Multiconference on Electronics and Photonics (MEP)

PROGRESS AT CENAM TOWARDS A CS FOUNTAIN CLOCK

Mauricio Lopez, Eduardo De Carlos, M. Talavera-Ortega, Sergio Lopez

Published Jan 1, 2006• 1 citation
Publisher

Abstract

A primary frequency standard based on cold Cs atoms is under development at the Time and Frequency Division of the Centre Nacional de Metrologia, CENAM. A Cs magneto-optical trap has been developed using the standard sigma+sigma$4-horizontal 2-vertical laser beams of 1.9 cm in diameter, with 5 mW each. We use 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Linewidth of the master laser is 1 MHz. A 50 mW, 852 nm, semiconductor laser is used as slave laser in order to amplify the light of the master laser. The slave laser is stabilized by injection light technique. 12 MHz red shift of the light is performed by double pass through two AOM's. In this paper we present some preliminary results of our MOT characterization as function of MOT's parameters such as intensity of laser beams and gradient of the magnetic field.

DOI
10.1109/mep.2006.335642

Related papers

Accurate absolute measurement of trapped Cs atoms in a MOT

M.A. Talavera

A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrolog´ CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration (ae + i ae i ) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is 1 MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to6 £ 10 7 Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%.

Revista Mexicana de Física•Jan 1, 2007•2 citations

Laser cooling and trapping of Cs-133 neutral atoms at CENAM

M. Talavera-Ortega, J. M. López Romero, E. de Carlos López

At the moment the National Center of Metrology (CENAM) develops to the necessary technology for the creation of a frequency standard of high accuracy denominated CsF1 atomic fountain. The first stage of development of this clock consists of laser cooling and trapping neutral Cs-133 atoms. The mechanism of laser cooling and trapping of atoms requires of the accomplishment of a magneto-optical trap (MOT) in where is indispensable to maintain a strict control in its parameters of operation. In this experiment, the MOT operates with three set of red detuning |62s1/2, F=4|-> |62s3/2, F'=5| cyclical transition of Cs-133, mutually orthogonal, counterpropagating laser beams, with opposite circular polarization, intersecting at the center of a magnetic field which is generated by a pair of coil in anti-Helmholtz configuration. Additionally, a beam of light that comes from a repumping laser, tuned to the frequency of the |62s1/2, F=3|->|62s3/2, F'=4| transition of Cs-133, is injected to the MOT to maintain an atoms population in the |62s1/2, F=4| state. To cool and trap atoms to so low temperatures, of the order of the microkelvins on the zero absolute, by several seconds, minutes or even by several hours, provided the fundamentals tools to us to study the temporal and spatial behavior of the fluorescence of the atomic cloud and to make exact measurements in the count of such, in order to deduce the parameters of operation of the MOT that allows us to trap 1010 atoms or more. In this work the theoretical concepts as well as the experimental details of the parameters of operation of the MOT for the formation of the cold atom cloud are approached.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 13, 2006•0 citations

Cesium-133 magneto-optical trap at CENAM

J.M. Romero-Lopez, I. Lopez-Dominguez, E.L. De Carlos +1 more

With the aim of developing a cold cesium atom primary frequency standard, a cesium-133 magneto-optical trap (MOT) has been developed at CENAM's Time and Frequency Division. In this paper we present and discuss the main components of the MOT: the optical, vacuum, and mechanical systems.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•2 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R.J. Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Jan 1, 1998•1 citation

Characterization of cold atomic cloud in a magneto-optical trap

Poonam Arora, Swatilekha Chowdhury, Ashish Agarwal +2 more

The results of characterization of cold cloud of cesium (Cs) atoms trapped in a magneto-optical trap (MOT) have been \npresented. The MOT is a part of the Physics package of the Cs Fountain Clock being developed at National Physical \nLaboratory (NPL), India. The number of atoms, size and temperature of the cloud have been measured and calculated. It is also been investigated how the number of trapped atoms changes with the trapping laser’s beam intensity, detuning and magnetic-field gradient of the trap. \n

•Sep 1, 2011•0 citations

Progress on the construction of an atomic cesium fountain at NIM

Tianchu Li, Mingshou Li, Huang Bingying +2 more

An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•1 citation
A primary frequency standard based on cold Cs atoms is under development at the Time and Frequency Division of the Centre Nacional de Metrologia, CENAM. A Cs magneto-optical trap has been developed using the standard sigma+sigma$4-horizontal 2-vertical laser beams of 1.9 cm in diameter, with 5 mW each. We use 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Linewidth of the master laser is 1 MHz. A 50 mW, 852 nm, semiconductor laser is used as slave laser in order to amplify the light of the master laser. The slave laser is stabilized by injection light technique. 12 MHz red shift of the light is performed by double pass through two AOM's. In this paper we present some preliminary results of our MOT characterization as function of MOT's parameters such as intensity of laser beams and gradient of the magnetic field.
A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrolog´ CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration (ae + i ae i ) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is 1 MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to6 £ 10 7 Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%.
At the moment the National Center of Metrology (CENAM) develops to the necessary technology for the creation of a frequency standard of high accuracy denominated CsF1 atomic fountain. The first stage of development of this clock consists of laser cooling and trapping neutral Cs-133 atoms. The mechanism of laser cooling and trapping of atoms requires of the accomplishment of a magneto-optical trap (MOT) in where is indispensable to maintain a strict control in its parameters of operation. In this experiment, the MOT operates with three set of red detuning |62s1/2, F=4|-> |62s3/2, F'=5| cyclical transition of Cs-133, mutually orthogonal, counterpropagating laser beams, with opposite circular polarization, intersecting at the center of a magnetic field which is generated by a pair of coil in anti-Helmholtz configuration. Additionally, a beam of light that comes from a repumping laser, tuned to the frequency of the |62s1/2, F=3|->|62s3/2, F'=4| transition of Cs-133, is injected to the MOT to maintain an atoms population in the |62s1/2, F=4| state. To cool and trap atoms to so low temperatures, of the order of the microkelvins on the zero absolute, by several seconds, minutes or even by several hours, provided the fundamentals tools to us to study the temporal and spatial behavior of the fluorescence of the atomic cloud and to make exact measurements in the count of such, in order to deduce the parameters of operation of the MOT that allows us to trap 1010 atoms or more. In this work the theoretical concepts as well as the experimental details of the parameters of operation of the MOT for the formation of the cold atom cloud are approached.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
The results of characterization of cold cloud of cesium (Cs) atoms trapped in a magneto-optical trap (MOT) have been \npresented. The MOT is a part of the Physics package of the Cs Fountain Clock being developed at National Physical \nLaboratory (NPL), India. The number of atoms, size and temperature of the cloud have been measured and calculated. It is also been investigated how the number of trapped atoms changes with the trapping laser’s beam intensity, detuning and magnetic-field gradient of the trap. \n
An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.