Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica Scripta

On the numerical calculation of the micromaser spectrum

F. De Zela

Published Dec 1, 1995• 2 citations
Publisher

Abstract

A powerful numerical algorithm is described for calculating the micromaser spectrum. The method can be extended as a tool for computing the dynamics of the field density matrix which describes the photon field inside the micromaser cavity. An expression for the micromaser spectrum is also discussed, from which the role played by the initial state in the build-up of the spectrum becomes clearly distinguished from the micromaser dynamics.

DOI
10.1088/0031-8949/52/6/011

Related papers

Micromaser with injected atomic phase

Rebecca R. McGowan, William C. Schieve

Both approximate and exact methods exist to determine the density matrix of the field inside an incoherently driven micromaser, but as of yet only a steady-state Fokker-Planck solution has been found for the micromaser with injected atomic phase [Phys. Rev. A 34, 2032 (1986)]. Since Fokker-Planck solutions have been shown not to represent the effect of trapping states on the cavity field adequately, other solutions must be sought. In this paper, we present both a highly accurate approximate analytical solution and a more computationally complex numerical solution based on the exact methods of Lu [Phys. Rev. A 47, 1347 (1993)], both of which demonstrate symmetry breaking in the phase. Since the spectra of the injected phase micromaser will be the same as that of the incoherently pumped case, we present numerical comparisons of our two solutions via the phase variance.

Physical Review A•Sep 1, 1997•11 citations

Field-State Retrodiction in a Micromaser

E.-K. Tan

We have used retrodictive quantum theory to calculate the retrodictive initial field states of a micromaser for different combinations of prepared and measured atomic states. This method allows calculations of both the photon statistics and the off‐diagonal matrix elements, thus the phase information, of the cavity field prior to interaction with injected atoms.

AIP conference proceedings•Jan 1, 2004•0 citations

Micromaser linewidth

Rebecca R. McGowan, William C. Schieve

In earlier papers, the linewidth of a micromaser was approximated by a phase diffusion rate that was obtained using a single decay rate assumption to model the decay of the electric field in the micromaser cavity. These methods gave analytic but approximate answers. Exact methods calculated the spectrum via the two-time correlation function, but required extensive numerical calculations. In this paper, we present an approximate analytic derivation of the micromaser spectrum via the two-time correlation function that is more accurate than other approximate analytic methods yet requires much less numerical calculation than the exact methods. We also review the other methods, both analytical and exact, and present numerical comparisons.

Physical Review A•May 1, 1997•8 citations

Time-dependent micromaser spectrum

Bimalendu Deb, Deb Shankar Ray

We examine the growth of a cavity field built up from a vacuum in a micromaser in terms of a ``physical spectrum'' or a time-dependent spectrum and the photon distributions. We find that the photon distribution attains the steady state earlier than the spectrum becomes steady. The short-time decrease of the half-width at half maximum of the spectrum obeys a power-law behavior with time.

Physical Review A•Jun 1, 1994•2 citations

Micromaser spectrum

Marlan O. Scully, HERBERT WALTHER, G. S. Agarwal +2 more

We calculate the spectrum of the micromaser for a wide range of pump parameters and propose a multiple microwave field method similar to the Ramsey fringe technique to measure this spectrum. Thus it becomes possible to investigate the phase diffusion in a fundamental system such as the micromaser.

Physical Review A•Nov 1, 1991•96 citations

EXACT CALCULATIONS FOR ONE PHOTON MICROMASER WITH COHERENT INPUTS I

A. Kremid

We report a numerical simulation of the action of the one 85 Rb atom micromaser which shows that the micromaser field evolves towards a steady state equilibrium when the condition that Tp t int satisfies. In this steady state regime the cavity field reaches a steady state after a sufficient number of atoms have passed through the cavity. The cavity temperature T and the cavity quality factor Q can produce a quantitive change when one of them or the two are changed but they are not responsible for the qualitative changes in the micromaser field. Evidently the only responsible parameter for these qualitative changes is the repetition time T p namely if T p t int then the micromaser field evolution is towards a steady state equilibrium. In contrast when T p reduced to the order of t int then the micromaser field evolution is controlled by the trapping state dynamics – no steady state is apparent in this case. The first going-up trapping state at n=3 plays a significant role in the early dynamics of the micromaser field. Moreover the state of the field ultimately evolves towards a mixed state rather than a pure state.

EPH - International Journal of Applied Science•Dec 27, 2021•1 citation
A powerful numerical algorithm is described for calculating the micromaser spectrum. The method can be extended as a tool for computing the dynamics of the field density matrix which describes the photon field inside the micromaser cavity. An expression for the micromaser spectrum is also discussed, from which the role played by the initial state in the build-up of the spectrum becomes clearly distinguished from the micromaser dynamics.
Both approximate and exact methods exist to determine the density matrix of the field inside an incoherently driven micromaser, but as of yet only a steady-state Fokker-Planck solution has been found for the micromaser with injected atomic phase [Phys. Rev. A 34, 2032 (1986)]. Since Fokker-Planck solutions have been shown not to represent the effect of trapping states on the cavity field adequately, other solutions must be sought. In this paper, we present both a highly accurate approximate analytical solution and a more computationally complex numerical solution based on the exact methods of Lu [Phys. Rev. A 47, 1347 (1993)], both of which demonstrate symmetry breaking in the phase. Since the spectra of the injected phase micromaser will be the same as that of the incoherently pumped case, we present numerical comparisons of our two solutions via the phase variance.
In earlier papers, the linewidth of a micromaser was approximated by a phase diffusion rate that was obtained using a single decay rate assumption to model the decay of the electric field in the micromaser cavity. These methods gave analytic but approximate answers. Exact methods calculated the spectrum via the two-time correlation function, but required extensive numerical calculations. In this paper, we present an approximate analytic derivation of the micromaser spectrum via the two-time correlation function that is more accurate than other approximate analytic methods yet requires much less numerical calculation than the exact methods. We also review the other methods, both analytical and exact, and present numerical comparisons.
We report a numerical simulation of the action of the one 85 Rb atom micromaser which shows that the micromaser field evolves towards a steady state equilibrium when the condition that Tp t int satisfies. In this steady state regime the cavity field reaches a steady state after a sufficient number of atoms have passed through the cavity. The cavity temperature T and the cavity quality factor Q can produce a quantitive change when one of them or the two are changed but they are not responsible for the qualitative changes in the micromaser field. Evidently the only responsible parameter for these qualitative changes is the repetition time T p namely if T p t int then the micromaser field evolution is towards a steady state equilibrium. In contrast when T p reduced to the order of t int then the micromaser field evolution is controlled by the trapping state dynamics – no steady state is apparent in this case. The first going-up trapping state at n=3 plays a significant role in the early dynamics of the micromaser field. Moreover the state of the field ultimately evolves towards a mixed state rather than a pure state.