Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Journal of Chemical Physics

Effect of kinetic energy on the doping efficiency of cesium cations into superfluid helium droplets

Lei Chen, Jie Zhang, William M. Freund, Wei Kong

Published Jul 28, 2015• 19 citations
Publisher

Abstract

We present an experimental investigation of the effect of kinetic energy on the ion doping efficiency of superfluid helium droplets using cesium cations from a thermionic emission source. The kinetic energy of Cs(+) is controlled by the bias voltage of a collection grid collinearly arranged with the droplet beam. Efficient doping from ions with kinetic energies from 20 eV up to 480 V has been observed in different sized helium droplets. The relative ion doping efficiency is determined by both the kinetic energy of the ions and the average size of the droplet beam. At a fixed source temperature, the number of doped droplets increases with increasing grid voltage, while the relative ion doping efficiency decreases. This result implies that not all ions are captured upon encountering with a sufficiently large droplet, a deviation from the near unity doping efficiency for closed shell neutral molecules. We propose that this drop in ion doping efficiency with kinetic energy is related to the limited deceleration rate inside a helium droplet. When the source temperature changes from 14 K to 17 K, the relative ion doping efficiency decreases rapidly, perhaps due to the lack of viable sized droplets. The size distribution of the Cs(+)-doped droplet beam can be measured by deflection and by energy filtering. The observed doped droplet size is about 5 × 10(6) helium atoms when the source temperature is between 14 K and 17 K.

DOI
10.1063/1.4927471

Related papers

Ion capture in helium droplets: formation of cold ion-neutral clusters

Travis M. Falconer

Superfluid helium nanodroplets are used to cool ions and form ion-neutral clusters at a temperature of 0.37 K. A desolvation technique was developed that allowed for the study of captured ions by mass spectrometry. From the mass spectrometry results it was determined that helium droplets may successfully capture sodium cations with kinetic energy of ~200 eV. Clusters of the neutral molecules H2O, N2, and HCN with Na+ were observed. Based on binding strength considerations, it is argued that the desolvation process imparts little energy into the ion-neutral clusters, avoiding dissociation. This result leads to the conclusion that ion-neutral clusters are formed within the droplet prior to desolvation, indicating that the helium snowball that is assumed to form around Na+ does not prevent ion-neutral cluster formation. This conclusion is supported by ab initio calculations, the results of which indicate the presence of barrierless pathways for neutral molecule insertion into the helium snowball surrounding Na+. The process of ion capture by helium droplets was studied by comparison of measured ion-doped droplet size distributions to known pre-ion capture droplet size distributions. The measured ion-doped droplet size distributions were affected by nozzle temperature, ion kinetic energy, and ion mass. These factors primarily affect two parameters of the ion-doped droplet size distribution, the minimum droplet size threshold, Nthr, and the droplet size at maximum signal intensity, Nmax. The effects of the studied factors on the measured distributions cannot be explained in terms of currently accepted droplet cooling mechanisms. Analysis of the results suggests that droplet doping efficiency can be improved in several ways, including a higher flux of lower-energy ions. An apparatus for the production and focusing of alkali cations at high fluxes and low energies is described. This apparatus was able to produce higher ion currents at lower kinetic energies than previous ion sources.

•Jan 1, 2008•0 citations

Production of cold molecular ions in superfluid helium droplets

Arisa Iguchi, H Otani, Susumu Kuma +2 more

Synopsis The capability of helium droplets to isolate cryogenic molecular ions at a temperature of 0.4 K is exploited to observe ultracold molecular processes in the RIKEN Cryogenic Electrostatic (RICE) storage ring. The development of a pulsed droplet beam consisting of extremely large helium droplets up to 1011 atoms is a promising step to apply this unique and robust cooling method to a wide variety of molecular ions. Production of ions by photoionization of neutral species inside helium droplets will provide internally cold ions below the ring temperature of 4 K.

Journal of Physics Conference Series•Jan 1, 2020•0 citations

Rapidly pulsed helium droplet source

Dominik Pentlehner, Ricarda Riechers, Bernhard Dick +5 more

A pulsed valve connected to a closed-cycle cryostat was optimized for producing helium droplets. The pulsed droplet beam appeared with a bimodal size distribution. The leading part of the pulse consists of droplets suitable for doping with molecules. The average size of this part can be varied between 10(4) and 10(6) helium atoms, and the width of the distribution is smaller as compared to a continuous-flow droplet source. The system has been tested in a single pulse mode and at repetition rates of up to 500 Hz with almost constant intensity. The droplet density was found to be increased by more than an order of magnitude as compared to a continuous-flow droplet source.

Review of Scientific Instruments•Apr 1, 2009•87 citations

Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams

Yunteng He, Jie Zhang, Yang Li +2 more

We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He2(+) and He4(+), which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl4 doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He)(n)C(+), (He)(n)Cl(+), and (He)(n)CCl(+). Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

Review of Scientific Instruments•Aug 1, 2015•14 citations

Multiply Charged Helium Droplet Anions

Felix Laimer, Fábio Zappa, P. Scheier +1 more

Abstract The detection of multiply charged helium droplet anions is reported for the first time. By ionizing droplets of superfluid helium with low energy electrons (up to 25 eV), it was possible to produce droplets containing up to five negative charges, which remain intact on the timescale of the experiment. The appearance sizes for different charge states are determined and are found to be orders of magnitude larger than for the equivalent cationic droplets, starting at 4 million He atoms for dianions. Droplets with He*− as charge carriers show signs of being metastable, but this effect is quenched by the pickup of water molecules.

Chemistry - A European Journal•Jan 1, 2021•24 citations

Characterization of laser ablation as a means for doping helium nanodroplets

Patrick Claas, S.-O. Mende, Frank Stienkemeier

Helium nanodroplets are doped with metal atoms by means of laser evaporation. The material is evaporated directly in front of the helium nozzle by a pulsed laser. In comparison with conventional pickup from an oven we deduce that the droplets can be loaded with more than one atom per droplet on average. Conditions and efficiencies for loading are evaluated. Furthermore, metal ions can be attached to helium droplets by this method, allowing isolation of charged particles at temperatures below 1 K. In this way we can directly measure size distributions of helium nanodroplets which are compared to results using other techniques.

Review of Scientific Instruments•Aug 20, 2003•38 citations
We present an experimental investigation of the effect of kinetic energy on the ion doping efficiency of superfluid helium droplets using cesium cations from a thermionic emission source. The kinetic energy of Cs(+) is controlled by the bias voltage of a collection grid collinearly arranged with the droplet beam. Efficient doping from ions with kinetic energies from 20 eV up to 480 V has been observed in different sized helium droplets. The relative ion doping efficiency is determined by both the kinetic energy of the ions and the average size of the droplet beam. At a fixed source temperature, the number of doped droplets increases with increasing grid voltage, while the relative ion doping efficiency decreases. This result implies that not all ions are captured upon encountering with a sufficiently large droplet, a deviation from the near unity doping efficiency for closed shell neutral molecules. We propose that this drop in ion doping efficiency with kinetic energy is related to the limited deceleration rate inside a helium droplet. When the source temperature changes from 14 K to 17 K, the relative ion doping efficiency decreases rapidly, perhaps due to the lack of viable sized droplets. The size distribution of the Cs(+)-doped droplet beam can be measured by deflection and by energy filtering. The observed doped droplet size is about 5 × 10(6) helium atoms when the source temperature is between 14 K and 17 K.
Superfluid helium nanodroplets are used to cool ions and form ion-neutral clusters at a temperature of 0.37 K. A desolvation technique was developed that allowed for the study of captured ions by mass spectrometry. From the mass spectrometry results it was determined that helium droplets may successfully capture sodium cations with kinetic energy of ~200 eV. Clusters of the neutral molecules H2O, N2, and HCN with Na+ were observed. Based on binding strength considerations, it is argued that the desolvation process imparts little energy into the ion-neutral clusters, avoiding dissociation. This result leads to the conclusion that ion-neutral clusters are formed within the droplet prior to desolvation, indicating that the helium snowball that is assumed to form around Na+ does not prevent ion-neutral cluster formation. This conclusion is supported by ab initio calculations, the results of which indicate the presence of barrierless pathways for neutral molecule insertion into the helium snowball surrounding Na+. The process of ion capture by helium droplets was studied by comparison of measured ion-doped droplet size distributions to known pre-ion capture droplet size distributions. The measured ion-doped droplet size distributions were affected by nozzle temperature, ion kinetic energy, and ion mass. These factors primarily affect two parameters of the ion-doped droplet size distribution, the minimum droplet size threshold, Nthr, and the droplet size at maximum signal intensity, Nmax. The effects of the studied factors on the measured distributions cannot be explained in terms of currently accepted droplet cooling mechanisms. Analysis of the results suggests that droplet doping efficiency can be improved in several ways, including a higher flux of lower-energy ions. An apparatus for the production and focusing of alkali cations at high fluxes and low energies is described. This apparatus was able to produce higher ion currents at lower kinetic energies than previous ion sources.
Synopsis The capability of helium droplets to isolate cryogenic molecular ions at a temperature of 0.4 K is exploited to observe ultracold molecular processes in the RIKEN Cryogenic Electrostatic (RICE) storage ring. The development of a pulsed droplet beam consisting of extremely large helium droplets up to 1011 atoms is a promising step to apply this unique and robust cooling method to a wide variety of molecular ions. Production of ions by photoionization of neutral species inside helium droplets will provide internally cold ions below the ring temperature of 4 K.
A pulsed valve connected to a closed-cycle cryostat was optimized for producing helium droplets. The pulsed droplet beam appeared with a bimodal size distribution. The leading part of the pulse consists of droplets suitable for doping with molecules. The average size of this part can be varied between 10(4) and 10(6) helium atoms, and the width of the distribution is smaller as compared to a continuous-flow droplet source. The system has been tested in a single pulse mode and at repetition rates of up to 500 Hz with almost constant intensity. The droplet density was found to be increased by more than an order of magnitude as compared to a continuous-flow droplet source.
We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He2(+) and He4(+), which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl4 doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He)(n)C(+), (He)(n)Cl(+), and (He)(n)CCl(+). Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.
Abstract The detection of multiply charged helium droplet anions is reported for the first time. By ionizing droplets of superfluid helium with low energy electrons (up to 25 eV), it was possible to produce droplets containing up to five negative charges, which remain intact on the timescale of the experiment. The appearance sizes for different charge states are determined and are found to be orders of magnitude larger than for the equivalent cationic droplets, starting at 4 million He atoms for dianions. Droplets with He*− as charge carriers show signs of being metastable, but this effect is quenched by the pickup of water molecules.
Helium nanodroplets are doped with metal atoms by means of laser evaporation. The material is evaporated directly in front of the helium nozzle by a pulsed laser. In comparison with conventional pickup from an oven we deduce that the droplets can be loaded with more than one atom per droplet on average. Conditions and efficiencies for loading are evaluated. Furthermore, metal ions can be attached to helium droplets by this method, allowing isolation of charged particles at temperatures below 1 K. In this way we can directly measure size distributions of helium nanodroplets which are compared to results using other techniques.