Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Potential for improving the rubidium frequency standard with a novel optical pumping scheme using diode lasers

Natarajan D. Bhaskar

Published Dec 30, 2002• 0 citations
Publisher

Abstract

It is experimentally demonstrated that, using diode lasers for optical pumping and RF /spl pi/-pulses for population transfer, nearly all of the ground state Rb atoms in a vapor cell can be concentrated into one of the two M/sub F/ = 0 sublevels. The fractional population difference /spl Delta/ between the two M/sub F/ = 0 levels can be made as high as 1. This should result in a very significant improvement (about a factor of 100) in the S/N over the conventional discharge-lamp-pumped rubidium frequency standards (RFSs). This would lead to a substantial improvement in the short-term stability of the RFS. This is a pulsed population transfer scheme. The microwave interrogation takes place in the absence of strong pumping light. This has the potential for eliminating the light shift and thereby improving the long-term frequency stability of a an RFS.>

DOI
10.1109/freq.1993.367382

Related papers

Potential for improving the Rubidium Frequency Standard with a novel optical pumping scheme using diode lasers

Natarajan D. Bhaskar

Frequency stability of a Rubidium Frequency Standard (RFS) is directly related to the signal-to-noise ratio (S/N) of the microwave-induced (6834 MHz) optical signal which is proportional to the fractional atomic population difference between the two M/sub F/=0 ground state sublevels of /sup 87/Rb. In the present RFSs this fractional population difference is small (>

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jan 1, 1995•16 citations

A compact, high-performance laser-pumped rubidium atomic frequency standard

C. Affolderbach, G. Mileti, Fabien Droz

The paper presents the realisation of a high-performance vapour-cell atomic frequency standard demonstrator based on laser optical pumping. The development of such devices aims to fully exploit the advantages of using a narrow-band diode laser pump light source instead of the discharge lamps commonly used in Rb gas-cell clocks. These advantages include improved control over the pump light spectrum, higher selectivity of the optical pumping, and increased signal contrast, and thus show the potential for the realisation of Rb atomic clocks with improved short-term frequency stability.

European Quantum Electronics Conference (EQEC)•Jan 18, 2006•1 citation

Analysis of the light shift effect in the /sup 87/Rb frequency standard

F. Levi, Carlo Novero, A. Godone

The /sup 87/Rb cell frequency standard, optically pumped by a laser diode, is of great interest in the development of high short-term stability oscillators. We report experiments performed on a rubidium cell prototype aiming at evaluate the transfer of the laser noise to the hyperfine clock transition via the light shift effect, which appears to be the main contribution to the observed short term frequency stability in this kind of standard. Pulsed optical pumping will also be examined in order to strongly reduce the light shift effect and to achieve the theoretical limit never approached up to now despite the strong detected microwave signals.

Conference on Precision Electromagnetic Measurements•Dec 24, 2002•0 citations

Rubidium frequency standard with two-frequency laser pumping scheme

Georgy A. Kazakov, Boris G. Matisov

In this paper we compare two different excitation schemes of rubidium gas-cell frequency standard. We provide the stability estimations for one-frequency and two-frequency pumping schemes. Our calculations show the significant improvement of stability in the case of two-frequency scheme. It concerned with the absence of 'pockets' ('trap' states) and therefore with more efficient population collection on one of the working sublevels for two-pumping scheme.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 3, 2006•0 citations

A laser optically-pumped Rubidium vapour-cell frequency standard using a DFB laser diode

C. Affolderbach, G. Mileti, Fabien Droz

A laser optically-pumped vapour-cell atomic frequency standard ("Rb clock") using a DFB laser diode as pump light source is presented. The Rb clock is based on probing the ground-state hyperfine "clock" transition at 6.8 GHz of atomic87Rb, by optical-microwave double-resonance technique. The frequency stability of the clock is measured.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations

High performance vapour-cell frequency standards

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +4 more

We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between

Journal of Physics Conference Series•Jun 1, 2016•22 citations
It is experimentally demonstrated that, using diode lasers for optical pumping and RF /spl pi/-pulses for population transfer, nearly all of the ground state Rb atoms in a vapor cell can be concentrated into one of the two M/sub F/ = 0 sublevels. The fractional population difference /spl Delta/ between the two M/sub F/ = 0 levels can be made as high as 1. This should result in a very significant improvement (about a factor of 100) in the S/N over the conventional discharge-lamp-pumped rubidium frequency standards (RFSs). This would lead to a substantial improvement in the short-term stability of the RFS. This is a pulsed population transfer scheme. The microwave interrogation takes place in the absence of strong pumping light. This has the potential for eliminating the light shift and thereby improving the long-term frequency stability of a an RFS.>
The paper presents the realisation of a high-performance vapour-cell atomic frequency standard demonstrator based on laser optical pumping. The development of such devices aims to fully exploit the advantages of using a narrow-band diode laser pump light source instead of the discharge lamps commonly used in Rb gas-cell clocks. These advantages include improved control over the pump light spectrum, higher selectivity of the optical pumping, and increased signal contrast, and thus show the potential for the realisation of Rb atomic clocks with improved short-term frequency stability.
The /sup 87/Rb cell frequency standard, optically pumped by a laser diode, is of great interest in the development of high short-term stability oscillators. We report experiments performed on a rubidium cell prototype aiming at evaluate the transfer of the laser noise to the hyperfine clock transition via the light shift effect, which appears to be the main contribution to the observed short term frequency stability in this kind of standard. Pulsed optical pumping will also be examined in order to strongly reduce the light shift effect and to achieve the theoretical limit never approached up to now despite the strong detected microwave signals.
We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between