Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Classical noise and flux: The limits of multi-state atom lasers

J. D. Close, Nicholas P. Robins, Craig M. Savage, J. J. Hope, Jessica Lye, Cameron S. Fletcher, Simon A. Haine

Published Jan 1, 2004• 1 citation
Publisher

Abstract

By comparison between experiment and theory, we show how the classical noise on a multi-state atom laser beam increases with increasing flux. Such considerations will be important in future precision measurement techniques utilising atom lasers.
DOI
10.1364/iqec.2004.ima4

Related papers

Fluctuations and flux: The limits of multistate atom lasers

Nicholas P. Robins, Craig M. Savage, J. J. Hope +4 more

By direct comparison between experiment and theory with no adjustable parameters, we show how the classical fluctuations on a multistate atom laser beam increase with increasing flux. The fluctuations are inherent to state changing out coupling, rf, Raman, or otherwise and are likely to be present in all atom lasers, pulsed or continuous, that employ such out coupling. If not removed or avoided, these classical fluctuations will prevent shot noise limited measurement employing atom lasers of this kind.

arXiv:cond-mat/0311361•Physical Review A•May 19, 2004•30 citations

High flux atom lasers, interferometry, and the shot noise limit

Nicholas P. Robins, J. J. Hope, Simon A. Haine +5 more

In this paper we present experimental results on flux, fluctuations and noise on an atom laser beam and discuss the implications of these measurements to high precision interferometry with atoms.

Conference on Lasers and Electro-Optics•Jan 1, 2006•0 citations

Spectroscopy squeezed beyond the shot-noise limit

Philippe Grangier

For many years the "shot-noise limit" has been considered as the fundamental limitation on measurements made with light beams. Shot noise is due to the quantum nature of light: the number of photons detected in a given time from a "stable" light beam (for instance, a laser beam) is an intrinsically random number which has fluctuations of order N1/2 if the average result is N. So if the number of photons, N, is limited by time or power considerations, shot noise places a fundamental limitation on the precision to which intensity, and changes in intensity, can be measured. This is particularly critical for "one-shot" ultra-sensitive experiments, such as the detection of a gravitational burst using large-scale interferometers.

Physics World•Aug 1, 1992•1 citation

Flux Limitations of Continuous Atom Lasers

Adele K. Morrison

If atom lasers are to transform many fields of physics, as well as find applications in industry, the most essential development needed is increased atom flux. In this thesis we report on the experimental observation of fundamental limits on the flux of continuous atom lasers. The flux produced by the commonly used radio frequency outcoupler, can not be arbitrarily increased by increasing the strength of the outcoupling. Above a critical Rabi frequency, the atom laser shows large classical density fluctuations, due to coupling between the multiple Zeeman states. In our system this critical Rabi frequency is about 1 kHz. Futhermore, at large coupling strengths (> 4 kHz for our experimetnal parameters), the continuous atom laser output completely switches off, as a result of the atoms remaining trapped in a bound state. In addition to the investigations of the radio frequency outcoupler, we have demonstrated the first continuous Raman outcoupled atom laser. Preliminary data indicates that the Raman outcoupler will be flux limited in a similar way to the radio frequency outcoupler.

•Jan 1, 2005•0 citations

Atom-laser dynamics

Nicholas P. Robins, Craig M. Savage, Elena A. Ostrovskaya

An ideal atom laser would produce an atomic beam with highly stable flux and energy. In practice, the stability is likely to be limited by technical noise and nonlinear dynamical effects. We investigate the dynamics of an atom laser using a comprehensive one-dimensional, mean-field numerical model. We fully model the output beam and experimentally important physics such as three-body recombination. We find that at high-pump rates, the latter plays a role in suppressing the high-frequency dynamics, which would otherwise limit the stability of the output beam.

arXiv:cond-mat/0103597•Physical Review A•Sep 13, 2001•22 citations

Density shift measurement and synchronous frequency comparison based on in situ imaging technique

Xiaohua Hu, Xiaotong Lu, Xiao-Fei Zhang +1 more

Precision measurement of the density shift caused by the interaction among neutral atoms trapped in an optical lattice has important applications in the study of multi-body interaction and the realization of high-performance optical lattice clocks. The common methods of measuring the density are the self-comparison technique and frequency comparison between two optical lattice clocks. Both methods are based on the identical density shift coefficient and should interrelatedly operate the clock at high- and low-density state, respectively. The precision of self-comparison method is limited by the Dick effect. The synchronous frequency comparison between two optical lattice clocks can realize the precision beyond the Dick limit. However, both methods can only obtain the average density shift and ignore the fact that the magnitude of the density shift is different over the lattice sites as inhomogeneous density distribution in the lattice. In this paper, the synchronous frequency comparison technique based on in situ imaging is used to accurately measure the density shift coefficient of optical lattice clock. Atoms in the optical lattice are simultaneously and independently excited by the same clock laser beam, and the clock transition probability of 11 uncorrelated regions of the optical lattice is simultaneously detected by in situ imaging. Thus, the clock laser noise, which is the root cause of the Dick effect, is common-mode rejected as the frequency difference between uncorrelated regions is measured by the clock transition spectrum. Beyond the Dick-noise-limited stability, the stability of synchronous frequency comparison between uncorrelated regions is consistent with the limit resulting from the atom detection noise. Between the center and margin of the lattice, the differential shifts of the black-body radiation shift, lattice AC Stark shift, probe Stark shift, DC Stark shift, and quadratic Zeeman shift are all below 5 × 10–6 Hz, which is three orders of magnitude smaller than the density shift and can be ignored in this experiment. Benefitting from the inhomogeneous distribution of atom number and negligible external field gradient in the optical lattice, the compared frequency shift between uncorrelated regions indicates the density shift. By measuring the relationship between the density shift and atom difference, the density shift coefficient is determined as –0.101(3) Hz/atom/site (with a measurement time of 103 s), and the fractional measurement uncertainty of the mean density shift of our system is 1.5 × 10–17.

Acta Physica Sinica•Jan 1, 2022•0 citations
By direct comparison between experiment and theory with no adjustable parameters, we show how the classical fluctuations on a multistate atom laser beam increase with increasing flux. The fluctuations are inherent to state changing out coupling, rf, Raman, or otherwise and are likely to be present in all atom lasers, pulsed or continuous, that employ such out coupling. If not removed or avoided, these classical fluctuations will prevent shot noise limited measurement employing atom lasers of this kind.
For many years the "shot-noise limit" has been considered as the fundamental limitation on measurements made with light beams. Shot noise is due to the quantum nature of light: the number of photons detected in a given time from a "stable" light beam (for instance, a laser beam) is an intrinsically random number which has fluctuations of order N1/2 if the average result is N. So if the number of photons, N, is limited by time or power considerations, shot noise places a fundamental limitation on the precision to which intensity, and changes in intensity, can be measured. This is particularly critical for "one-shot" ultra-sensitive experiments, such as the detection of a gravitational burst using large-scale interferometers.
If atom lasers are to transform many fields of physics, as well as find applications in industry, the most essential development needed is increased atom flux. In this thesis we report on the experimental observation of fundamental limits on the flux of continuous atom lasers. The flux produced by the commonly used radio frequency outcoupler, can not be arbitrarily increased by increasing the strength of the outcoupling. Above a critical Rabi frequency, the atom laser shows large classical density fluctuations, due to coupling between the multiple Zeeman states. In our system this critical Rabi frequency is about 1 kHz. Futhermore, at large coupling strengths (> 4 kHz for our experimetnal parameters), the continuous atom laser output completely switches off, as a result of the atoms remaining trapped in a bound state. In addition to the investigations of the radio frequency outcoupler, we have demonstrated the first continuous Raman outcoupled atom laser. Preliminary data indicates that the Raman outcoupler will be flux limited in a similar way to the radio frequency outcoupler.
An ideal atom laser would produce an atomic beam with highly stable flux and energy. In practice, the stability is likely to be limited by technical noise and nonlinear dynamical effects. We investigate the dynamics of an atom laser using a comprehensive one-dimensional, mean-field numerical model. We fully model the output beam and experimentally important physics such as three-body recombination. We find that at high-pump rates, the latter plays a role in suppressing the high-frequency dynamics, which would otherwise limit the stability of the output beam.
Precision measurement of the density shift caused by the interaction among neutral atoms trapped in an optical lattice has important applications in the study of multi-body interaction and the realization of high-performance optical lattice clocks. The common methods of measuring the density are the self-comparison technique and frequency comparison between two optical lattice clocks. Both methods are based on the identical density shift coefficient and should interrelatedly operate the clock at high- and low-density state, respectively. The precision of self-comparison method is limited by the Dick effect. The synchronous frequency comparison between two optical lattice clocks can realize the precision beyond the Dick limit. However, both methods can only obtain the average density shift and ignore the fact that the magnitude of the density shift is different over the lattice sites as inhomogeneous density distribution in the lattice. In this paper, the synchronous frequency comparison technique based on in situ imaging is used to accurately measure the density shift coefficient of optical lattice clock. Atoms in the optical lattice are simultaneously and independently excited by the same clock laser beam, and the clock transition probability of 11 uncorrelated regions of the optical lattice is simultaneously detected by in situ imaging. Thus, the clock laser noise, which is the root cause of the Dick effect, is common-mode rejected as the frequency difference between uncorrelated regions is measured by the clock transition spectrum. Beyond the Dick-noise-limited stability, the stability of synchronous frequency comparison between uncorrelated regions is consistent with the limit resulting from the atom detection noise. Between the center and margin of the lattice, the differential shifts of the black-body radiation shift, lattice AC Stark shift, probe Stark shift, DC Stark shift, and quadratic Zeeman shift are all below 5 × 10–6 Hz, which is three orders of magnitude smaller than the density shift and can be ignored in this experiment. Benefitting from the inhomogeneous distribution of atom number and negligible external field gradient in the optical lattice, the compared frequency shift between uncorrelated regions indicates the density shift. By measuring the relationship between the density shift and atom difference, the density shift coefficient is determined as –0.101(3) Hz/atom/site (with a measurement time of 103 s), and the fractional measurement uncertainty of the mean density shift of our system is 1.5 × 10–17.