerElement forImaging Applications

L. Liu, Haidi Xu, Q. F. Xiao, A. W. Lichtenberger, M. Weikle, Charles L. BrownDepartment

Published Jan 1, 2005• 0 citations
OpenAlex

Abstract

GHz diffusion-cooled Nb HEB (d-HEB) mixers utilizing slot-ring antennas havebeendesigned and fabricated onsilicon wafers. Tooptimize powercoupling fromtheantennas tothemixing elements, twoimpedance matching schemes areproposed. Performance at585GHz ofthemixers including I-Vcurves, conversion gainand noise temperature arepresented.

Related papers

Performance at 585 GHz of a Slot-Ring Antenna Coupled Niobium HEB Mixer Element for Imaging Applications

Lian Liu, H. Xu, Q. Xiao +2 more

585 GHz diffusion-cooled Nb HEB (d-HEB) mixers utilizing slot-ring antennas have been designed and fabricated on silicon wafers. To optimize power coupling from the antennas to the mixing elements, two impedance matching schemes are proposed. Performance at 585 GHz of the mixers including I-V curves, conversion gain and noise temperature are presented.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Jan 18, 2006•0 citations

Detailed Characterization of Quasi-Optically Coupled Nb Hot Electron Bolometer Mixers in the 0.6-3 THz Range

W. F. M. Ganzevles, Pavel A. Yagoubov, W. J. Vreeling +3 more

Two type of Nb diffusion-cooled HEB mixers have been studied. One uses a twin-slot antenna designed for 700 GHz, and has a bridge length of 200 nm. This device is fabricated using an in situ-process for the interface between the bridge and the cooling pads. An uncorrected receiver noise temperature of 1200 K at 640 GHz and an IF bandwidth of 5 GHz have been measured. The second device uses a log-periodic antenna designed for a wide RF bandwidth. However, there is a misalignment of the Nb bridge with respect to the Au cooling pads. Receiver noise temperatures at 0.64, 1.9, and 2.5 THz have been measured. We are able to link the geometry feature to the measured properties. 1.

•Mar 1, 2002•0 citations

Design, Fabrication and Characterization of a Submillimeter-Wave Niobium HEB Mixer Imaging Array Based on the “Reverse-Microscope” Concept

Lei Liu, Qun Xiao, Haiyong Xu +3 more

Prototype one-dimensional (1-D) superconducting hot-electron bolometer (HEB) imaging mixer arrays with four pixels, designed for operation at 585 GHz, and based on slot-ring antennas arranged in the "reverse-microscope" configuration have been fabricated and implemented. Electromagnetic simulations with Agilent's Momentum software package have been performed to study the self- and mutual-impedances of the slot-ring antenna (SRA) array corresponding to various element spacings. Moreover, the element SRA off-axis radiation patterns (with an extended silicon lens) have been calculated using ray-tracing techniques and the imaging angular resolution has been predicted. Fabrication of the arrays and HEB elements are discussed, and measurements for a single mixer element are presented, yielding a double sideband (DSB) receiver noise temperature of approximately 650 K at 585 GHz.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•9 citations

Noise and Bandwidth Measurements of Diffusion-Cooled Nb Hot-Electron Bolometer Mixers at Frequencies Above the Superconductive Energy Gap

Rolf A. Wyss, Boris S. Karasik, William R. McGrath +2 more

Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.

Softwaretechnik-Trends•Jan 1, 1999•20 citations

HEZ §uperconductive Nb t-Electron Mixer

Boris S. Karasik, B. Bumble

AbstracF-we report on the development of a quasioptical Nb hot-electron bolometer mixer for a 2.5 THz heterodyne receiver. The devices are fabricated from a 12 nm thick Nb film, and have a 0.30 ~mx0.15 pm in-plane size, thus exploiting diffusion as the electron cooling mechanism. The rf coupling was provided by a twin-slot planar antenna on an elliptical Si lens. A specially designed 2.5 THz system, using a laser as local oscillator (LO), with rf hotkold loads enclosed in vacuum to avoid atmospheric absorption, was used in the experiment. The experimentally measured double sideband (DSB) noise temperature of the receiver was as low as 53000 K, with an estimated mixer noise temperature of = 750 K. These results demonstrate the operation of the diffusion-cooled bolometer mixer above

•Jan 1, 1997•0 citations

Gain Bandwidth and Noise Temperature of NbN HEB Mixers with Simultaneous Phonon and Diffusion Cooling

Anna Maslennikova, Ivan V. Tretyakov, Рябчун Сергей Александрович +4 more

The space observatory Millimetron will be operating in the millimeter, sub-millimeter and infrared ranges using a 12-m cryogenic telescope in a single-dish mode, and as an interferometer with the space-earth and space-space baselines (the latter after the launch of the second identical space telescope). The observatory will allow performing astronomical observations with an unprecedented sensitivity (down to nJy level) in the single-dish mode, and observations with a high angular resolution in the interferometer mode. The total spectral range 20 μm – 2 cm is separated into 10 bands. HEB mixers with two cooling channels (diffusion and phonon) have been chosen to be the detectors of choice of the system covering the range from 1 THz to 6 THz as the best detectors in terahertz receivers. This type of HEB has already shown good work in the terahertz range. A gain bandwidth of 6 GHz at an LO frequency of 300 GHz and a noise temperature of 750 K at an LO frequency of 2.5 THz are the best values for HEB mixers with two cooling channels [1]. Theoretical estimations predict a bandwidth up to 12 GHz. Reaching such good result demands more systematic and thorough research. We present the results of the gain bandwidth and noise temperature measurements for superconducting hotelectron bolometer mixers with two cooling channels. These characteristics of the devices of lengths varying from 50 to 200 nm were measured for the purposes of Millimetron at frequencies of 600 GHz, 2.5 THz, and 3.8 THz. For gain bandwidth measurements we use two BWO’s operating at 600 GHz: one as the signal and the second as the LO. The noise temperature measurements were performed using a gas discharge laser as the LO and blackbodies at 77 K and 295 K as input signals. The devices studied consist of 3.5-nm-thick NbN bridges connected to thick (10 nm) high conductivity Au leads fabricated in situ. This method of fabricating devices has already proved promising by opening the diffusion cooling channel. [2] Fig. 1 shows a SEM photograph of a log-spiral antenna with an HEB at its apex. Fig. 1. Left: a SEM photograph of a log-spiral antenna with an HEB at its apex; right: a close-up of the HEB at the antenna apex. [1] S. A. Ryabchun, I. V. Tretyakov, M. I. Finkel, S. N. Maslennikov, N. S. Kaurova, V. A. Seleznev, B. M. Voronov, and G. N. Gol’tsman, NbN phonon-cooled hot-electron bolometer mixer with additional diffusion cooling, Proc. of the 20 Int. Symp. Space. Technol., Charlottesville, Virginia, USA, April 20 – 22, 2009.

•Mar 1, 2010•0 citations
Two type of Nb diffusion-cooled HEB mixers have been studied. One uses a twin-slot antenna designed for 700 GHz, and has a bridge length of 200 nm. This device is fabricated using an in situ-process for the interface between the bridge and the cooling pads. An uncorrected receiver noise temperature of 1200 K at 640 GHz and an IF bandwidth of 5 GHz have been measured. The second device uses a log-periodic antenna designed for a wide RF bandwidth. However, there is a misalignment of the Nb bridge with respect to the Au cooling pads. Receiver noise temperatures at 0.64, 1.9, and 2.5 THz have been measured. We are able to link the geometry feature to the measured properties. 1.
Prototype one-dimensional (1-D) superconducting hot-electron bolometer (HEB) imaging mixer arrays with four pixels, designed for operation at 585 GHz, and based on slot-ring antennas arranged in the "reverse-microscope" configuration have been fabricated and implemented. Electromagnetic simulations with Agilent's Momentum software package have been performed to study the self- and mutual-impedances of the slot-ring antenna (SRA) array corresponding to various element spacings. Moreover, the element SRA off-axis radiation patterns (with an extended silicon lens) have been calculated using ray-tracing techniques and the imaging angular resolution has been predicted. Fabrication of the arrays and HEB elements are discussed, and measurements for a single mixer element are presented, yielding a double sideband (DSB) receiver noise temperature of approximately 650 K at 585 GHz.
Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.
AbstracF-we report on the development of a quasioptical Nb hot-electron bolometer mixer for a 2.5 THz heterodyne receiver. The devices are fabricated from a 12 nm thick Nb film, and have a 0.30 ~mx0.15 pm in-plane size, thus exploiting diffusion as the electron cooling mechanism. The rf coupling was provided by a twin-slot planar antenna on an elliptical Si lens. A specially designed 2.5 THz system, using a laser as local oscillator (LO), with rf hotkold loads enclosed in vacuum to avoid atmospheric absorption, was used in the experiment. The experimentally measured double sideband (DSB) noise temperature of the receiver was as low as 53000 K, with an estimated mixer noise temperature of = 750 K. These results demonstrate the operation of the diffusion-cooled bolometer mixer above
The space observatory Millimetron will be operating in the millimeter, sub-millimeter and infrared ranges using a 12-m cryogenic telescope in a single-dish mode, and as an interferometer with the space-earth and space-space baselines (the latter after the launch of the second identical space telescope). The observatory will allow performing astronomical observations with an unprecedented sensitivity (down to nJy level) in the single-dish mode, and observations with a high angular resolution in the interferometer mode. The total spectral range 20 μm – 2 cm is separated into 10 bands. HEB mixers with two cooling channels (diffusion and phonon) have been chosen to be the detectors of choice of the system covering the range from 1 THz to 6 THz as the best detectors in terahertz receivers. This type of HEB has already shown good work in the terahertz range. A gain bandwidth of 6 GHz at an LO frequency of 300 GHz and a noise temperature of 750 K at an LO frequency of 2.5 THz are the best values for HEB mixers with two cooling channels [1]. Theoretical estimations predict a bandwidth up to 12 GHz. Reaching such good result demands more systematic and thorough research. We present the results of the gain bandwidth and noise temperature measurements for superconducting hotelectron bolometer mixers with two cooling channels. These characteristics of the devices of lengths varying from 50 to 200 nm were measured for the purposes of Millimetron at frequencies of 600 GHz, 2.5 THz, and 3.8 THz. For gain bandwidth measurements we use two BWO’s operating at 600 GHz: one as the signal and the second as the LO. The noise temperature measurements were performed using a gas discharge laser as the LO and blackbodies at 77 K and 295 K as input signals. The devices studied consist of 3.5-nm-thick NbN bridges connected to thick (10 nm) high conductivity Au leads fabricated in situ. This method of fabricating devices has already proved promising by opening the diffusion cooling channel. [2] Fig. 1 shows a SEM photograph of a log-spiral antenna with an HEB at its apex. Fig. 1. Left: a SEM photograph of a log-spiral antenna with an HEB at its apex; right: a close-up of the HEB at the antenna apex. [1] S. A. Ryabchun, I. V. Tretyakov, M. I. Finkel, S. N. Maslennikov, N. S. Kaurova, V. A. Seleznev, B. M. Voronov, and G. N. Gol’tsman, NbN phonon-cooled hot-electron bolometer mixer with additional diffusion cooling, Proc. of the 20 Int. Symp. Space. Technol., Charlottesville, Virginia, USA, April 20 – 22, 2009.