Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

DC voltage calibrator based on an array of high-temperature superconductor josephson junctions

Alexander M. Klushin, A.V. Komkov, V.D. Gelikonova, S. I. Borovitskii, M. Siegel

Published Apr 1, 2003• 7 citations
Publisher

Abstract

We have developed and investigated the main parts of a voltage calibrator with an output voltage up to 10 V. The calibrator is based on a quantum DC voltage which is generated by an array of high-temperature superconductor Josephson junctions. The described concept and the demonstrated parameters of the main parts of the instrument show, that a combined uncertainty of the output voltage of a few parts in 10/sup 8/ can be obtained.

DOI
10.1109/tim.2003.811581

Related papers

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations

A modular and customizable open-source package for quantum voltage standards operation and control

Paolo Durandetto, A. Sosso

This paper presents an open-source package developed in Python that controls and drives a programmable Josephson array to synthesize dc and ac quantum-accurate voltages. Programmable arrays are devices subdivided into independent subsections, each counting a number of series connected Josephson junctions that follows a binary sequence (1, 2, 4, 8, …) to control the output voltage. Our software allows to independently measure the current-voltage characteristics of each subsection by means of a set of arbitrary waveform generators and a nanovoltmeter that measures the voltage across the whole array with high sensitivity. A quantization test tool is also provided to check with sub-microvolt resolution whether the array is operating on its quantum margins. The code is modular and easily expandable with the support of many libraries, allowing prompt reconfiguration for different calibration and testing purposes. It is aimed at being a starting point for cooperation between National Metrology Institutes towards the realization of a shared quantum voltage calibration infrastructure.

PLoS ONE•Dec 17, 2018•3 citations

Josephson waveform synthesizers

J. Niemeyer, Oliver Kieler, F. Muller +3 more

The DC voltage across a Josephson junction is exactly determined by the number of single flux quanta Φ0passing the junction per second. By locking this flux train to an external sinusoidal microwave with the frequency f or a pulse train with the pulse rate f in such a way that one flux quantum is transferred per microwave period or per pulse respectively, the junction DC voltage becomes V=Φ0f in the simplest case. The precision of V is only determined by the uncertainty of the frequency control. As the output voltage is relatively small (V=140μV for f=70GHz), large series arrays of n Josephson junctions must be used to increase the voltage to practical levels V=nΦ0f. With a sinusoidal 70 GHz microwave drive and series arrays of up to 14000 SIS tunnel junctions modern DC voltage standards were developed in the past which may reach a reproducibility of a few parts in 10-10. These standards are commercially available and form the basis of the legal voltage metrology of most of the national laboratories worldwide. Because the reference voltages of these standards are widely overlapping it is difficult to rapidly adjust the desired voltage. It was therefore impossible to use these quantum voltmeters for the precise analysis of AC voltages. For this purpose the arrays had to be modified in many respects. The direct way to generate arbitrary Josephson waveforms V(t) is to rapidly alter the frequency f(t) with respect to the desired waveform V(t)=nf(t)Φ0. It requires a precise flux transfer control over a very wide frequency range.

International Kharkiv Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves•Jun 1, 2010•0 citations

10 V SINIS Josephson junction series arrays for programmable voltage standards

J. Kohlmann, H. Schulze, Ralf Behr +2 more

A programmable dc voltage standard for output voltages of up to 10 V has been realized. The series arrays, consisting of about 69120 overdamped superconductor/insulator/normal metal/insulator/superconductor (SINIS) Josephson junctions, have been fabricated using the reliable Nb-Al/Al/sub 2/O/sub 3/ technology. The arrays can be operated in conventional Josephson voltage standards at microwave frequencies from 70 GHz to 75 GHz. Steps of constant voltage are observed at very low microwave power levels, since the major part of the microwave power is generated by the junctions themselves. The operation of the arrays and the formation of Shapiro steps are discussed.

IEEE Transactions on Instrumentation and Measurement•Apr 1, 2001•20 citations

Applications in Quantum Metrology

J. Kohlmann, Alexander B Zorin

Famous applications of Josephson junctions have successfully been established in electrical metrology for high-precision measurements. The main important representative of a metrological application is the Josephson voltage standard initially used for dc measurements. Meanwhile, the developments are focused on Josephson voltage standards for ac applications. These quantum voltage standards for output voltages up to 10 V contain series arrays of 100,000 Josephson junctions or even more. This chapter describes the development and present status of modern Josephson voltage standards. The fundamental duality of the superconducting phase and the electric charge makes it possible to realize superconducting circuits, enabling the controlled motion of individual Cooper pairs. We review the status of these circuits, including either small Josephson junctions or superconducting nanowires, and their possible application to electrical metrology.

Applied Superconductivity•Jan 7, 2015•3 citations

Pulse-Driven High- TC Josephson Junctions for Quantum Voltage Devices

Adam C. Weis, Nathan E. Flowers-Jacobs, E.Y. Cho +6 more

Josephson junction arrays are the basis for quantum-accurate dc and ac voltage standards, including artificial voltage-noise references used in noise thermometry. I will describe our recent progress towards voltage synthesis using high-transition-temperature YBCO junctions.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•0 citations
We have developed and investigated the main parts of a voltage calibrator with an output voltage up to 10 V. The calibrator is based on a quantum DC voltage which is generated by an array of high-temperature superconductor Josephson junctions. The described concept and the demonstrated parameters of the main parts of the instrument show, that a combined uncertainty of the output voltage of a few parts in 10/sup 8/ can be obtained.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.
This paper presents an open-source package developed in Python that controls and drives a programmable Josephson array to synthesize dc and ac quantum-accurate voltages. Programmable arrays are devices subdivided into independent subsections, each counting a number of series connected Josephson junctions that follows a binary sequence (1, 2, 4, 8, …) to control the output voltage. Our software allows to independently measure the current-voltage characteristics of each subsection by means of a set of arbitrary waveform generators and a nanovoltmeter that measures the voltage across the whole array with high sensitivity. A quantization test tool is also provided to check with sub-microvolt resolution whether the array is operating on its quantum margins. The code is modular and easily expandable with the support of many libraries, allowing prompt reconfiguration for different calibration and testing purposes. It is aimed at being a starting point for cooperation between National Metrology Institutes towards the realization of a shared quantum voltage calibration infrastructure.
The DC voltage across a Josephson junction is exactly determined by the number of single flux quanta Φ0passing the junction per second. By locking this flux train to an external sinusoidal microwave with the frequency f or a pulse train with the pulse rate f in such a way that one flux quantum is transferred per microwave period or per pulse respectively, the junction DC voltage becomes V=Φ0f in the simplest case. The precision of V is only determined by the uncertainty of the frequency control. As the output voltage is relatively small (V=140μV for f=70GHz), large series arrays of n Josephson junctions must be used to increase the voltage to practical levels V=nΦ0f. With a sinusoidal 70 GHz microwave drive and series arrays of up to 14000 SIS tunnel junctions modern DC voltage standards were developed in the past which may reach a reproducibility of a few parts in 10-10. These standards are commercially available and form the basis of the legal voltage metrology of most of the national laboratories worldwide. Because the reference voltages of these standards are widely overlapping it is difficult to rapidly adjust the desired voltage. It was therefore impossible to use these quantum voltmeters for the precise analysis of AC voltages. For this purpose the arrays had to be modified in many respects. The direct way to generate arbitrary Josephson waveforms V(t) is to rapidly alter the frequency f(t) with respect to the desired waveform V(t)=nf(t)Φ0. It requires a precise flux transfer control over a very wide frequency range.
A programmable dc voltage standard for output voltages of up to 10 V has been realized. The series arrays, consisting of about 69120 overdamped superconductor/insulator/normal metal/insulator/superconductor (SINIS) Josephson junctions, have been fabricated using the reliable Nb-Al/Al/sub 2/O/sub 3/ technology. The arrays can be operated in conventional Josephson voltage standards at microwave frequencies from 70 GHz to 75 GHz. Steps of constant voltage are observed at very low microwave power levels, since the major part of the microwave power is generated by the junctions themselves. The operation of the arrays and the formation of Shapiro steps are discussed.
Famous applications of Josephson junctions have successfully been established in electrical metrology for high-precision measurements. The main important representative of a metrological application is the Josephson voltage standard initially used for dc measurements. Meanwhile, the developments are focused on Josephson voltage standards for ac applications. These quantum voltage standards for output voltages up to 10 V contain series arrays of 100,000 Josephson junctions or even more. This chapter describes the development and present status of modern Josephson voltage standards. The fundamental duality of the superconducting phase and the electric charge makes it possible to realize superconducting circuits, enabling the controlled motion of individual Cooper pairs. We review the status of these circuits, including either small Josephson junctions or superconducting nanowires, and their possible application to electrical metrology.