Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Precision Measurements Using a 300 mV Josephson Arbitrary Waveform Synthesizer

Samuel P. Benz, Paul D. Dresselhaus, Charles J. Burroughs, Norman F. Bergren

Published Jun 1, 2007• 52 citations
Publisher

Abstract

We have developed a Josephson digital-to-analog converter, otherwise know as a Josephson arbitrary waveform synthesizer, with 300 mV peak output voltage. This is the first system of its kind with demonstrated quantum accuracy. We show precision synthesized waveforms from dc to 100 kHz with measured distortion and harmonic content below 115 dBc (dB below the carrier or fundamental). The heart of the system is a superconducting microwave integrated circuit with two Josephson junction arrays biased in parallel for the microwave drive and connected in series to double the voltage for the audio frequency output waveforms. New superconducting integrated circuits with twice as many stacked junctions and improved microwave circuits have allowed us to more than double the output voltage of our recent system. We also demonstrate that quantum-based synthesized arbitrary waveforms (not just sine waves) can be used for precision measurements of a high-performance commercial analog-to-digital converter.

DOI
10.1109/tasc.2007.898138

Related papers

One-Volt Josephson Arbitrary Waveform Synthesizer

Samuel P. Benz, Steven B. Waltman, Anna E. Fox +6 more

A quantum-accurate waveform with an rms output amplitude of 1 V has been synthesized for the first time. This fourfold increase in voltage over previous systems was achieved through developments and improvements in bias electronics, pulse-bias techniques, Josephson junction array circuit fabrication, and packaging. A recently described ac-coupled bipolar pulse-bias technique was used to bias a superconducting integrated circuit with 25 600 junctions, which are equally divided into four series-connected arrays, into the second quantum state. We describe these advancements and present the measured 1 V spectra for 2 Hz and 10 Hz sine waves that remained quantized over a 0.4 mA current range. We also demonstrate a 2 kHz sine wave produced with another bias technique that requires no compensation current and remains quantized at an rms voltage of 128 mV over a 1 mA current range. Increasing the clock frequency to 19 GHz also allowed us to achieve a maximum rms output voltage for a single array of 330 mV.

IEEE Transactions on Applied Superconductivity•Sep 17, 2014•59 citations

RF Waveform Synthesizers With Quantum-Based Voltage Accuracy for Communications Metrology

P. F. Hopkins, Justus A. Brevik, Manuel A. Castellanos-Beltran +6 more

We review our development of Josephson-junction-based programmable reference sources to synthesize spectrally pure waveforms with quantum-based voltage accuracy for characterizing and improving future communication devices and systems. The goal is to provide sources that together span the entire radio frequency band, equivalent to seven orders of magnitude in frequency (20 kHz to 300 GHz). To synthesize waveforms in the microwave frequency band, we are extending the existing Josephson arbitrary waveform synthesizer (JAWS) technology used for ac voltage metrology at audio frequencies (<;20 kHz). Using new microwave circuits and experimental techniques, we demonstrate JAWS-based synthesis of single-tone waveforms at 1 GHz, with -49 dBm output power and 79 dBc spur-free dynamic range (SFDR). To synthesize waveforms in the millimeter-wave frequency band, we are exploiting single flux quantum (SFQ) superconducting digital technology to design circuits that amplify SFQ pulses using a network of pulse splitters. With our initial SFQ-based circuit, we demonstrate synthesis of a 4-GHz sine wave with -74 dBm output power and 70 dBc SFDR.

IEEE Transactions on Applied Superconductivity•Mar 8, 2019•23 citations

Measurement and analysis of high-frequency voltage errors in the Josephson arbitrary waveform synthesizer

Marco Kraus, D. Drung, Ralf Behr +4 more

Abstract This paper reports on the comparison of two Josephson arbitrary waveform synthesizers for frequencies up to 500 kHz. Both independent pulse-driven Josephson arrays produce a 10 mV RMS sinusoidal voltage. They are alternately connected to an analog-to-digital converter which serves as a transfer standard. The setup is capable to of synthesizing quantum-based waveforms using two different pulse-bias techniques. We use the Zero-Compensation method and a two-pole high-pass filter structure in the pulse-bias configuration of one system (the reference) to minimize the amplitude error for signal frequencies up to 500 kHz. Consequently, we are able to directly detect the high-frequency voltage errors in the other system (the device under test). The setup is used to measure differences between both systems, and the influence of parameter variation on the results with Type A uncertainties of 0.4 µV/V ( k = 1) in measurement times of 60 s. We find that the dominant sources of deviations above 10 kHz can be traced to the influence of the output cabling and the pulse bias on the synthesized voltage signal. Our analysis explains the origin and the reduction of these high-frequency voltage errors.

Measurement Science and Technology•Jul 9, 2020•13 citations

Performance Improvements for the NIST 1 V Josephson Arbitrary Waveform Synthesizer

Samuel P. Benz, Steven B. Waltman, Anna E. Fox +5 more

The performance of the NIST Josephson arbitrary waveform synthesizer has been improved such that it generates a root-mean-square (rms) output voltage of 1 V with an operating current range greater than 2 mA. Our previous 1 V JAWS circuit achieved this same maximum voltage over a current range of 0.4 mA by operating every Josephson junction in its second quantum state. The newest circuit synthesizes 1 V waveforms with the junctions operating in the first quantum state. The voltage per array is doubled because the number of junctions in each array was doubled through the use of improved microwave circuit designs that increased the bias uniformity to the junctions. We describe the circuit improvements and device operation, and we demonstrate the system capabilities by showing measured spectra of a 1 Hz sine wave and a dual-tone waveform. With only two arrays of the new circuit, we also synthesized a 128 mV sine wave without a compensation bias signal, which is one of the bias signals required for achieving 1 V. This is the same rms output voltage achieved with the previous circuit using four arrays.

IEEE Transactions on Applied Superconductivity•Nov 10, 2014•30 citations

A Microwave Quantum-Defined Millivolt Source

Akim A. Babenko, Nathan E. Flowers-Jacobs, Gregor Lasser +5 more

We demonstrate a tenfold increase in the amplitude of microwave-frequency waveforms generated by a quantum-defined superconducting voltage source, with an open-circuit signal of 17.56 mV rms at 1.005 GHz. The voltage source is an RF Josephson arbitrary waveform synthesizer (RF-JAWS) that utilizes a circuit that is cooled to 4 K and is composed of an array of 4500 Josephson junctions. These junctions are connected in series along the center conductor of a 50-$\Omega $superconducting coplanar waveguide transmission line. We introduce a new zero-forcing equalization technique for reducing distortion in drive current pulse patterns. This technique allows an increase in the amplitude of the quantum-based voltage waveforms while suppressing parasitic feedthrough signals to −75 dBc. Synthesizing a two-tone delta–sigma waveform, we monitor an audio-frequency 10-kHz tone of less than 100-$\mu \text{V}$rms amplitude while simultaneously measuring the 1.005-GHz tone of −28.12-dBm power in a 50-$\Omega $environment. The two-tone synthesis allows simultaneous verification of correct operation of the voltage source using time-efficient low-frequency measurement techniques as well as slower microwave measurements.

IEEE Transactions on Microwave Theory and Techniques•Nov 1, 2021•11 citations

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations
We have developed a Josephson digital-to-analog converter, otherwise know as a Josephson arbitrary waveform synthesizer, with 300 mV peak output voltage. This is the first system of its kind with demonstrated quantum accuracy. We show precision synthesized waveforms from dc to 100 kHz with measured distortion and harmonic content below 115 dBc (dB below the carrier or fundamental). The heart of the system is a superconducting microwave integrated circuit with two Josephson junction arrays biased in parallel for the microwave drive and connected in series to double the voltage for the audio frequency output waveforms. New superconducting integrated circuits with twice as many stacked junctions and improved microwave circuits have allowed us to more than double the output voltage of our recent system. We also demonstrate that quantum-based synthesized arbitrary waveforms (not just sine waves) can be used for precision measurements of a high-performance commercial analog-to-digital converter.
A quantum-accurate waveform with an rms output amplitude of 1 V has been synthesized for the first time. This fourfold increase in voltage over previous systems was achieved through developments and improvements in bias electronics, pulse-bias techniques, Josephson junction array circuit fabrication, and packaging. A recently described ac-coupled bipolar pulse-bias technique was used to bias a superconducting integrated circuit with 25 600 junctions, which are equally divided into four series-connected arrays, into the second quantum state. We describe these advancements and present the measured 1 V spectra for 2 Hz and 10 Hz sine waves that remained quantized over a 0.4 mA current range. We also demonstrate a 2 kHz sine wave produced with another bias technique that requires no compensation current and remains quantized at an rms voltage of 128 mV over a 1 mA current range. Increasing the clock frequency to 19 GHz also allowed us to achieve a maximum rms output voltage for a single array of 330 mV.
We review our development of Josephson-junction-based programmable reference sources to synthesize spectrally pure waveforms with quantum-based voltage accuracy for characterizing and improving future communication devices and systems. The goal is to provide sources that together span the entire radio frequency band, equivalent to seven orders of magnitude in frequency (20 kHz to 300 GHz). To synthesize waveforms in the microwave frequency band, we are extending the existing Josephson arbitrary waveform synthesizer (JAWS) technology used for ac voltage metrology at audio frequencies (<;20 kHz). Using new microwave circuits and experimental techniques, we demonstrate JAWS-based synthesis of single-tone waveforms at 1 GHz, with -49 dBm output power and 79 dBc spur-free dynamic range (SFDR). To synthesize waveforms in the millimeter-wave frequency band, we are exploiting single flux quantum (SFQ) superconducting digital technology to design circuits that amplify SFQ pulses using a network of pulse splitters. With our initial SFQ-based circuit, we demonstrate synthesis of a 4-GHz sine wave with -74 dBm output power and 70 dBc SFDR.
Abstract This paper reports on the comparison of two Josephson arbitrary waveform synthesizers for frequencies up to 500 kHz. Both independent pulse-driven Josephson arrays produce a 10 mV RMS sinusoidal voltage. They are alternately connected to an analog-to-digital converter which serves as a transfer standard. The setup is capable to of synthesizing quantum-based waveforms using two different pulse-bias techniques. We use the Zero-Compensation method and a two-pole high-pass filter structure in the pulse-bias configuration of one system (the reference) to minimize the amplitude error for signal frequencies up to 500 kHz. Consequently, we are able to directly detect the high-frequency voltage errors in the other system (the device under test). The setup is used to measure differences between both systems, and the influence of parameter variation on the results with Type A uncertainties of 0.4 µV/V ( k = 1) in measurement times of 60 s. We find that the dominant sources of deviations above 10 kHz can be traced to the influence of the output cabling and the pulse bias on the synthesized voltage signal. Our analysis explains the origin and the reduction of these high-frequency voltage errors.
The performance of the NIST Josephson arbitrary waveform synthesizer has been improved such that it generates a root-mean-square (rms) output voltage of 1 V with an operating current range greater than 2 mA. Our previous 1 V JAWS circuit achieved this same maximum voltage over a current range of 0.4 mA by operating every Josephson junction in its second quantum state. The newest circuit synthesizes 1 V waveforms with the junctions operating in the first quantum state. The voltage per array is doubled because the number of junctions in each array was doubled through the use of improved microwave circuit designs that increased the bias uniformity to the junctions. We describe the circuit improvements and device operation, and we demonstrate the system capabilities by showing measured spectra of a 1 Hz sine wave and a dual-tone waveform. With only two arrays of the new circuit, we also synthesized a 128 mV sine wave without a compensation bias signal, which is one of the bias signals required for achieving 1 V. This is the same rms output voltage achieved with the previous circuit using four arrays.
We demonstrate a tenfold increase in the amplitude of microwave-frequency waveforms generated by a quantum-defined superconducting voltage source, with an open-circuit signal of 17.56 mV rms at 1.005 GHz. The voltage source is an RF Josephson arbitrary waveform synthesizer (RF-JAWS) that utilizes a circuit that is cooled to 4 K and is composed of an array of 4500 Josephson junctions. These junctions are connected in series along the center conductor of a 50-$\Omega superconductingcoplanarwaveguidetransmissionline.Weintroduceanewzero−forcingequalizationtechniqueforreducingdistortionindrivecurrentpulsepatterns.Thistechniqueallowsanincreaseintheamplitudeofthequantum−basedvoltagewaveformswhilesuppressingparasiticfeedthroughsignalsto−75dBc.Synthesizingatwo−tonedelta–sigmawaveform,wemonitoranaudio−frequency10−kHztoneoflessthan100−superconducting coplanar waveguide transmission line. We introduce a new zero-forcing equalization technique for reducing distortion in drive current pulse patterns. This technique allows an increase in the amplitude of the quantum-based voltage waveforms while suppressing parasitic feedthrough signals to −75 dBc. Synthesizing a two-tone delta–sigma waveform, we monitor an audio-frequency 10-kHz tone of less than 100-superconductingcoplanarwaveguidetransmissionline.Weintroduceanewzero−forcingequalizationtechniqueforreducingdistortionindrivecurrentpulsepatterns.Thistechniqueallowsanincreaseintheamplitudeofthequantum−basedvoltagewaveformswhilesuppressingparasiticfeedthroughsignalsto−75dBc.Synthesizingatwo−tonedelta–sigmawaveform,wemonitoranaudio−frequency10−kHztoneoflessthan100−\mu \text{V}rmsamplitudewhilesimultaneouslymeasuringthe1.005−GHztoneof−28.12−dBmpowerina50−rms amplitude while simultaneously measuring the 1.005-GHz tone of −28.12-dBm power in a 50-rmsamplitudewhilesimultaneouslymeasuringthe1.005−GHztoneof−28.12−dBmpowerina50−\Omega $environment. The two-tone synthesis allows simultaneous verification of correct operation of the voltage source using time-efficient low-frequency measurement techniques as well as slower microwave measurements.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.