AIP conference proceedings
First Attempts at Antihydrogen Trapping in ALPHA
Gorm Bruun Andresen, William Alan Bertsche, Paul David Bowe, C. C. Bray, E. Butler, Claudio Lenz Cesar, S. Chapman, M. Charlton, J. Fajans, M. Fujiwara, R. Funakoshi, David Russell Gill, Jeff S. Hangst, W. N. Hardy, R. Hayano, M. E. Hayden, Andrew James Humphries, Richard Hydomako, M. J. Jenkins, L. V. Jørgensen, L. L. Kurchaninov, Ricardo Lewis Lambo, N. Madsen, Paul J. Nolan, K. Olchanski, Art Olin, Robert D. Page, Alexander P. Povilus, Petteri Pusa, F. Robicheaux, E. Sarid, S. Seif El Nasr, Daniel Miranda Silveira, James William Storey, R. I. Thompson, Dirk Peter van der Werf, Jonathan Syrkin Wurtele, Y. Yamazaki, Yasuyuki Kanai, Y. Yamazaki
Abstract
The ALPHA apparatus is designed to produce and trap antihydrogen atoms. The device comprises a multifunction Penning trap and a superconducting, neutral atom trap having a minimum‐B configuration. The atom trap features an octupole magnet for transverse confinement and solenoidal mirror coils for longitudinal confinement. The magnetic trap employs a fast shutdown system to maximize the probability of detecting the annihilation of released antihydrogen. In this article we describe the first attempts to observe antihydrogen trapping.