We address the estimation of purity for a quantum oscillator initially prepared in a displaced thermal state and probed by a suitably prepared qubit interacting with the oscillator via Jaynes–Cummings Hamiltonian without the rotating-wave approximation. We evaluate the quantum Fisher information (QFI) and show that optimal estimation of purity can be achieved by measuring the population of the qubit after a properly chosen interaction time. We also address the estimation of purity at fixed total energy and show that the corresponding precision is independent of the presence of a coherent amplitude.
We address the estimation of purity for a quantum oscillator initially prepared in a displaced thermal state and probed by a suitably prepared qubit interacting with the oscillator via Jaynes–Cummings Hamiltonian without the rotating-wave approximation. We evaluate the quantum Fisher information (QFI) and show that optimal estimation of purity can be achieved by measuring the population of the qubit after a properly chosen interaction time. We also address the estimation of purity at fixed total energy and show that the corresponding precision is independent of the presence of a coherent amplitude.
We address estimation of temperature for a micromechanical oscillator lying arbitrarily close to its quantum ground state. Motivated by recent experiments, we assume that the oscillator is coupled to a probe qubit via Jaynes-Cummings interaction and that the estimation of its effective temperature is achieved via quantum-limited measurements on the qubit. We first consider the ideal unitary evolution in a noiseless environment and then take into account the noise due to nondissipative decoherence. We exploit local quantum estimation theory to assess and optimize the precision of estimation procedures based on the measurement of qubit population and to compare their performances with the ultimate limit posed by quantum mechanics. In particular, we evaluate the Fisher information (FI) for population measurement, maximize its value over the possible qubit preparations and interaction times, and compare its behavior with that of the quantum Fisher information (QFI). We found that the FI for population measurement is equal to the QFI, i.e., population measurement is optimal, for a suitable initial preparation of the qubit and a predictable interaction time. The same configuration also corresponds to the maximum of the QFI itself. Our results indicate that the achievement of the ultimate bound to precision allowed by quantum mechanics is in the capabilities of the current technology.
Quantum probing consists of suitably exploiting a simple, small, and controllable quantum system to characterize a larger and more complex system. Here, we address the estimation of the cutoff frequency of the Ohmic spectral density of a harmonic reservoir by quantum probes. To this aim, we address the use of single-qubit and two-qubit systems and different kinds of coupling with the bath of oscillators. We assess the estimation precision by the quantum Fisher information of the sole quantum probe as well as the corresponding quantum signal-to-noise ratio. We prove that, for most of the values of the Ohmicity parameter, a simple probe such as a single qubit is already optimal for the precise estimation of the cutoff frequency. Indeed for those values, upon considering a two-qubit probe either in a Bell or in separable state, we do not find improvement to the estimation precision. However, we also showed that there exist few conditions where employing two qubits in a Bell state interacting with a common bath is more suitable for precisely estimating the cutoff frequency.
From a qubit in a noisy state affected by an uncontrolled decohering environment represented by a thermal bath at temperature T , estimation of the norm of its Bloch vector is considered, equivalent to estimation of its purity or of its linear entropy. The performance in estimation is assessed by the quantum Fisher information. When the qubit can be prepared with an optimal orientation precisely matched to the thermal noise, the estimation performance always degrades with an increasing temperature of the bath. On the contrary, for a non‐optimal orientation of the qubit, the possibility of an enhancement of the estimation performance with an increasing temperature of the bath is demonstrated. Such behaviour shows that increased decoherence is not necessarily associated with poorer informational performance, and can be compared with stochastic resonance or useful noise effects previously reported in classical (non‐quantum) estimation.
Quantum Fisher information sets the ultimate precision of quantum parameter estimation, yet measuring it generally requires full state tomography or an explicit reconstruction of the symmetric logarithmic derivative. We show that, in the short-time limit, it is fixed by a single variance, that of the operator generating the parameter shift, evaluated in the initial state. For two pure states evolving under the same Hamiltonian, the ratio of their quantum Fisher information equals the ratio of these variances, so the value for an unknown state follows from a characterized reference. When every initial state is a cavity state tensored with the atomic ground state, this ratio reduces to that of the short-time changes in the atomic energy, and projective measurements of the Pauli spin operator on the atom alone suffice. We apply the relation to the extended multiphoton Rabi and Jaynes–Cummings models. The numerics confirm the predicted agreement, quantify the finite-time deviations that bound the useful measurement window, and show how the reference state, through its mean photon number and statistical family, governs how long this agreement persists. The scheme needs no state reconstruction and no measurement optimization, and we quantify both the finite-time bias and the statistical resources required.
The precise determination of a displacement of a mechanical oscillator or a microwave field in a predetermined direction in phase space can be carried out with trapped ions or superconducting circuits, respectively, by coupling the oscillator with ancilla qubits. Through that coupling, the displacement information is transferred to the qubits which are then subsequently read out. However, unambiguous estimation of displacement in an unknown direction in the phase space has not been attempted in such oscillator-qubit systems. Here, we propose a hybrid oscillator-qubit interferometric setup for the unambiguous estimation of phase space displacements in an arbitrary direction, based on feasible Rabi interactions beyond the rotating-wave approximation. Using such a hybrid Rabi interferometer for quantum sensing, we show that the performance is superior to the ones attained by single-mode estimation schemes and a conventional interferometer based on Jaynes-Cummings interactions. Moreover, we find that the sensitivity of the Rabi interferometer is independent of the thermal occupation of the oscillator mode, and thus cooling it to the ground state before sensing is not required. We also perform a thorough investigation of the effect of qubit dephasing and oscillator thermalization. We find the interferometer to be fairly robust, outperforming different benchmark estimation schemes even for large dephasing and thermalization.
We study in this work the metrology precision of a probe system coupled to an ancillary qubit. Restricting the probe-qubit coupling along only one or two directions is found to be a sufficient criterion for the effective dynamical generator to achieve the Heisenberg limit in precision. Under the criterion, the quantum Fisher information (QFI) about the to-be-estimated parameter becomes the expectation value of mean square of the effective generator with respect to the initial state of the composite system. Our criterion is justified in two distinct systems. For a bosonic probe, QFI about the displacement estimation is found to be proportional to the mean excitation number of probe. It renders a counterintuitive result that quantum metrology sensitivity can be enhanced by increasing the temperature of the probe system. For a spin-ensemble probe, QFI about both rotation-phase and magnetic-field estimation exhibit a quadratic dependence on the probe-spin number. It is found that even when the spin-ensemble is prepared as a finite-temperature state, faraway from the so-called resource states, e.g., the squeezed state or the Greenberger-Horne-Zeilinger state, QFI can still manifest a Heisenberg scaling behavior.