Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Superconductor Science and Technology

Measurement of the spatial sensitivity of miniature SQUIDs using magnetic-tipped STM

Patrick Josephs-Franks, L Hao, Alexander Ya. Tzalenchuk, Julia A. Davies, Olga Kazakova, John C. Gallop, L. Brown, J.C. Macfarlane

Published Nov 13, 2003• 23 citations
Publisher

Abstract

Large area superconducting quantum interference devices (SQUIDs) are known to be ultimate sensors of magnetic flux. By diminishing the size of a SQUID loop, the energy sensitivity of the device can be increased to near quantum-limited operation whilst also making it less sensitive to external magnetic field noise and improving its coupling to any nano-scale magnetic particle within the loop. This makes it an ideal nano-sensor for magnetic particles including single molecules. It is, however, important to optimize the coupling between any magnetic nano-particle placed within the SQUID and the SQUID itself in order to achieve maximum sensitivity for the spin detection. We have made some preliminary calculations of the expected SQUID response to a magnetic particle placed at different locations within the SQUID device, and using a magnetic tip in a scanning tunnelling microscope (STM) we are able to produce a spatial map of the SQUID sensitivity. Initial results on a 3 µm diameter loop SQUID are presented to demonstrate this method.

DOI
10.1088/0953-2048/16/12/054

Related papers

Performance of nano superconducting quantum interference devices for small spin cluster detection

C. Granata, Antonio Vettoliere, Pravin S. Walke +2 more

In the present paper, performance of nano-superconducting-quantum-interference devices (SQUIDs) has been investigated in view of their employment in the detection of small spin populations. The analysis has been focused on nano-SQUID sensors having a square loop with a side length of 200 nm. We calculate the spin sensitivity and the magnetic response relative to the single Bohr magneton (single spin), as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position; the ratio between the spin sensitivity evaluated in the center of the loop and the minimum one is as high as a factor of 3 for a spin at a reasonable distance z′ of 10 nm from the SQUID plane. Furthermore, the magnetic flux due to several hundred of spins has been evaluated by considering different random spin distributions within the SQUID hole. Due to the both nonuniform SQUID response and the random distribution process, the results show a statistical uncertainty which has been evaluated as a function of the spin number. The estimated informations are very useful to optimize the sensor performance in view of the most nanomagnetism applications.

Journal of Applied Physics•Jul 15, 2009•26 citations

NANO-SQUIDs based on niobium Dayem bridges for nanoscale applications

C. Granata, Antonio Vettoliere, Pravin S. Walke +5 more

We report on the design, the fabrication and the performance of an integrated magnetic nano-sensor based on niobium dc-SQUID (Superconducting QUantum Interference Device) for nanoscale applications is presented. The nano-sensors are based on nanometric niobium constrictions (Dayem bridges) inserted in a square loop having a side length of 200 nm. Measurements of voltage-flux characteristic, flux to voltage transfer factor and noise performances are reported. In small signal mode, the sensors have shown a magnetic flux noise spectral density of 1.5 μΦ 0 /Hz 1/2 corresponding to a spin sensitivity in unit of Bohr magneton of 60 spin/Hz 1/2 . Supercurrent decay measurements of these devices are also reported. Such measurements provide useful information for applications which employ the SQUID as a trigger where the sensor works on the zero voltage state. The experimental data, have shown an intrinsic current fluctuation less than 0.2% of the critical current at liquid helium temperature, corresponding to an intrinsic sensor magnetic flux resolution of a few mΦ 0 . In view of the nano-SQUID employments in the detection of small spin populations, the authors calculated the spin sensitivity and the magnetic response relative to the single spin, as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position.

Journal of Physics Conference Series•Jun 1, 2010•5 citations

Magnetic imaging of superconducting qubit devices with scanning SQUID-on-tip

Estefani Marchiori, L. Ceccarelli, N. Rossi +6 more

We use a scanning superconducting quantum interference device (SQUID) to image the magnetic flux produced by a superconducting device designed for quantum computing. The nanometer-scale SQUID-on-tip probe reveals the flow of superconducting current through the circuit as well as the locations of trapped magnetic flux. In particular, maps of current flowing out of a flux-control line in the vicinity of a qubit show how these elements are coupled, providing insight on how to optimize qubit control.

arXiv:2206.08163•Applied Physics Letters•Aug 1, 2022•27 citations

An integrated superconductive magnetic nanosensor for high-sensitivity nanoscale applications

C. Granata, E. Esposito, Antonio Vettoliere +2 more

An integrated magnetic nanosensor based on a niobium dc SQUID (superconducting quantum interference device) for nanoscale applications is presented. The sensor, having a washer shape with a hole of 200 nm and two Josephson-Dayem nanobridges of 80 nm × 100 nm, consists of a Nb(30 nm)/Al(30 nm) bilayer patterned by electron beam lithography (EBL) and shaped by lift-off and reactive ion etch (RIE) processes. The presence of the niobium coils, integrated on-chip and tightly coupled to the SQUID, allows us to easily excite the sensor in order to get the voltage-flux characteristics and to flux bias the SQUID at its optimal point. The measurements were performed at liquid helium temperature. A voltage swing of 75 µV and a maximum voltage-flux transfer coefficient (responsivity) as high as 1 mV/Φ(0) were directly measured from the voltage-flux characteristic. The noise measurements were performed in open loop mode, biasing the SQUID with a dc magnetic flux at its maximum responsivity point and using direct-coupled low-noise readout electronics. A white magnetic flux noise spectral density as low as 2.5 μΦ(0) Hz(-1/2) was achieved, corresponding to a magnetization or spin sensitivity in units of the Bohr magneton of 100 spin Hz(-1/2). Possible applications of this nanosensor can be envisaged in magnetic detection of nanoparticles and small clusters of atoms and molecules, in the measurement of nanoobject magnetization, and in quantum computing.

Nanotechnology•May 27, 2008•82 citations

Superconducting quantum interference devices with submicron Nb/HfTi/Nb junctions for investigation of small magnetic particles

J. Nagel, O. F. Kieler, T. Weimann +6 more

We investigated, at temperature 4.2 K, electric transport, flux noise, and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a flux noise SΦ1/2=250nΦ0/Hz1/2, corresponding to a spin sensitivity Sμ1/2≥29μB/Hz1/2. For the gradiometer we find SΦ1/2=300nΦ0/Hz1/2 and Sμ1/2≥44μB/Hz1/2. The devices can still be optimized with respect to flux noise and coupling between a magnetic particle and the SQUID, leaving room for further improvement towards single spin resolution.

arXiv:1106.1985•Applied Physics Letters•Jul 18, 2011•62 citations

A terraced scanning super conducting quantum interference device susceptometer with submicron pickup loops

Nicholas C. Koshnick, M. E. Huber, Julie A. Bert +4 more

Superconducting quantum interference devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pickup loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with terraced tips that position the pickup loops 300nm from the sample. The 600nm–2μm pickup loops, defined by focused ion beam, are integrated into a 12-layer optical lithography process allowing flux-locked feedback, in situ background subtraction and optimized flux noise. These features enable a sensitivity of ∼70 electron spins per root hertz at 4K.

arXiv:0901.0308•Applied Physics Letters•Dec 15, 2008•66 citations
Large area superconducting quantum interference devices (SQUIDs) are known to be ultimate sensors of magnetic flux. By diminishing the size of a SQUID loop, the energy sensitivity of the device can be increased to near quantum-limited operation whilst also making it less sensitive to external magnetic field noise and improving its coupling to any nano-scale magnetic particle within the loop. This makes it an ideal nano-sensor for magnetic particles including single molecules. It is, however, important to optimize the coupling between any magnetic nano-particle placed within the SQUID and the SQUID itself in order to achieve maximum sensitivity for the spin detection. We have made some preliminary calculations of the expected SQUID response to a magnetic particle placed at different locations within the SQUID device, and using a magnetic tip in a scanning tunnelling microscope (STM) we are able to produce a spatial map of the SQUID sensitivity. Initial results on a 3 µm diameter loop SQUID are presented to demonstrate this method.
In the present paper, performance of nano-superconducting-quantum-interference devices (SQUIDs) has been investigated in view of their employment in the detection of small spin populations. The analysis has been focused on nano-SQUID sensors having a square loop with a side length of 200 nm. We calculate the spin sensitivity and the magnetic response relative to the single Bohr magneton (single spin), as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position; the ratio between the spin sensitivity evaluated in the center of the loop and the minimum one is as high as a factor of 3 for a spin at a reasonable distance z′ of 10 nm from the SQUID plane. Furthermore, the magnetic flux due to several hundred of spins has been evaluated by considering different random spin distributions within the SQUID hole. Due to the both nonuniform SQUID response and the random distribution process, the results show a statistical uncertainty which has been evaluated as a function of the spin number. The estimated informations are very useful to optimize the sensor performance in view of the most nanomagnetism applications.
We report on the design, the fabrication and the performance of an integrated magnetic nano-sensor based on niobium dc-SQUID (Superconducting QUantum Interference Device) for nanoscale applications is presented. The nano-sensors are based on nanometric niobium constrictions (Dayem bridges) inserted in a square loop having a side length of 200 nm. Measurements of voltage-flux characteristic, flux to voltage transfer factor and noise performances are reported. In small signal mode, the sensors have shown a magnetic flux noise spectral density of 1.5 μΦ 0 /Hz 1/2 corresponding to a spin sensitivity in unit of Bohr magneton of 60 spin/Hz 1/2 . Supercurrent decay measurements of these devices are also reported. Such measurements provide useful information for applications which employ the SQUID as a trigger where the sensor works on the zero voltage state. The experimental data, have shown an intrinsic current fluctuation less than 0.2% of the critical current at liquid helium temperature, corresponding to an intrinsic sensor magnetic flux resolution of a few mΦ 0 . In view of the nano-SQUID employments in the detection of small spin populations, the authors calculated the spin sensitivity and the magnetic response relative to the single spin, as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position.
We use a scanning superconducting quantum interference device (SQUID) to image the magnetic flux produced by a superconducting device designed for quantum computing. The nanometer-scale SQUID-on-tip probe reveals the flow of superconducting current through the circuit as well as the locations of trapped magnetic flux. In particular, maps of current flowing out of a flux-control line in the vicinity of a qubit show how these elements are coupled, providing insight on how to optimize qubit control.
An integrated magnetic nanosensor based on a niobium dc SQUID (superconducting quantum interference device) for nanoscale applications is presented. The sensor, having a washer shape with a hole of 200 nm and two Josephson-Dayem nanobridges of 80 nm × 100 nm, consists of a Nb(30 nm)/Al(30 nm) bilayer patterned by electron beam lithography (EBL) and shaped by lift-off and reactive ion etch (RIE) processes. The presence of the niobium coils, integrated on-chip and tightly coupled to the SQUID, allows us to easily excite the sensor in order to get the voltage-flux characteristics and to flux bias the SQUID at its optimal point. The measurements were performed at liquid helium temperature. A voltage swing of 75 µV and a maximum voltage-flux transfer coefficient (responsivity) as high as 1 mV/Φ(0) were directly measured from the voltage-flux characteristic. The noise measurements were performed in open loop mode, biasing the SQUID with a dc magnetic flux at its maximum responsivity point and using direct-coupled low-noise readout electronics. A white magnetic flux noise spectral density as low as 2.5 μΦ(0) Hz(-1/2) was achieved, corresponding to a magnetization or spin sensitivity in units of the Bohr magneton of 100 spin Hz(-1/2). Possible applications of this nanosensor can be envisaged in magnetic detection of nanoparticles and small clusters of atoms and molecules, in the measurement of nanoobject magnetization, and in quantum computing.
We investigated, at temperature 4.2 K, electric transport, flux noise, and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a flux noise SΦ1/2=250nΦ0/Hz1/2, corresponding to a spin sensitivity Sμ1/2≥29μB/Hz1/2. For the gradiometer we find SΦ1/2=300nΦ0/Hz1/2 and Sμ1/2≥44μB/Hz1/2. The devices can still be optimized with respect to flux noise and coupling between a magnetic particle and the SQUID, leaving room for further improvement towards single spin resolution.
Superconducting quantum interference devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pickup loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with terraced tips that position the pickup loops 300nm from the sample. The 600nm–2μm pickup loops, defined by focused ion beam, are integrated into a 12-layer optical lithography process allowing flux-locked feedback, in situ background subtraction and optimized flux noise. These features enable a sensitivity of ∼70 electron spins per root hertz at 4K.