Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Fourth-order interference technique for determining the coherence time of a light beam

Z. Y. Ou, E. C. Gage, Brian E. Magill, L. Mandeļ

Published Jan 1, 1989• 65 citations
Publisher

Abstract

A new experimental procedure for determining the (second-order) coherence time of a light beam is described that is based on a combination of conventional interferometry with an intensity-correlation technique. It permits measurements of coherence times that are several orders of magnitude shorter than the resolving times of the detectors, which ordinarily limit correlation measurements. The validity of the method is demonstrated by an experiment in which the transverse fluorescent light from a dye laser is measured.

DOI
10.1364/josab.6.000100

Related papers

Measurement of coherence time by fourth-order Interference

Z. Y. Ou, E. C. Gage, Brian E. Magill +1 more

By using an intensity correlation, or photon coincidence, technique and a Mach-Zehnder interferometer with artificially applied phase fluctuations in one arm, we measured the coherence time of a thermal light beam. The light was derived from the filtered fluorescence of a rhodamine 6G dye solution. The two-photon coincidence rate was measured as a function of path difference and was found to dip 50% when the two arms of the interferometer are balanced. The coherence time of ~100 fs is determined from the measured width of the dip and is consistent with the passband of the filters. The method does not require the stability needed in second-order interference measurements, and its time resolution can be much shorter than that of the photodetectors. The theory of this type of fourth-order interference technique is discussed.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Two-Photon Interference Measurement of Ultrafast Laser Pulses

Masaya Matsuoka, Y. Miyamoto, T. Kuga +2 more

Recently some novel two-photon interference experiments have been performed, where quantities such as the field coherence time and the beat spacing between light beams with different frequencies were measured with high time resolution1. These experiments have overcome the traditional limits on time resolution by combining a Mach-Zehnder interferometer configuration with the two-photon correlation technique. All of these experiments, however, have been performed with cw light sources, and no attempt has yet been made to measure the temporal variation of the field intensity.

International Conference on Ultrafast Phenomena•Jan 1, 1992•0 citations

Unbalanced fourth-order interference beyond coherence time

Z. Y. Ou, Xiaoying Li

Interferometry has been used widely in sensing application. However, the technique is limited by the finite coherence time of the light sources when the interference paths are not balanced. Higher-order interference effects involve intensity correlations between multiple detectors and may have the advantage over the traditional second-order interference effect exhibited in only one detector. We discuss various scenarios with unbalanced delays in different paths in fourth-order interference exhibited in coincidence between two detectors. We find, in some cases, interference effect persists even when the delays are much larger than the coherence time of the sources. We also extend the discussion to nonstationary pulsed fields, which need to consider the pulse shape and require a different treatment. These results will be useful in remote sensing applications.

arXiv:2111.02107•Physical Review Research•May 16, 2022•12 citations

Measurement of Fourth-Order Coherence Functions

Mark J. Beran, John B. DeVelis, George B. Parrent

In this paper we outline a method which allows one, in principle, to measure $〈{E}_{i}({\mathrm{x}}_{1}, t){E}_{j}({\mathrm{x}}_{2}, t){{E}_{k}}^{*}({\mathrm{x}}_{3}, t)\ifmmode\times\else\texttimes\fi{}{{E}_{l}}^{*}({\mathrm{x}}_{4}, t)〉$ (in general, ${\mathbf{x}}_{1}$\ensuremath{\ne}${\mathbf{x}}_{2}$\ensuremath{\ne}${\mathbf{x}}_{3}$\ensuremath{\ne}${\mathbf{x}}_{4}$), for stationary quasimonochromatic light propagating principally in the forward direction. The procedure makes use of the properties of nonlinear dielectrics in a sequence of interference experiments. No correlation of photoelectron currents is used, and as a special case the contracted moment $〈{|{E}_{i}({\mathrm{x}}_{1}, t)|}^{2}{|{E}_{j}({\mathrm{x}}_{2}, t)|}^{2}〉$ measured by Hanbury Brown and Twiss could be obtained in this manner. It is shown that it should be possible to measure the full fourth-order coherence function in the laboratory for laser light, using presently obtainable intensity levels.

Physical Review•Feb 25, 1967•8 citations

Coherence time measurements using a single detector with variable time resolution

Marc Aßmann, M. Bayer

We present a simple technique for measuring coherence times for stationary light fields using a single detector with tunable time resolution. By measuring the equal-time second-order correlation function at varying instrument response functions it is possible to determine the coherence time and also the shape of the temporal decay without the need to record time-resolved data. The technique is demonstrated for pseudothermal light. Possible applications for dynamic light scattering and photon statistics measurements are discussed.

Optics Letters•Jul 4, 2012•6 citations

Quantum-inspired distance sensing using thermal light second-order interference

Francesco Vincenzo Pepe, Gabriele Chilleri, Giovanni Scala +3 more

We introduce and describe a technique for distance sensing, based on second-order interferometry of thermal light. The method is based on measuring correlation between intensity fluctuations on two detectors, and provides estimates of the distances separating a remote mask from the source and the detector, even when such information cannot be retrieved by first-order intensity measurements. We show how the sensitivity to such distances is intimately connected to the degree of correlation of the measured interference pattern in different experimental scenarios and independently of the spectral properties of light. Remarkably, this protocol can be also used to measure the distance of remote reflective objects in the presence of turbulence. We demonstrate the emergence of new critical parameters which benchmark the degree of second order correlation, describing the counterintuitive emergence of spatial second-order interference not only in the absence of (first-order) coherence at both detectors but also when first order interference is observed at one of the two detectors.

•Nov 10, 2020•1 citation
A new experimental procedure for determining the (second-order) coherence time of a light beam is described that is based on a combination of conventional interferometry with an intensity-correlation technique. It permits measurements of coherence times that are several orders of magnitude shorter than the resolving times of the detectors, which ordinarily limit correlation measurements. The validity of the method is demonstrated by an experiment in which the transverse fluorescent light from a dye laser is measured.
By using an intensity correlation, or photon coincidence, technique and a Mach-Zehnder interferometer with artificially applied phase fluctuations in one arm, we measured the coherence time of a thermal light beam. The light was derived from the filtered fluorescence of a rhodamine 6G dye solution. The two-photon coincidence rate was measured as a function of path difference and was found to dip 50% when the two arms of the interferometer are balanced. The coherence time of ~100 fs is determined from the measured width of the dip and is consistent with the passband of the filters. The method does not require the stability needed in second-order interference measurements, and its time resolution can be much shorter than that of the photodetectors. The theory of this type of fourth-order interference technique is discussed.
Recently some novel two-photon interference experiments have been performed, where quantities such as the field coherence time and the beat spacing between light beams with different frequencies were measured with high time resolution1. These experiments have overcome the traditional limits on time resolution by combining a Mach-Zehnder interferometer configuration with the two-photon correlation technique. All of these experiments, however, have been performed with cw light sources, and no attempt has yet been made to measure the temporal variation of the field intensity.
Interferometry has been used widely in sensing application. However, the technique is limited by the finite coherence time of the light sources when the interference paths are not balanced. Higher-order interference effects involve intensity correlations between multiple detectors and may have the advantage over the traditional second-order interference effect exhibited in only one detector. We discuss various scenarios with unbalanced delays in different paths in fourth-order interference exhibited in coincidence between two detectors. We find, in some cases, interference effect persists even when the delays are much larger than the coherence time of the sources. We also extend the discussion to nonstationary pulsed fields, which need to consider the pulse shape and require a different treatment. These results will be useful in remote sensing applications.
In this paper we outline a method which allows one, in principle, to measure $〈{E}_{i}({\mathrm{x}}_{1}, t){E}_{j}({\mathrm{x}}_{2}, t){{E}_{k}}^{*}({\mathrm{x}}_{3}, t)\ifmmode\times\else\texttimes\fi{}{{E}_{l}}^{*}({\mathrm{x}}_{4}, t)〉$ (in general, x1{\mathbf{x}}_{1}x1​\ensuremath{\ne}x2{\mathbf{x}}_{2}x2​\ensuremath{\ne}x3{\mathbf{x}}_{3}x3​\ensuremath{\ne}x4{\mathbf{x}}_{4}x4​), for stationary quasimonochromatic light propagating principally in the forward direction. The procedure makes use of the properties of nonlinear dielectrics in a sequence of interference experiments. No correlation of photoelectron currents is used, and as a special case the contracted moment 〈∣Ei(x1,t)∣2∣Ej(x2,t)∣2〉〈{|{E}_{i}({\mathrm{x}}_{1}, t)|}^{2}{|{E}_{j}({\mathrm{x}}_{2}, t)|}^{2}〉〈∣Ei​(x1​,t)∣2∣Ej​(x2​,t)∣2〉 measured by Hanbury Brown and Twiss could be obtained in this manner. It is shown that it should be possible to measure the full fourth-order coherence function in the laboratory for laser light, using presently obtainable intensity levels.
We present a simple technique for measuring coherence times for stationary light fields using a single detector with tunable time resolution. By measuring the equal-time second-order correlation function at varying instrument response functions it is possible to determine the coherence time and also the shape of the temporal decay without the need to record time-resolved data. The technique is demonstrated for pseudothermal light. Possible applications for dynamic light scattering and photon statistics measurements are discussed.
We introduce and describe a technique for distance sensing, based on second-order interferometry of thermal light. The method is based on measuring correlation between intensity fluctuations on two detectors, and provides estimates of the distances separating a remote mask from the source and the detector, even when such information cannot be retrieved by first-order intensity measurements. We show how the sensitivity to such distances is intimately connected to the degree of correlation of the measured interference pattern in different experimental scenarios and independently of the spectral properties of light. Remarkably, this protocol can be also used to measure the distance of remote reflective objects in the presence of turbulence. We demonstrate the emergence of new critical parameters which benchmark the degree of second order correlation, describing the counterintuitive emergence of spatial second-order interference not only in the absence of (first-order) coherence at both detectors but also when first order interference is observed at one of the two detectors.