Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser Physics Letters

Experimental investigation of the statistical distribution of single atoms in cavity quantum electrodynamics

Jinjin Du, Wenfang Li, Ruijuan Wen, Gang Li, Tiancai Zhang

Published May 11, 2015• 9 citations
Publisher

Abstract

Abstract The Hanbury Brown–Twiss experiment for a beam of photons or atoms can be performed using counting experiments. We present the statistical distribution of single 133 Cs atoms detected by a high finesse microcavity, which acts as a point-like single-atom counter. The distribution of the arrival times of the atoms and the correlation between the atoms was obtained based on the full counting statistics of the beam emitted from the cavity. The bunching behavior of the thermal atomic beams is clearly observable using this type of atom–cavity system. The correlation between the cesium atoms depends on the temperature of the atom cloud, and the corresponding parameters may be found by fitting an experimentally measured curve using the theory of multimode thermal light.

DOI
10.1088/1612-2011/12/6/065501

Related papers

Correlations and Counting Statistics of an Atom Laser

Anton Öttl, Stephan Ritter, Michael Köhl +1 more

We demonstrate time-resolved counting of single atoms extracted from a weakly interacting Bose-Einstein condensate of 87Rb atoms. The atoms are detected with a high-finesse optical cavity and single atom transits are identified. An atom laser beam is formed by continuously output coupling atoms from the Bose-Einstein condensate. We investigate the full counting statistics of this beam and measure its second order correlation function g((2))(tau) in a Hanbury Brown-Twiss type experiment. For the monoenergetic atom laser we observe a constant correlation function g((2))(tau)=1.00 +/- 0.01 and an atom number distribution close to a Poissonian statistics. A pseudothermal atomic beam shows a bunching behavior and a Bose distributed counting statistics.

arXiv:cond-mat/0508439•Physical Review Letters•Aug 26, 2005•323 citations

Temperature determination of cold atoms based on single-atom countings

Pengfei Zhang, Yanqiang Guo, Zhuoheng Li +6 more

Based on the real sense of the time-of-flight , we demonstrate an alternative method of measuring the temperature of cold atoms in magneto-optical traps (MOTs) using a high-finesse optical microcavity, which acts as a pointlike single-atom counter. A cloud of atoms trapped in magneto-optical traps is positioned about 5 mm above the cavity, and the atoms fall freely down through the cavity. The temperature of the cold atoms in the MOT is determined by counting the exact arrival times of the single atoms. A theoretical model based on a ballistic expansion of a cloud of trapped atoms falling in the earth’s gravitational field is used to fit the probability distribution of atom arrivals, and the fittings agree very well with the experimental results. This method could be used for systems with little room, where an extra probe beam is hard to involve, or with fewer atoms initially.

Journal of the Optical Society of America B•Mar 9, 2011•13 citations

High-order photon correlations through double Hanbury Brown–Twiss measurements

Yanqiang Guo, Lijing Wang, Yu Wang +4 more

Abstract We present an experimental technique that can accurately measure the high-order photon correlations of various light fields based on double Hanbury Brown–Twiss scheme. The system consists of four conventional binary response single-photon counting modules which are non-photon-number-resolving detectors. We theoretically analyze the effects of the experimental conditions on the high-order photon correlations of coherent, chaotic thermal, Fock and squeezed vacuum states with considering the overall efficiency and background noise. In experiment, we determine the proper resolution time from 2 9 = 512 ns to 2 11 = 2048 ns and counting rate from 10 kc s −1 to 100 kc s −1 for characterizing the exact second-, third- and fourth-order photon correlations of chaotic thermal state. At complete time delays, we also observe the third- and fourth-order photon correlations of chaotic thermal state, with the maximum high-order correlation values of 5.99 ± 0.02 and 23.9 ± 0.2 respectively, which are in good agreement with the theoretical values of 6 and 24. The demonstrated experimental technique with high accuracy is a promising tool for investigating quantum optical coherence and ghost imaging.

Journal of Optics•Jul 7, 2020•10 citations

Hanbury Brown–Twiss Correlations to Probe the Population Statistics of GHz Photons Emitted by Conductors

Julien Gabelli, Laure-Hélène Reydellet, Gwendal Fève +4 more

We present the first study of the statistics of GHz photons in quantum circuits, using Hanbury Brown and Twiss correlations. The super-Poissonian and Poissonian photon statistics of thermal and coherent sources, respectively, made of a resistor and a radio frequency generator, are measured down to the quantum regime at milli-Kelvin temperatures. As photon correlations are linked to the second and fourth moments of current fluctuations, this experiment, which is based on current cryogenic electronics, may become a standard for probing electron/photon statistics in quantum conductors.

arXiv:cond-mat/0403584•Physical Review Letters•Jul 27, 2004•60 citations

Experiments in Cavity QED: Exploring the Interaction of Quantized Light with a Single Trapped Atom

Andreea Boca

The experiments discussed in this thesis focus on the interaction of a single trapped atom with the single mode of a high-finesse optical cavity, in the regime of strong coupling. Chapter 1 gives a brief introduction, after which Chapter 2 describes our recent measurements of the transmission spectrum of the atom-cavity system. The spectrum exhibits a clearly resolved vacuum-Rabi splitting, in good quantitative agreement with theoretical predictions. A new Raman scheme for cooling atomic motion along the cavity axis enables a complete spectrum to be recorded for an individual atom trapped within the cavity mode, in contrast to all previous measurements of this type that have required averaging over 10^3-10^5 atoms. Chapter 3 discusses our observations of photon blockade for the transmitted light in the presence of one trapped atom. Excitation of the atom-cavity system by a first photon blocks the transmission of a second one, thereby converting an incident Poissonian stream of photons into a sub-Poissonian, anti-bunched stream, as confirmed by measurements of the photon statistics of the transmitted field. The intensity correlations of the cavity transmission also reveal the energy distribution for oscillatory motion of the trapped atom. Chapter 4 details a set of simple but necessary measurements of relevant experimental parameters such as cavity geometry, linewidth, mirror properties, birefringence, and detection efficiency. The thesis concludes with Appendix A, describing the efficient laser setup we use for our magneto-optical traps.

•May 31, 2005•3 citations

Hanbury Brown Twiss Effect for Ultracold Quantum Gases

M. Schellekens, Rodolphe Hoppeler, A. Perrin +4 more

We have studied two-body correlations of atoms in an expanding cloud above and below the Bose-Einstein condensation threshold. The observed correlation function for a thermal cloud shows a bunching behavior, whereas the correlation is flat for a coherent sample. These quantum correlations are the atomic analog of the Hanbury Brown Twiss effect. We observed the effect in three dimensions and studied its dependence on cloud size.

arXiv:cond-mat/0508466•Science•Sep 15, 2005•348 citations
Abstract The Hanbury Brown–Twiss experiment for a beam of photons or atoms can be performed using counting experiments. We present the statistical distribution of single 133 Cs atoms detected by a high finesse microcavity, which acts as a point-like single-atom counter. The distribution of the arrival times of the atoms and the correlation between the atoms was obtained based on the full counting statistics of the beam emitted from the cavity. The bunching behavior of the thermal atomic beams is clearly observable using this type of atom–cavity system. The correlation between the cesium atoms depends on the temperature of the atom cloud, and the corresponding parameters may be found by fitting an experimentally measured curve using the theory of multimode thermal light.
We demonstrate time-resolved counting of single atoms extracted from a weakly interacting Bose-Einstein condensate of 87Rb atoms. The atoms are detected with a high-finesse optical cavity and single atom transits are identified. An atom laser beam is formed by continuously output coupling atoms from the Bose-Einstein condensate. We investigate the full counting statistics of this beam and measure its second order correlation function g((2))(tau) in a Hanbury Brown-Twiss type experiment. For the monoenergetic atom laser we observe a constant correlation function g((2))(tau)=1.00 +/- 0.01 and an atom number distribution close to a Poissonian statistics. A pseudothermal atomic beam shows a bunching behavior and a Bose distributed counting statistics.
Based on the real sense of the time-of-flight , we demonstrate an alternative method of measuring the temperature of cold atoms in magneto-optical traps (MOTs) using a high-finesse optical microcavity, which acts as a pointlike single-atom counter. A cloud of atoms trapped in magneto-optical traps is positioned about 5 mm above the cavity, and the atoms fall freely down through the cavity. The temperature of the cold atoms in the MOT is determined by counting the exact arrival times of the single atoms. A theoretical model based on a ballistic expansion of a cloud of trapped atoms falling in the earth’s gravitational field is used to fit the probability distribution of atom arrivals, and the fittings agree very well with the experimental results. This method could be used for systems with little room, where an extra probe beam is hard to involve, or with fewer atoms initially.
Abstract We present an experimental technique that can accurately measure the high-order photon correlations of various light fields based on double Hanbury Brown–Twiss scheme. The system consists of four conventional binary response single-photon counting modules which are non-photon-number-resolving detectors. We theoretically analyze the effects of the experimental conditions on the high-order photon correlations of coherent, chaotic thermal, Fock and squeezed vacuum states with considering the overall efficiency and background noise. In experiment, we determine the proper resolution time from 2 9 = 512 ns to 2 11 = 2048 ns and counting rate from 10 kc s −1 to 100 kc s −1 for characterizing the exact second-, third- and fourth-order photon correlations of chaotic thermal state. At complete time delays, we also observe the third- and fourth-order photon correlations of chaotic thermal state, with the maximum high-order correlation values of 5.99 ± 0.02 and 23.9 ± 0.2 respectively, which are in good agreement with the theoretical values of 6 and 24. The demonstrated experimental technique with high accuracy is a promising tool for investigating quantum optical coherence and ghost imaging.
We present the first study of the statistics of GHz photons in quantum circuits, using Hanbury Brown and Twiss correlations. The super-Poissonian and Poissonian photon statistics of thermal and coherent sources, respectively, made of a resistor and a radio frequency generator, are measured down to the quantum regime at milli-Kelvin temperatures. As photon correlations are linked to the second and fourth moments of current fluctuations, this experiment, which is based on current cryogenic electronics, may become a standard for probing electron/photon statistics in quantum conductors.
The experiments discussed in this thesis focus on the interaction of a single trapped atom with the single mode of a high-finesse optical cavity, in the regime of strong coupling. Chapter 1 gives a brief introduction, after which Chapter 2 describes our recent measurements of the transmission spectrum of the atom-cavity system. The spectrum exhibits a clearly resolved vacuum-Rabi splitting, in good quantitative agreement with theoretical predictions. A new Raman scheme for cooling atomic motion along the cavity axis enables a complete spectrum to be recorded for an individual atom trapped within the cavity mode, in contrast to all previous measurements of this type that have required averaging over 10^3-10^5 atoms. Chapter 3 discusses our observations of photon blockade for the transmitted light in the presence of one trapped atom. Excitation of the atom-cavity system by a first photon blocks the transmission of a second one, thereby converting an incident Poissonian stream of photons into a sub-Poissonian, anti-bunched stream, as confirmed by measurements of the photon statistics of the transmitted field. The intensity correlations of the cavity transmission also reveal the energy distribution for oscillatory motion of the trapped atom. Chapter 4 details a set of simple but necessary measurements of relevant experimental parameters such as cavity geometry, linewidth, mirror properties, birefringence, and detection efficiency. The thesis concludes with Appendix A, describing the efficient laser setup we use for our magneto-optical traps.