Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of the IEEE

Josephson junction millimeter microwave source and homodyne detector

B. T. Ulrich, E.O. Kluth

Published Jan 1, 1973• 18 citations
Publisher

Abstract

A millimeter and submillimeter microwave source is described in which a point-contact Josephson junction is used as both the emitter and as a homodyne detector of the microwave radiation. The microwave radiation is conveyed from the Josephson junction to the room-temperature environment outside the Dewar of liquid helium by an oversize waveguide. A room-temperature Fabry-Perot resonator refocuses the radiation on the oversize waveguide which returns the radiation to the emitting junction which also serves as a coherent detector with sensitivity 10-15W/√Hz. The detector is sufficiently sensitive that the emitted power of 10-12W can be detected with high signal-to-noise ratio. Power required by the junction is of the order 10-6W from the bias supply. For the experiments reported, the wavelength of the emission could be varied over discrete wavelengths between 1.1 and 2.6 mm by varying the voltage bias across the junction. These wavelengths corresponded to the resonant frequencies of a cavity tightly coupled to the Josephson junction, and the frequencies can be changed by modifying the geometry of the cavity.

DOI
10.1109/proc.1973.8969

Related papers

Tunable far infrared radiation from Josephson junctions

Richard K. Elsley, Albert J. Sievers

Although a number of investigators have generated microwave radiation by means of properly biased Josephson junctions, little work has been reported on similar applications to the submillimeter wave region where tunable coherent oscillators are not yet available. We have generated continuously tunable millimeter and submillimeter wave radiation with a point contact Josephson junction in a superconducting transmission line. This transmission line is centered in an oversized multimode brass cavity. With a broad band detector placed in the brass cavity near the transmission line radiation is detected for all bias voltages below 2 mV. The maximum power actually absorbed by the detector is about 2 × 10-10 W. In order to analyze the frequency content of the radiation we have used a lamellar interferometer together with Fourier transform spectroscopic techniques. The amount of power detected in the remote detector cryostat is two orders of magnitude smaller than that detected adjacent to the junction. Only at bias voltages where a particularly large amount of radiation is emitted are spectroscopic measurements possible. For these cases the frequency of the radiation is that predicted from the bias voltage and the Josephson relation. The linewidth is less than the resolution of the interferometer. To see if the radiation is continuously tunable a low temperature spectrometer has been constructed. The instrument consists of a germanium bolometer cooled to 0.3 K by a He3 charcoal adsorption pump, a four position sample rotator at 1.2 K and a Josephson junction transmission line source. By sweeping the bias voltage from zero to 2 mV absorption line spectra have been recorded in three different crystals, they are : 1. the antiferromagnetic resonance at 8.7 cm-1 in MnF2 ; 2. the impurity mode absorption at 14.3 cm-1 in CsI : Tl and 3. the impurity mode absorption at 18.0 cm-1 in KBr : Li. A low temperature double beam spectrometer is now under construction.

Revue de Physique Appliquée•Jan 1, 1974•4 citations

Millimeter wavelength coherent emission from high temperature superconducting bicrystal Josephson junction array

Yue Hong-Wei, Zheng Wang, Fan Bin +6 more

The experimental results of mm-wave coherent emission from a high temperature superconducting bicrystal Josephson junction array embedded in a Fabry-Perot resonator are reported in this paper.The mm-wave coherent emission from the series junction array results from the interaction of the junctions with the substrate serving as the dielectric resonator as well as the Fabry-Perot resonator.The central frequency of emission of a Josephson junction array containing 166 bicrystal junctions was 75.84 GHz,and the detected emission power was about 10 pW at 77 K.

Acta Physica Sinica•Jan 1, 2010•1 citation

ミリ波・サブミリ波検出器

Kazuo Fujisawa

In this report, Josephson junction detectors for millimeter and submillimeter waves are surveyed. Emphasis is placed on heterodyne detectors (mixers). Others are briefly referred to, such as video detectors, bolometers, quasiparticle mixers and parametric amplifiers. Also, three kinds of Josephson junctions for detector use are mentioned and brief comments are given on them. These are tunnel junctions, thin film microbridges and point contacts.Thermally cyclable oxide barrier tunnel junctions have been obtained and used as low noise quasiparticle mixers at 115GHz. They have lower noise temperatures compared to Josephson effect mixers, but the receiver noise temperatures are not lowered owing to their lower conversion efficiencies. Thin film microbridges suffer from low junction resistances and also from heating effects caused by d.c. bias supply and r.f. incident power. There seems to exist many problems to be overcome in order to make good submillimeter wave detectors by tunnel junctions or microbridges.Point contacts are now widely used as sensitive detectors for millimeter and submillimeter waves. Although there exist difficulties for making rugged and thermally cyclable point contacts, the techniques for making them have made considerable progress, and a new construction of detector mount has appeared, which brought a low noise mixer at 115GHz thermally cyclable.It is shown that the sensitivity of video detectors decreases as proportional to the inverse square of frequency. So, for submillimeter waves, video detectors are inferior to superconducting bolometers.Recent progress in heterodyne detectors (fundamental and harmonic mixers) are touched on. They are superior to Shottky diode mixers in that they have much smaller NEP's and much higher conversion efficiencies (especially in harmonic mixers), and also in that they operate with much smaller LO power. Experimental curves of IF output power v.s. bias voltage are given for harmonic mixers with harmonic number N=7 and N=10. It is noted that harmonic mixers with even harmonic number are preferable, because they can operate at zero bias voltage. Among them, low even numbers 2 or 4 are recommended in regards to good conversion efficiency.By using Josephson junctions, a peculiar parametric operation is possible, namely doubly degenerate mode. This mode operates under zero d.c. bias by choosing pump frequency as 2ωp=ωs+ωi, ωp-ωs-ωi. Zero bias operation allows the adoption of microbridge arrays. A parametric amplifier with 160 microbridge arrays was built at 33GHz, and showed amplifier gain of 15dB and noise temperature of 20K.

TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)•Jan 1, 1980•0 citations

Millimeter-wavelength radiation from arrays of discrete high-temperature superconductor Josephson junctions

Fangfang Song, M. Levitchev, Vadim A. Markelov +3 more

Josephson junction arrays could be competitive candidates for radiation sources in the frequency range from 0.5 to 1.5 THz. This is the range where compact solid-state continuous wave sources are most lacking. We investigated the millimeter-wave radiation from arrays of high-temperature superconductor bicrystal Josephson junctions embedded in a quasi-optical resonator. The novel approach of utilizing the intrinsic resonance modes of the substrate to improve the impedance coupling between the series array of discrete Josephson junctions and the quasi-optical resonator was investigated by experiments and electromagnetic field simulations. Radiation from the arrays containing up to 536 junctions was detected at about 80 GHz and liquid nitrogen temperature using a low-noise receiver. The detected maximum radiation power of the arrays was about 50 pW and the peak voltage agreed exactly with the Josephson current–voltage relation.

Superconductor Science and Technology•Feb 22, 2010•6 citations

Untuned Josephson detectors of microwave and millimeter-wave radiation

C. K. So, William O. Hamilton

The intrinsic response of Josephson junctions to microwave and far-infrared radiation is studied. Junctions are formed by pressing a Nb or Nb-Ti pointed wire onto a Nb thin film which in turn is pressed against the open end of a waveguide. Electromagnetic radiation is applied through the back of the film so that only the wave magnetic field is coupled to the junction. The change of the dc Josephson current is monitored at different levels of microwave power over a frequency range from 22 to 105 GHz. The dependence of the responsivity of these currents on film thickness over a range from 50 to 500 Å is studied. The observed responsivity agrees very well with that predicted by theory. Higher responsivity is observed for thinner films and lower microwave frequencies. The observed responsivity of a 50-Å film junction at 22 GHz is (6±3) ×10−2 V/W. To facilitate comparison of our results with other experiments, a more conventional coupling configuration in which the wave electric field rather than the wave magnetic field is coupled to the junction is studied. The results are comparable with other experiments with the responsivity in the E field coupling case 106 times larger than in the B field coupling configuration. We demonstrate that for successful use of simple Josephson junction detectors in the microwave and millimeter region it seems crucial to impedance match the junctions to the radiation source, probably by making them a part of a resonant structure.

Journal of Applied Physics•May 1, 1977•1 citation

THE JOSEPHSON JUNCTION AS A 100 GHz OSCILLATOR-MIXER,

Andrew Longacre, Sidney Shapiro

Abstract : The term 'Josephson effects' refers to a number of unusual properties of current flow through a barrier or weak link between two superconductors. Such a structure--called a Josephson junction--gives rise to frequency conversion effects that suggest its use as an oscillator-mixer in the millimeter and submillimeter region. Such a device would offer high sensitivity, broad bandwidth, tunability, and, in certain modes of operation, the possibility of conversion gain. These frequency conversion effects were observed in the range of 100 GHz to 600 GHz and beyond. The junctions were driven by a 75 GHz or 25 GHz klystron while coupled either to a coaxial cavity resonant at 20 GHz or to a resonance at about 500 GHz associated with the junction structure. Lines in the junction voltage-current characteristic were observed which demonstrated that, at certain values of junction bias, power at the rf--or its harmonics--was converted to power at the resonance frequency. An explanation of the experiment is given together with the necessary background, which provides the basis for a discussion of such operational considerations as upper frequency limit, sensitivity, temperature of operation, and saturation behavior at high signal levels. (Author)

•Apr 1, 1970•1 citation
A millimeter and submillimeter microwave source is described in which a point-contact Josephson junction is used as both the emitter and as a homodyne detector of the microwave radiation. The microwave radiation is conveyed from the Josephson junction to the room-temperature environment outside the Dewar of liquid helium by an oversize waveguide. A room-temperature Fabry-Perot resonator refocuses the radiation on the oversize waveguide which returns the radiation to the emitting junction which also serves as a coherent detector with sensitivity 10-15W/√Hz. The detector is sufficiently sensitive that the emitted power of 10-12W can be detected with high signal-to-noise ratio. Power required by the junction is of the order 10-6W from the bias supply. For the experiments reported, the wavelength of the emission could be varied over discrete wavelengths between 1.1 and 2.6 mm by varying the voltage bias across the junction. These wavelengths corresponded to the resonant frequencies of a cavity tightly coupled to the Josephson junction, and the frequencies can be changed by modifying the geometry of the cavity.
Although a number of investigators have generated microwave radiation by means of properly biased Josephson junctions, little work has been reported on similar applications to the submillimeter wave region where tunable coherent oscillators are not yet available. We have generated continuously tunable millimeter and submillimeter wave radiation with a point contact Josephson junction in a superconducting transmission line. This transmission line is centered in an oversized multimode brass cavity. With a broad band detector placed in the brass cavity near the transmission line radiation is detected for all bias voltages below 2 mV. The maximum power actually absorbed by the detector is about 2 × 10-10 W. In order to analyze the frequency content of the radiation we have used a lamellar interferometer together with Fourier transform spectroscopic techniques. The amount of power detected in the remote detector cryostat is two orders of magnitude smaller than that detected adjacent to the junction. Only at bias voltages where a particularly large amount of radiation is emitted are spectroscopic measurements possible. For these cases the frequency of the radiation is that predicted from the bias voltage and the Josephson relation. The linewidth is less than the resolution of the interferometer. To see if the radiation is continuously tunable a low temperature spectrometer has been constructed. The instrument consists of a germanium bolometer cooled to 0.3 K by a He3 charcoal adsorption pump, a four position sample rotator at 1.2 K and a Josephson junction transmission line source. By sweeping the bias voltage from zero to 2 mV absorption line spectra have been recorded in three different crystals, they are : 1. the antiferromagnetic resonance at 8.7 cm-1 in MnF2 ; 2. the impurity mode absorption at 14.3 cm-1 in CsI : Tl and 3. the impurity mode absorption at 18.0 cm-1 in KBr : Li. A low temperature double beam spectrometer is now under construction.
The experimental results of mm-wave coherent emission from a high temperature superconducting bicrystal Josephson junction array embedded in a Fabry-Perot resonator are reported in this paper.The mm-wave coherent emission from the series junction array results from the interaction of the junctions with the substrate serving as the dielectric resonator as well as the Fabry-Perot resonator.The central frequency of emission of a Josephson junction array containing 166 bicrystal junctions was 75.84 GHz,and the detected emission power was about 10 pW at 77 K.
In this report, Josephson junction detectors for millimeter and submillimeter waves are surveyed. Emphasis is placed on heterodyne detectors (mixers). Others are briefly referred to, such as video detectors, bolometers, quasiparticle mixers and parametric amplifiers. Also, three kinds of Josephson junctions for detector use are mentioned and brief comments are given on them. These are tunnel junctions, thin film microbridges and point contacts.Thermally cyclable oxide barrier tunnel junctions have been obtained and used as low noise quasiparticle mixers at 115GHz. They have lower noise temperatures compared to Josephson effect mixers, but the receiver noise temperatures are not lowered owing to their lower conversion efficiencies. Thin film microbridges suffer from low junction resistances and also from heating effects caused by d.c. bias supply and r.f. incident power. There seems to exist many problems to be overcome in order to make good submillimeter wave detectors by tunnel junctions or microbridges.Point contacts are now widely used as sensitive detectors for millimeter and submillimeter waves. Although there exist difficulties for making rugged and thermally cyclable point contacts, the techniques for making them have made considerable progress, and a new construction of detector mount has appeared, which brought a low noise mixer at 115GHz thermally cyclable.It is shown that the sensitivity of video detectors decreases as proportional to the inverse square of frequency. So, for submillimeter waves, video detectors are inferior to superconducting bolometers.Recent progress in heterodyne detectors (fundamental and harmonic mixers) are touched on. They are superior to Shottky diode mixers in that they have much smaller NEP's and much higher conversion efficiencies (especially in harmonic mixers), and also in that they operate with much smaller LO power. Experimental curves of IF output power v.s. bias voltage are given for harmonic mixers with harmonic number N=7 and N=10. It is noted that harmonic mixers with even harmonic number are preferable, because they can operate at zero bias voltage. Among them, low even numbers 2 or 4 are recommended in regards to good conversion efficiency.By using Josephson junctions, a peculiar parametric operation is possible, namely doubly degenerate mode. This mode operates under zero d.c. bias by choosing pump frequency as 2ωp=ωs+ωi, ωp-ωs-ωi. Zero bias operation allows the adoption of microbridge arrays. A parametric amplifier with 160 microbridge arrays was built at 33GHz, and showed amplifier gain of 15dB and noise temperature of 20K.
Josephson junction arrays could be competitive candidates for radiation sources in the frequency range from 0.5 to 1.5 THz. This is the range where compact solid-state continuous wave sources are most lacking. We investigated the millimeter-wave radiation from arrays of high-temperature superconductor bicrystal Josephson junctions embedded in a quasi-optical resonator. The novel approach of utilizing the intrinsic resonance modes of the substrate to improve the impedance coupling between the series array of discrete Josephson junctions and the quasi-optical resonator was investigated by experiments and electromagnetic field simulations. Radiation from the arrays containing up to 536 junctions was detected at about 80 GHz and liquid nitrogen temperature using a low-noise receiver. The detected maximum radiation power of the arrays was about 50 pW and the peak voltage agreed exactly with the Josephson current–voltage relation.
The intrinsic response of Josephson junctions to microwave and far-infrared radiation is studied. Junctions are formed by pressing a Nb or Nb-Ti pointed wire onto a Nb thin film which in turn is pressed against the open end of a waveguide. Electromagnetic radiation is applied through the back of the film so that only the wave magnetic field is coupled to the junction. The change of the dc Josephson current is monitored at different levels of microwave power over a frequency range from 22 to 105 GHz. The dependence of the responsivity of these currents on film thickness over a range from 50 to 500 Å is studied. The observed responsivity agrees very well with that predicted by theory. Higher responsivity is observed for thinner films and lower microwave frequencies. The observed responsivity of a 50-Å film junction at 22 GHz is (6±3) ×10−2 V/W. To facilitate comparison of our results with other experiments, a more conventional coupling configuration in which the wave electric field rather than the wave magnetic field is coupled to the junction is studied. The results are comparable with other experiments with the responsivity in the E field coupling case 106 times larger than in the B field coupling configuration. We demonstrate that for successful use of simple Josephson junction detectors in the microwave and millimeter region it seems crucial to impedance match the junctions to the radiation source, probably by making them a part of a resonant structure.
Abstract : The term 'Josephson effects' refers to a number of unusual properties of current flow through a barrier or weak link between two superconductors. Such a structure--called a Josephson junction--gives rise to frequency conversion effects that suggest its use as an oscillator-mixer in the millimeter and submillimeter region. Such a device would offer high sensitivity, broad bandwidth, tunability, and, in certain modes of operation, the possibility of conversion gain. These frequency conversion effects were observed in the range of 100 GHz to 600 GHz and beyond. The junctions were driven by a 75 GHz or 25 GHz klystron while coupled either to a coaxial cavity resonant at 20 GHz or to a resonance at about 500 GHz associated with the junction structure. Lines in the junction voltage-current characteristic were observed which demonstrated that, at certain values of junction bias, power at the rf--or its harmonics--was converted to power at the resonance frequency. An explanation of the experiment is given together with the necessary background, which provides the basis for a discussion of such operational considerations as upper frequency limit, sensitivity, temperature of operation, and saturation behavior at high signal levels. (Author)