Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Comment on NOTES ON THE THEORY OF QUANTUM CLOCK

Dariusz Wciso

Published Jan 1, 2005• 0 citations
OpenAlex

Related papers

Time in Quantum Mechanics II

Juan Gonzalo Muga, A. Ruschhaupt, A Del Campo

Lecture notes in physics•Jan 1, 2009•110 citations

Comment on "Entropic Costs of Extracting Classical Ticks from a Quantum Clock"

Longyan Gong

A recent Letter by Wadhia et al. reports a realization of a quantum clock using a double quantum dot (DQD) [Phys. Rev. Lett. 135, 200407 (2005)]. This Comment identifies two fundamental issues: (I) the claimed ``quantum clock" exhibits only classical behavior and lacks intrinsic temporal correlations between ticks; it is not sufficient for accurate time as a good clock. (II) the thermodynamic analysis misassigns entropy production and conflates amplification with measurement; the reported combined entropy is an engineering dissipation, not a fundamental cost of quantum timekeeping.

cond-mat.mes-hallCross-listedarXiv:2605.21833•May 22, 2026•0 citations

NOTES ON THE THEORY OF QUANTUM CLOCK

Igor E. Tralle, Juha-Pekka Pellonpää

In this paper we argue that the notion of time, whatever complicated and difficult to define as the philosophical cat-egory, from physicist’s point of view is nothing else but the sum of ’lapses of time ’ measured by a proper clock. As far as Quantum Mechanics is concerned, we distinguish a special class of clocks, the ’atomic clocks’. It is because at atomic and subatomic level there is no other possibility to construct a ’unit of time ’ or ’instant of time ’ as to use the quantum transitions between chosen quantum states of a quantum ob-ject such as atoms, atomic nuclei and so on, to imitate the periodic circular motion of a clock hand over the dial. The clock synchronization problem is also discussed in the paper. We study the problem of defining a time difference observable for two-mode oscillator system. We assume that the time dif-ference obsevable is the difference of two single-mode covariant Concepts of Physics, Vol. II (2005) 113 time observables which are represented as a time shift covari-ant normalized positive operator measures. The difficulty of finding the correct value space and normalization for time dif-ference is discussed. 114 Concepts of Physics, Vol. II (2005) Notes on the Theory of Quantum Clock And the heaven departed as a scroll when it is rolled together;... And sware by him that liveth for ever and ever, who created heaven, and the things that therein are, and earth and the things that therein, and the sea, and the things which are therein, that THERE SHOULD

•Jan 1, 2005•1 citation

Time in Quantum Theory

H. D. Zeh

Springer eBooks•Jan 1, 2009•14 citations

Time in the quantum world

Institute of Physics eBooks•Nov 26, 2004•0 citations

Comment on "Ideal clocks -- a convenient fiction" by K. Lorek et al

Vladimir Toussaint

We correct a subtle oversight in Eq.(19) of K. Lorek et al. [Class. Quantum Grav. 32 175003 (2015)] concerning the decay probability of a uniformly accelerated quantum clock. The original expression included unphysical cross-wedge term ($|\barγ_{K 1}|^2$) violating the spatial separation of Rindler wedges. We derive the corrected probability using the paper's Rindler conformal coordinates $(τ, ξ)$, retaining only causally consistent thermal terms, and discuss implications for relativistic clock models.

quant-pharXiv:2607.00059•Jul 1, 2026
A recent Letter by Wadhia et al. reports a realization of a quantum clock using a double quantum dot (DQD) [Phys. Rev. Lett. 135, 200407 (2005)]. This Comment identifies two fundamental issues: (I) the claimed ``quantum clock" exhibits only classical behavior and lacks intrinsic temporal correlations between ticks; it is not sufficient for accurate time as a good clock. (II) the thermodynamic analysis misassigns entropy production and conflates amplification with measurement; the reported combined entropy is an engineering dissipation, not a fundamental cost of quantum timekeeping.
In this paper we argue that the notion of time, whatever complicated and difficult to define as the philosophical cat-egory, from physicist’s point of view is nothing else but the sum of ’lapses of time ’ measured by a proper clock. As far as Quantum Mechanics is concerned, we distinguish a special class of clocks, the ’atomic clocks’. It is because at atomic and subatomic level there is no other possibility to construct a ’unit of time ’ or ’instant of time ’ as to use the quantum transitions between chosen quantum states of a quantum ob-ject such as atoms, atomic nuclei and so on, to imitate the periodic circular motion of a clock hand over the dial. The clock synchronization problem is also discussed in the paper. We study the problem of defining a time difference observable for two-mode oscillator system. We assume that the time dif-ference obsevable is the difference of two single-mode covariant Concepts of Physics, Vol. II (2005) 113 time observables which are represented as a time shift covari-ant normalized positive operator measures. The difficulty of finding the correct value space and normalization for time dif-ference is discussed. 114 Concepts of Physics, Vol. II (2005) Notes on the Theory of Quantum Clock And the heaven departed as a scroll when it is rolled together;... And sware by him that liveth for ever and ever, who created heaven, and the things that therein are, and earth and the things that therein, and the sea, and the things which are therein, that THERE SHOULD
We correct a subtle oversight in Eq.(19) of K. Lorek et al. [Class. Quantum Grav. 32 175003 (2015)] concerning the decay probability of a uniformly accelerated quantum clock. The original expression included unphysical cross-wedge term (∣γˉK1∣2|\barγ_{K 1}|^2∣γˉ​K1​∣2) violating the spatial separation of Rindler wedges. We derive the corrected probability using the paper's Rindler conformal coordinates (τ,ξ)(τ, ξ)(τ,ξ), retaining only causally consistent thermal terms, and discuss implications for relativistic clock models.