Quantum Electronics and Laser Science Conference

Correlation and fluctuation features of a triply resonant OPO far above threshold

A. Porzio, Fabio Sciarrino, A. Chiummo, S. Solimeno

Published Nov 13, 2002• 0 citations
Publisher

Abstract

Summary form only given. Continuous-wave twin beams, generated in cw optical parametric oscillators (OPO), show intensity difference quantum noise reduction. So far the reported measurements concern OPO operating with pump powers close to the threshold (P/P/sub th/13.
DOI
10.1109/qels.2001.961780

Related papers

Single-beam noise characteristics of quantum-correlated twin beams

Yun Zhang, Katsuyuki Kasai, Kazuhiro Hayasaka

We investigated the intensity noise spectra of a single beam of a pump-enhanced continuous-wave optical parametric oscillator (OPO), which was used to generate quantum-correlated twin beams, as a function of the pump power. With a triply (pump-, signal-, and idler-) resonant cavity, the oscillation threshold of our OPO was 8.5±1.3 mW and the measured slope conversion efficiency was 0.72±0.02. Twin beams with a power of 240 mW were generated at a pump power of 350 mW. The relaxation oscillation frequencies, which depend on the pump power, were observed when the pump power of the OPO was 12.5–28 mW. The experimental results confirm the predicted increase in OPO relaxation frequency with pump power. We experimentally inferred squeezing of the single-beam intensity, for the first time to our knowledge, by exploiting the nature of quantum noise that is dependent on loss.

arXiv:quant-ph/0402119•Journal of the Optical Society of America B•Apr 29, 2004•12 citations

Observation of Quantum Noise Reduction on Twin Laser Beams

A. Heidmann, R. J. Horowicz, Serge Reynaud +3 more

We have used a two-mode optical parametric oscillator operating above threshold to generate high-intensity twin beams which exhibit quantum correlations. The noise power measured on the intensity difference between two such beams is reduced by 30% below the shot-noise limit. Noise reduction is observed over a broad range of frequencies.

Physical Review Letters•Nov 30, 1987•632 citations

Twin-beam generation in a triply resonant dual-cavity optical parametric oscillator

Joseph Teja, N. C. Wong

We demonstrate a low-threshold twin-beam generator using a cw triply resonant optical parametric oscillator consisting of two coupled cavities: one that resonates the signal and idler waves and the other the pump field. An intensity correlation of 5.5 dB was observed at 3 MHz for a type-II phase-matched KTP optical parametric oscillator.

Optics Express•Feb 2, 1998•23 citations

Improvements in the observed intensity correlation of optical parametric oscillator twin beams

Jerome C. Mertz, Thierry Debuisschert, A. Heidmann +2 more

We report an observed quantum noise reduction of 86% (8.5 dB) near 3 MHz in the intensity difference between the twin beams generated by a nondegenerate type II optical parametric oscillator operating above threshold.

Optics Letters•Aug 15, 1991•108 citations

Sub-shot-noise high-sensitivity spectroscopy with optical parametric oscillator twin beams

P. H. Souto Ribeiro, Catherine Schwob, Agnès Maître +1 more

Nondegenerate optical parametric oscillators generate above-threshold signal and idler beams that have intensity fluctuations correlated at the quantum level (twin beams). We describe what is to our knowledge the first high-sensitivity spectroscopy experiment using twin beams emitted by a cw optical parametric oscillator: a very weak two-photon absorption signal, in the 10(-7) range, is recorded on the 4S(1/2)-5S(1/2) transition of atomic potassium with a noise background that is reduced by 1.9 dB with respect to the shot-noise limit of the light used in the experiment.

Optics Letters•Dec 15, 1997•117 citations

Photon noise reduction by optoelectronic correction using a nondegenerate optical parametric oscillator

Claude Fabre, Jerome C. Mertz, E. Giacobino +2 more

It has been recently shown theoretically1 and experimentally2 that nondegenerate optical parametric oscillators generate above threshold intense and highly correlated twin beams. More precisely, the noise on the difference between the intensities of the two beams is well below the shot noise for noise frequencies inside the cavity bandwidth. An application of this quantum correlation is to measure the intensity of one beam and use this information to correct the fluctuations of the other beam by optoelectronic means (photodiode, amplifier, and electrooptic modulator). The correction may be applied either on the pumping beam (feedback correction) or directly on the twin beam itself (feed-forward correction).

Annual Meeting Optical Society of America•Jan 1, 1989•0 citations
We investigated the intensity noise spectra of a single beam of a pump-enhanced continuous-wave optical parametric oscillator (OPO), which was used to generate quantum-correlated twin beams, as a function of the pump power. With a triply (pump-, signal-, and idler-) resonant cavity, the oscillation threshold of our OPO was 8.5±1.3 mW and the measured slope conversion efficiency was 0.72±0.02. Twin beams with a power of 240 mW were generated at a pump power of 350 mW. The relaxation oscillation frequencies, which depend on the pump power, were observed when the pump power of the OPO was 12.5–28 mW. The experimental results confirm the predicted increase in OPO relaxation frequency with pump power. We experimentally inferred squeezing of the single-beam intensity, for the first time to our knowledge, by exploiting the nature of quantum noise that is dependent on loss.
Nondegenerate optical parametric oscillators generate above-threshold signal and idler beams that have intensity fluctuations correlated at the quantum level (twin beams). We describe what is to our knowledge the first high-sensitivity spectroscopy experiment using twin beams emitted by a cw optical parametric oscillator: a very weak two-photon absorption signal, in the 10(-7) range, is recorded on the 4S(1/2)-5S(1/2) transition of atomic potassium with a noise background that is reduced by 1.9 dB with respect to the shot-noise limit of the light used in the experiment.
It has been recently shown theoretically1 and experimentally2 that nondegenerate optical parametric oscillators generate above threshold intense and highly correlated twin beams. More precisely, the noise on the difference between the intensities of the two beams is well below the shot noise for noise frequencies inside the cavity bandwidth. An application of this quantum correlation is to measure the intensity of one beam and use this information to correct the fluctuations of the other beam by optoelectronic means (photodiode, amplifier, and electrooptic modulator). The correction may be applied either on the pumping beam (feedback correction) or directly on the twin beam itself (feed-forward correction).