Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Hyperpolarizability effects and accuracy evaluation of a 87Sr optical lattice clock

Rodolphe Le Targat, Anders Brusch, Xavier Baillard, Mathilde Fouché, O. Tcherbakoff, Daniele Rovera, P. Lemonde

Published Jun 1, 2006• 1 citation
Publisher

Abstract

The authors report the observation of the hyperpolarizability frequency shift due to the trapping field in a87Sr optical lattice clock. The authors show that at the magic wavelength of the lattice, where the first order term cancels, this higher order shift will not constitute a limitation to the fractional accuracy of the clock down to the 10-18level. This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm2and by a specific study of the effect of the two two-photon transitions near the magic wavelength. The authors also report an accurate frequency measurement of the clock transition. The frequency is determined to be v1S0-3P0= 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall

DOI
10.1109/freq.2006.275368

Related papers

Hyperpolarizability Effects in a Sr Optical Lattice Clock

Anders Brusch, Rodolphe Le Targat, Xavier Baillard +2 more

We report the observation of a higher-order frequency shift due to the trapping field in a (87)Sr optical lattice clock. We show that, at the magic wavelength of the lattice, where the first-order term cancels, the higher-order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10(-18). This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm(2) and by a specific study of the effect of the two two-photon transitions near the magic wavelength.

arXiv:physics/0512201•Physical Review Letters•Mar 16, 2006•121 citations

Prospects for Optical Clocks with a Blue-Detuned Lattice

Masao Takamoto, Hidetoshi Katori, S. I. Marmo +2 more

We investigated the properties of optical lattice clocks operated with a repulsive light-shift potential. The magic wavelength, where light-shift perturbation for the clock transition cancels, was experimentally determined to be 389.889(9) nm for 87Sr. The hyperpolarizability effects on the clock transition were investigated theoretically. With minimal trapping field perturbation provided by the blue-detuned lattice, the fractional uncertainty due to the hyperpolarizability effects was found to be 2x10;{-19} in the relevant clock transition.

Physical Review Letters•Feb 10, 2009•81 citations

Optical Lattice Polarization Effects on Hyperpolarizability of Atomic Clock Transitions

А. В. Тайченачев, Valeriy I. Yudin, Vitalii D Ovsiannikov +1 more

The light-induced frequency shift due to hyperpolarizability (i.e., terms of second-order in intensity) is studied for a forbidden optical transition, J = 0 --> J = 0. A simple universal dependence on the field ellipticity is obtained. This result allows minimization of the second-order light shift with respect to the field polarization for optical lattices operating at a magic wavelength (at which the first-order shift vanishes). We show the possibility for the existence of a magic elliptical polarization, for which the second-order frequency shift vanishes. The optimal polarization of the lattice field can be either linear, circular, or magic elliptical. The obtained results could improve the accuracy of lattice-based atomic clocks.

arXiv:physics/0606214•Physical Review Letters•Oct 25, 2006•31 citations

Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock

Roger C. Brown, Nate Phillips, K. Beloy +11 more

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

arXiv:1708.08829•Physical Review Letters•Dec 19, 2017•106 citations

Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap

Hidetoshi Katori, Masao Takamoto, V. G. Pal’chikov +1 more

An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the 5s(2) 1S0-->5s5p 3P0 transition of 87Sr atoms as a "clock transition." Calculations of ac multipole polarizabilities and dipole hyperpolarizabilities for the clock transition indicate that the contribution of the higher-order light shifts can be reduced to less than 1 mHz, allowing for a projected accuracy of better than 10(-17).

arXiv:physics/0309043•Physical Review Letters•Oct 24, 2003•580 citations

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•28 citations
The authors report the observation of the hyperpolarizability frequency shift due to the trapping field in a87Sr optical lattice clock. The authors show that at the magic wavelength of the lattice, where the first order term cancels, this higher order shift will not constitute a limitation to the fractional accuracy of the clock down to the 10-18level. This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm2and by a specific study of the effect of the two two-photon transitions near the magic wavelength. The authors also report an accurate frequency measurement of the clock transition. The frequency is determined to be v1S0-3P0= 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall
We report the observation of a higher-order frequency shift due to the trapping field in a (87)Sr optical lattice clock. We show that, at the magic wavelength of the lattice, where the first-order term cancels, the higher-order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10(-18). This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm(2) and by a specific study of the effect of the two two-photon transitions near the magic wavelength.
We investigated the properties of optical lattice clocks operated with a repulsive light-shift potential. The magic wavelength, where light-shift perturbation for the clock transition cancels, was experimentally determined to be 389.889(9) nm for 87Sr. The hyperpolarizability effects on the clock transition were investigated theoretically. With minimal trapping field perturbation provided by the blue-detuned lattice, the fractional uncertainty due to the hyperpolarizability effects was found to be 2x10;{-19} in the relevant clock transition.
The light-induced frequency shift due to hyperpolarizability (i.e., terms of second-order in intensity) is studied for a forbidden optical transition, J = 0 --> J = 0. A simple universal dependence on the field ellipticity is obtained. This result allows minimization of the second-order light shift with respect to the field polarization for optical lattices operating at a magic wavelength (at which the first-order shift vanishes). We show the possibility for the existence of a magic elliptical polarization, for which the second-order frequency shift vanishes. The optimal polarization of the lattice field can be either linear, circular, or magic elliptical. The obtained results could improve the accuracy of lattice-based atomic clocks.
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.
An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the 5s(2) 1S0-->5s5p 3P0 transition of 87Sr atoms as a "clock transition." Calculations of ac multipole polarizabilities and dipole hyperpolarizabilities for the clock transition indicate that the contribution of the higher-order light shifts can be reduced to less than 1 mHz, allowing for a projected accuracy of better than 10(-17).
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.