Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Stability of relaxation processes in a quantum system as a main factor for achieving the high long-term frequency stability of a standard

E. N. Pestov

Published May 1, 2011• 0 citations
Publisher

Abstract

The processes of synchronous Zeeman's relaxation are investigated with simultaneous observing population difference, Mz(τ1) — and coherence, Mx(τ2), — components within a spin of system of87Rb atoms in cells with antirelaxation coating, when changing cell volume, operating temperature and pumping light intensity with D1— line. The existence of total relaxation ‘degeneracy’ is experimentally determined which is characterized through (t1≈ t2) — condition being necessary [1] for achieving a high long-term frequency stability of standards (in particular, quantum magnetometers). The procedure for investigating relaxation processes developed by the author could be useful for the realization of atomic frequency standards with a high long-term frequency stability.

DOI
10.1109/fcs.2011.5977809

Related papers

Microwave transitions and nonlinear magneto-optical rotation in anti-relaxation-coated cells

Dmitry Budker, Leo W. Hollberg, Derek F. Jackson Kimball +3 more

Using laser optical pumping, widths and frequency shifts are determined for microwave transitions between ground-state hyperfine components of $^{85}\mathrm{Rb}$ and $^{87}\mathrm{Rb}$ atoms contained in vapor cells with alkane antirelaxation coatings. The results are compared with data on Zeeman relaxation obtained in nonlinear magneto-optical rotation experiments, a comparison important for quantitative understanding of spin-relaxation mechanisms in coated cells. By comparing cells manufactured over a $40\text{\penalty1000-\hskip0pt}\text{year}$ period we demonstrate the long-term stability of coated cells, an important property for atomic clocks and magnetometers.

arXiv:physics/0408009•Physical Review A•Jan 27, 2005•128 citations

The influence of signals correlation on the long-term stability of a tandem of quantum magnetometers with laser pumping

M I Fedorov, Ермак Сергей Викторович, Mikhail V. Petrenko +1 more

The results of studies of the long-term frequency stability as a function of the correlation coefficient for a tandem of two quantum magnetometers with laser pumping of 87 Rb in wall-coated vapour cell are represented. Measurement scheme includes a low-frequency self-generating magnetometer and a quantum microwave discriminator working at magnetic dipole transitions of radio-optical end state resonance. The difference of synchronously detected signals is processed to determine the Allan variance as a function of averaging time and correlation coefficient of signals. These parameters are essentially dependent both on the pumping light intensity and polarization and the intensity of radio fields that are produced in the working cell.

Journal of Physics Conference Series•Aug 1, 2016•1 citation

Hyperfine frequency shift and Zeeman relaxation in alkali-metal-vapor cells with antirelaxation alkene coating

Eric Corsini, Todor S. Karaulanov, M. V. Balabas +1 more

An alkene-based antirelaxation coating for alkali-metal vapor cells exhibiting Zeeman relaxation times up to 77 s was recently identified by Balabas et al. The long relaxation times, two orders of magnitude longer than in paraffin- (alkane-) coated cells, motivate revisiting the question of what the mechanism is underlying wall-collision-induced relaxation and renew interest in applications of alkali-metal vapor cells to secondary frequency standards. We measure the width and frequency shift of the ground-state hyperfine $m{}_{F}=0\ensuremath{\rightarrow}m{}_{F}^{\ensuremath{'}}=0$ transition (clock resonance) in vapor cells with ${}^{85}$Rb and ${}^{87}$Rb atoms, with an alkene antirelaxation coating. We find that the frequency shift is slightly larger than for paraffin-coated cells and that the Zeeman linewidth scales linearly with the hyperfine frequency shift.

Physical Review A•Feb 14, 2013•43 citations

Characterization of high-temperature performance of cesium vapor cells with anti-relaxation coating

Wenhao Li, M. V. Balabas, Xiang Peng +4 more

Vapor cells with antirelaxation coating are widely used in modern atomic physics experiments due to the coating's ability to maintain the atoms' spin polarization during wall collisions. We characterize the performance of vapor cells with different coating materials by measuring longitudinal spin relaxation and vapor density at temperatures up to 95 °C. We infer that the spin-projection-noise-limited sensitivity for atomic magnetometers with such cells improves with temperature, which demonstrates the potential of antirelaxation coated cells in applications of future high-sensitivity magnetometers.

arXiv:1609.04867•Journal of Applied Physics•Feb 13, 2017•46 citations

Quantum magnetometers as a base for atomic clock

E. A. Sagitov, Ермак Сергей Викторович, Mikhail V. Petrenko +1 more

The possibility of the atomic clock based on two quantum magnetometer system development is demonstrated. One of the magnetometers is self-oscillation type, another is M z - type magnetometer based on end-state UHF resonance. The laser pumping of 87 Rb atoms placed into antirelaxation coated sell is provided. The magnetometers frequency difference fluctuations experimental results are represented and Allan deviation is determined. The role of the radio-optical resonance frequency light shift different components is denoted for the determination of the quantum magnetometers optimal operation mode. The effect of the light shift compensation is demonstrated.

Journal of Physics Conference Series•Nov 1, 2016•6 citations

Optical pumping and relaxation of atomic population in assorted conditions

Saptarshi Roy Chowdhury, Swarupananda Pradhan

Abstract Precise control and knowledge over atomic dynamics is central to the advancement of quantum technology. The different experimental conditions namely, atoms in a vacuum, antirelaxation coated and buffer gas filled atomic cells provide complementary platforms for such investigations. The extent of changes in optical pumping, velocity changing collision and hyperfine changing collision rates associated with these conditions are discussed. There is a phenomenal change in the optical density by a factor of >25 times in the presence of a control field in a buffer gas environment. We found confinement induced enhanced optical pumping as the mechanism behind the observed transparency in buffer gas cell. The diffusive velocity of atoms were measured to be ∼25 ± 12 m s−1 and ⩽8 ± 4 m s−1 for antirelaxation coated and buffer gas filled cells respectively. The measurements were carried out for 85Rb atoms in natural isotopic composition using pump–probe spectroscopy. The studies will have useful application in measurements of relaxation rates, quantum memory, quantum repeaters and atomic devices.

arXiv:2201.13009•Journal of Physics B Atomic Molecular and Optical Physics•Jun 28, 2022•5 citations
The processes of synchronous Zeeman's relaxation are investigated with simultaneous observing population difference, Mz(τ1) — and coherence, Mx(τ2), — components within a spin of system of87Rb atoms in cells with antirelaxation coating, when changing cell volume, operating temperature and pumping light intensity with D1— line. The existence of total relaxation ‘degeneracy’ is experimentally determined which is characterized through (t1≈ t2) — condition being necessary [1] for achieving a high long-term frequency stability of standards (in particular, quantum magnetometers). The procedure for investigating relaxation processes developed by the author could be useful for the realization of atomic frequency standards with a high long-term frequency stability.
Using laser optical pumping, widths and frequency shifts are determined for microwave transitions between ground-state hyperfine components of 85Rb^{85}\mathrm{Rb}85Rb and 87Rb^{87}\mathrm{Rb}87Rb atoms contained in vapor cells with alkane antirelaxation coatings. The results are compared with data on Zeeman relaxation obtained in nonlinear magneto-optical rotation experiments, a comparison important for quantitative understanding of spin-relaxation mechanisms in coated cells. By comparing cells manufactured over a $40\text{\penalty1000-\hskip0pt}\text{year}$ period we demonstrate the long-term stability of coated cells, an important property for atomic clocks and magnetometers.
The results of studies of the long-term frequency stability as a function of the correlation coefficient for a tandem of two quantum magnetometers with laser pumping of 87 Rb in wall-coated vapour cell are represented. Measurement scheme includes a low-frequency self-generating magnetometer and a quantum microwave discriminator working at magnetic dipole transitions of radio-optical end state resonance. The difference of synchronously detected signals is processed to determine the Allan variance as a function of averaging time and correlation coefficient of signals. These parameters are essentially dependent both on the pumping light intensity and polarization and the intensity of radio fields that are produced in the working cell.
An alkene-based antirelaxation coating for alkali-metal vapor cells exhibiting Zeeman relaxation times up to 77 s was recently identified by Balabas et al. The long relaxation times, two orders of magnitude longer than in paraffin- (alkane-) coated cells, motivate revisiting the question of what the mechanism is underlying wall-collision-induced relaxation and renew interest in applications of alkali-metal vapor cells to secondary frequency standards. We measure the width and frequency shift of the ground-state hyperfine $m{}_{F}=0\ensuremath{\rightarrow}m{}_{F}^{\ensuremath{'}}=0$ transition (clock resonance) in vapor cells with 85{}^{85}85Rb and 87{}^{87}87Rb atoms, with an alkene antirelaxation coating. We find that the frequency shift is slightly larger than for paraffin-coated cells and that the Zeeman linewidth scales linearly with the hyperfine frequency shift.
Vapor cells with antirelaxation coating are widely used in modern atomic physics experiments due to the coating's ability to maintain the atoms' spin polarization during wall collisions. We characterize the performance of vapor cells with different coating materials by measuring longitudinal spin relaxation and vapor density at temperatures up to 95 °C. We infer that the spin-projection-noise-limited sensitivity for atomic magnetometers with such cells improves with temperature, which demonstrates the potential of antirelaxation coated cells in applications of future high-sensitivity magnetometers.
The possibility of the atomic clock based on two quantum magnetometer system development is demonstrated. One of the magnetometers is self-oscillation type, another is M z - type magnetometer based on end-state UHF resonance. The laser pumping of 87 Rb atoms placed into antirelaxation coated sell is provided. The magnetometers frequency difference fluctuations experimental results are represented and Allan deviation is determined. The role of the radio-optical resonance frequency light shift different components is denoted for the determination of the quantum magnetometers optimal operation mode. The effect of the light shift compensation is demonstrated.
Abstract Precise control and knowledge over atomic dynamics is central to the advancement of quantum technology. The different experimental conditions namely, atoms in a vacuum, antirelaxation coated and buffer gas filled atomic cells provide complementary platforms for such investigations. The extent of changes in optical pumping, velocity changing collision and hyperfine changing collision rates associated with these conditions are discussed. There is a phenomenal change in the optical density by a factor of >25 times in the presence of a control field in a buffer gas environment. We found confinement induced enhanced optical pumping as the mechanism behind the observed transparency in buffer gas cell. The diffusive velocity of atoms were measured to be ∼25 ± 12 m s−1 and ⩽8 ± 4 m s−1 for antirelaxation coated and buffer gas filled cells respectively. The measurements were carried out for 85Rb atoms in natural isotopic composition using pump–probe spectroscopy. The studies will have useful application in measurements of relaxation rates, quantum memory, quantum repeaters and atomic devices.