Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Study of coherent population trapping occurring in 87Rb atoms contained in wall-coated cells

Evelina Breschi, G. Mileti

Published Apr 1, 2009• 1 citation
Publisher

Abstract

We report on the continuous CPT-interrogation of87Rb atoms contained in a paraffin wall-coated cell. Based on the signal-to-noise measurements we predict a short-term stability better than 10-12tau-1/2. This result confirms the interest on wall-coated cells for applications in high performance and compact vapor cell atomic clocks. We also report on our results on the influence of the cell temperature in the clock signal which has not be studied in this specific case as far as we know.

DOI
10.1109/freq.2009.5168243

Related papers

Investigations on continuous and pulsed interrogation for a CPT atomic clock

N. Castagna, Rodolphe Boudot, Stéphane Guérandel +3 more

We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Feb 1, 2009•65 citations

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan +3 more

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

Chinese Physics B•Oct 6, 2021•8 citations

Atomic clock using coherent population trapping in a cesium cell: frequency stability and limitations

Sinda Mejri, François Tricot, Jean-Marie Danet +3 more

Toward the next generation of compact devices, atomic clocks based on coherent population trapping (CPT) offer a very interesting alternative. We present a review of our studies on the short and mid term stability of a compact high performance atomic clock based on CPT in view of portable applications.

Journal of Physics Conference Series•Jun 1, 2016•4 citations

Light shift of Double Resonance and Coherent Population Trapping in wall-coated cells for compact Rb clocks

D. Miletic, Thejesh Bandi, C. Affolderbach +1 more

We report on a comparative study on the light shift in two possible clock schemes for vapor-cell standards, Double Resonance (DR) and Coherent Population Trapping (CPT), by using the same wall coated cell and compact atomic resonator. Our experimental setup allowed us to measure and study the AC Stark shift, resulting from a mono-chromatic or a non monochromatic optical excitation. The light-shift was investigated as function of the laser intensity and the laser frequency.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•0 citations

Ramsey effect of coherent population trapping in anti-relaxation-coated Rb vapor cells

Hyun Joon Lee, Han Seb Moon

We examine experimentally and theoretically the Ramsey effects on the coherent population trapping (CPT) resonance in a paraffin-coated Rb vapor cell. The observed CPT spectrum in the Hanle configuration of the 5S 1/2(F = 2)−5P 1/2(F′ = 1) transition of 87Rb atoms consists of a narrow structure with a spectral width of 0.10 mG due to the wall-induced Ramsey effect and a broad structure with a spectral width of 23 mG due to the transit effect. Considering the velocity distribution of atoms and the number of wall-atom collisions, we numerically calculated the transmittance of the laser beam as a function of the longitudinal magnetic field. The experimental results of the CPT Ramsey interference were in good agreement with the theoretical results, and the dependences of the CPT Ramsey effects on the atom-laser interaction time were investigated in detail.

Journal of the Korean Physical Society•Aug 1, 2013•5 citations

Stability properties of an Rb CPT atomic clock with buffer-gas-free cells under dynamic excitation

Sergey M Kobtsev, Daba A. Radnatarov, Sergey Khripunov +3 more

This work presents a study of the short-term stability properties of Rb atomic clocks based on coherent population trapping (CPT) under dynamic excitation of a CPT resonance in cells without buffer gas. It is demonstrated that in an optical cell with anti-relaxation coating of its inner walls, the best stability is achieved at the scanning frequency of the frequency difference of the bichromatic pump field equal to 2 kHz at the resonance width of 450 Hz. In cells without a wall coating, the optimal scanning frequency range is found to be 1.2–2.8 kHz at the resonance width of 29 kHz. Examination of the slope of the stabilization system’s discriminant curve at zero error signal for buffer-gas-free cells uncovered an amount of correlation between the discriminant curve slope and atomic clock stability. It is demonstrated that the highest stability of atomic clocks in dynamic excitation mode is achieved at a ratio of scanning frequency and amplitude around 1.

Journal of the Optical Society of America B•Sep 6, 2019•15 citations
We report on the continuous CPT-interrogation of87Rb atoms contained in a paraffin wall-coated cell. Based on the signal-to-noise measurements we predict a short-term stability better than 10-12tau-1/2. This result confirms the interest on wall-coated cells for applications in high performance and compact vapor cell atomic clocks. We also report on our results on the influence of the cell temperature in the clock signal which has not be studied in this specific case as far as we know.
We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.
We examine experimentally and theoretically the Ramsey effects on the coherent population trapping (CPT) resonance in a paraffin-coated Rb vapor cell. The observed CPT spectrum in the Hanle configuration of the 5S 1/2(F = 2)−5P 1/2(F′ = 1) transition of 87Rb atoms consists of a narrow structure with a spectral width of 0.10 mG due to the wall-induced Ramsey effect and a broad structure with a spectral width of 23 mG due to the transit effect. Considering the velocity distribution of atoms and the number of wall-atom collisions, we numerically calculated the transmittance of the laser beam as a function of the longitudinal magnetic field. The experimental results of the CPT Ramsey interference were in good agreement with the theoretical results, and the dependences of the CPT Ramsey effects on the atom-laser interaction time were investigated in detail.
This work presents a study of the short-term stability properties of Rb atomic clocks based on coherent population trapping (CPT) under dynamic excitation of a CPT resonance in cells without buffer gas. It is demonstrated that in an optical cell with anti-relaxation coating of its inner walls, the best stability is achieved at the scanning frequency of the frequency difference of the bichromatic pump field equal to 2 kHz at the resonance width of 450 Hz. In cells without a wall coating, the optimal scanning frequency range is found to be 1.2–2.8 kHz at the resonance width of 29 kHz. Examination of the slope of the stabilization system’s discriminant curve at zero error signal for buffer-gas-free cells uncovered an amount of correlation between the discriminant curve slope and atomic clock stability. It is demonstrated that the highest stability of atomic clocks in dynamic excitation mode is achieved at a ratio of scanning frequency and amplitude around 1.