Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

One- and two-photon interference from two temporally separated laser pulses

Y.-H. Kim, V. Berardi, Chekhova, Maria, Garuccio, Augusto, Shih, Yanhua

Published May 7, 2000• 0 citations
Publisher

Abstract

According to Feynman, quantum mechanics teaches us that interference occurs when the relevant amplitudes become indistinguishable. In the case of first-order and second-order in terference (order by "intensity"), the relevant amplitudes are one-photon and two-photon amplitudes, respectively.
DOI
10.13016/m2hirs-ymo7

Related papers

One- and two-photon interference from two temporally separated laser pulses

Kim, Berardi, Chekhova +2 more

Quantum Electronics and Laser Science Conference•Jan 1, 2000•0 citations

Quantum interference by two temporally distinguishable pulses

Yoon-Ho Kim, Maria V. Chekhova, S. P. Kulik +1 more

We report a two-photon interference effect, in which the entangled photon pairs are generated from two laser pulses well separated in time. In a single pump pulse case, interference effects did not occur in our experimental scheme. However, by introducing a second pump pulse delayed in time, quantum interference was then observed. The visibility of the interference fringes shows a dependence on the delay time between two laser pulses. The results are explained in terms of indistinguishability of biphoton amplitudes that originates from two temporally separated laser pulses.

arXiv:quant-ph/9903048•Physical Review A•Jul 1, 1999•20 citations

Quantum Interference by Two Temporally Distinguishable Pulses

Yoon-Ho Kim, Maria V. Chekhova, S. P. Kulik +3 more

We report a two-photon interference effect, in which the entangled photon pairs are generated from two laser pulses well-separated in time. In a single pump pulse case, interference effects did not occur in our experimental scheme. However, by introducing a second pump pulse delayed in time, quantum interference was then observed. The visibility of the interference fringes shows a dependence on the delay time between two laser pulses. The results are explained in terms of indistinguishability of biphoton amplitudes which originates from two temporally separated laser pulses.

Fortschritte der Physik•May 1, 2000•0 citations

Interference of single photons

Oleg N Krokhin

The observed interference of single photons is explained without contradiction with the indivisibility principle.

Bulletin of the Lebedev Physics Institute•Apr 1, 2014•0 citations

Two-photon interference with two (and only two) independent photons

Frank King, Margaret Trias, Martin Ligare

Bulletin of the American Physical Society•May 23, 2009•0 citations

Quantum interference by two temporally distinguishable pulses

Y.-H. Kim, Maria V. Chekhova, S. P. Kulik +1 more

We have experimentally demonstrated two-photon interference between biphoton amplitudes arising from two well-separated pump pulses. It is important to note the following. 1) The pump pulse intensity was low enough so that single counting rates of the detectors were kept much smaller than pulse repetition rates: the probability of having one spontaneous parametric down conversion (SPDC) photon pair per pulse in our experiment is negligible. Hence the interference cannot be explained as two SPDC photons from two pump pulses (one SPDC photon pair from each pulse) interfering at the detectors. The two pump pulses simply provide two biphoton amplitudes which could result in coincidence counts, and interference occurs between these two biphoton amplitudes only when they are indistinguishable. 2) The BBO crystal in our experiment was only 100 /spl mu/m thick, so the two-pulse did not exist in BBO at the same time at any moment. 3) Due to the delays in the interferometer (/spl tau/ /spl tau//sub 1/), the signal-idler never met at the beamsplitter. Therefore, the existence of two-photon interference cannot be viewed as the interference between the signal and idler photons. These three points again emphasize the fact that it is the indistinguishability of the two-photon Feynman alternatives for the biphoton amplitudes which is responsible for the two-photon quantum interference effects.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jan 20, 2003•0 citations
We report a two-photon interference effect, in which the entangled photon pairs are generated from two laser pulses well separated in time. In a single pump pulse case, interference effects did not occur in our experimental scheme. However, by introducing a second pump pulse delayed in time, quantum interference was then observed. The visibility of the interference fringes shows a dependence on the delay time between two laser pulses. The results are explained in terms of indistinguishability of biphoton amplitudes that originates from two temporally separated laser pulses.
We report a two-photon interference effect, in which the entangled photon pairs are generated from two laser pulses well-separated in time. In a single pump pulse case, interference effects did not occur in our experimental scheme. However, by introducing a second pump pulse delayed in time, quantum interference was then observed. The visibility of the interference fringes shows a dependence on the delay time between two laser pulses. The results are explained in terms of indistinguishability of biphoton amplitudes which originates from two temporally separated laser pulses.
We have experimentally demonstrated two-photon interference between biphoton amplitudes arising from two well-separated pump pulses. It is important to note the following. 1) The pump pulse intensity was low enough so that single counting rates of the detectors were kept much smaller than pulse repetition rates: the probability of having one spontaneous parametric down conversion (SPDC) photon pair per pulse in our experiment is negligible. Hence the interference cannot be explained as two SPDC photons from two pump pulses (one SPDC photon pair from each pulse) interfering at the detectors. The two pump pulses simply provide two biphoton amplitudes which could result in coincidence counts, and interference occurs between these two biphoton amplitudes only when they are indistinguishable. 2) The BBO crystal in our experiment was only 100 /spl mu/m thick, so the two-pulse did not exist in BBO at the same time at any moment. 3) Due to the delays in the interferometer (/spl tau/ /spl tau//sub 1/), the signal-idler never met at the beamsplitter. Therefore, the existence of two-photon interference cannot be viewed as the interference between the signal and idler photons. These three points again emphasize the fact that it is the indistinguishability of the two-photon Feynman alternatives for the biphoton amplitudes which is responsible for the two-photon quantum interference effects.