Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Journal of Quantum Electronics

Amplitude squeezing from singly resonant frequency-doubling laser

Joji Maeda, T. Numata, S. Kogoshi

Published Jul 1, 1997• 5 citations
Publisher

Abstract

We analyze amplitude squeezing from a singly resonant frequency-doubling laser oscillating at a single frequency. In this laser system, the cavity loss depends on the intensity of the oscillating fundamental field, so that conventional analyses based on a mean-field approximation become invalid in a highly pumped regime. To avoid this inconvenience, we consider spatial evolution of fields both in a laser medium and in a nonlinear crystal. It is predicted for the first time that a combination of excess nonlinearity and modest laser saturation can increase the output noise. We propose novel indices to evaluate the possible noise enhancement and suggest a design rule for squeezed light generation.

DOI
10.1109/3.594866

Related papers

Bright squeezing by singly resonant second-harmonic generation: effect of fundamental depletion and feedback

Joji Maeda, Kazuro Kikuchi

We analyze the squeezing characteristics of a singly resonant second-harmonic-generation system, in which only the fundamental light is confined in a plain cavity resonator, with consideration for fundamental depletion in a nonlinear crystal. The system was analyzed under the mean-field approximation, which neglects the variation of the field in the crystal, and as much as 9.5 dB of squeezing was predicted in the second-harmonic output. On the basis of the self-consistent method, we analyze the system, which is driven by such an intense fundamental input that the mean-field approximation is not valid, and predict that an arbitrary amount of squeezing will be available in this regime.

Optics Letters•Jun 1, 1996•11 citations

Generation of continuous-wave bright-squeezed light

Stephan Schiller, Gerd Breitenbach, Silvania F. Pereira +3 more

We discuss different approaches to the generation of bright amplitude-squeezed light using second-order nonlinear effects in optical cavities. A 0.2 mW beam at 1064 nm exhibiting 4 dB squeezing has been generated using a phase-sensitive type-I parametric amplifier pumped by a frequency-doubled Nd:YAG laser. In applying frequency-doubling processes to the generation of amplitude-squeezed light, the appearance of parasitic parametric oscillation must be considered. This effect has been observed in a singly-resonant frequency doubler. We also describe recent developments in optical cavity design for doubly-resonant frequency-doubling. Finally, we show theoretically that phase-mismatched second-harmonic generation in an optical cavity can be employed to generate a strong effective Kerr nonlinearity. This system appears promising for achieving optical bistability and for generating squeezed light of high power. Keywords: Non-classical light, squeezed light, amplitude squeezing, nonlinear op...

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 26, 1995•6 citations

Generation of squeezed states of light by intracavity frequency doubling

Silvania F. Pereira, Min Xiao, J. D. Miller +2 more

We have generated squeezed states of light by the process of second harmonic conversion within an optical cavity resonant at both fundamental and harmonic frequencies. The experiment consists of a standing-wave cavity containing a crystal of lithium niobate doped with magnesium oxide and driven by the field from a frequency-stabilized Nd:YAG laser (incident power, ~10 mW). The total field reflected from the cavity illuminates a pair of high quantum efficiency photodiodes, whose individual photocurrents are summed. Observations of squeezing are made by analyzing the spectral density of fluctuations for this sum photo-current while the cavity detuning is scanned through resonance. An intensity regulator holds the reflected light intensity constant during the scan by control of the incident light level. Reductions in photocurrent fluctuations of 12% relative to the vacuum-state or shot-noise level are achieved for frequency offsets near 4 MHz. Since significantly higher degrees of squeezing are predicted by our theoretical analysis, we discuss those processes that currently limit the observed noise reduction, including phase noise produced by the intracavity crystal in the absence of nonlinear conversion.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Active versus passive squeezing by second-harmonic generation

Andrew G. White, Timothy C. Ralph, Hans‐A. Bachor

The characteristics of squeezed light generated by both passive (occurring in a cavity external to a laser) and active (occurring within a laser cavity) second-harmonic generation (SHG) are investigated and contrasted. Squeezing of both the fundamental and the second harmonic is discussed, and the issue of doubly versus singly resonant behavior is addressed. We examine passive squeezing by explicitly modeling the intrinsically noisy output of the pump laser and coupling it to a passive, multiport, lossy SHG cavity. Low-frequency degradation of the squeezing caused by the laser pump noise is predicted and provides a probable explanation for previous discrepancies between theory and experiment. Active squeezing is quantitatively modeled by a three-level laser model that retains all laser dynamics. Previously disparate predictions are reconciled. For one parameter set two regimes of squeezing are predicted: 50% squeezing at frequencies lower than the laser relaxation oscillation, and near-perfect squeezing at frequencies above. A particular problem of active squeezing is highlighted: The fast dephasing of the laser coherence introduces considerable excess noise likely to mask squeezing in experimental situations. We conclude that, although passive SHG is a practical source of squeezing, active SHG is unlikely to be so in the foreseeable future.

Journal of the Optical Society of America B•Jul 1, 1996•18 citations

Squeezing characteristics analysis of a fundamental-confined second-harmonic generation system by means of a self-consistent method

Joji Maeda, Kazuro Kikuchi

We discuss quantum-fluctuation characteristics of a second-harmonic generation system that uses an optical resonator to confine only the fundamental field. It was predicted that the available amount of squeezing is limited to 1.76 dB for the fundamental output and 9.54 dB for the second-harmonic output, respectively, irrespective of system parameters. However, these predictions are based on low-order perturbation theory and are unavailable if the nonlinear coupling between the fundamental and the second harmonic becomes large. We consider the spatial evolution of the fields and reveal that the maximum amount of squeezing depends on the cavity loss: Even an arbitrary amount of squeezing is possible for both the fundamental output and the second-harmonic output. We also consider the possibility of parametric oscillation of empty cavity modes pumped by the generated second harmonic and derive the following prediction: In a system that uses a type I phase-matched crystal, the oscillation of the side mode hardly occurs because of sum-frequency generation with the fundamental and scarcely imposes any limitations on squeezing. On the other hand, a system with a type II phase-matched crystal suffers from the oscillation of the polarization mode orthogonal to that of the fundamental input, and squeezing of the second-harmonic output is limited to 3 dB.

Journal of the Optical Society of America B•Mar 1, 1997•9 citations

Frequency-tunable squeezed light for spectroscopy

Eugene Simon Polzik, J. Carri, Harry J. Kimble

A frequency-tunable source of squeezed light would allow investigations of the atom-field interaction in a regime where fundamental new phenomena have been predicted.1 There are also opportunities for spectroscopy with sensitivity beyond the shot-noise limit. Toward these objectives, in our experiment we employ a single-frequency Ti-sapphire laser with tuning optimized around 852 nm (cesium resonance transition). The infrared output of the laser is frequency doubled in an external buildup cavity with a KNbO3 crystal as the nonlinear element. Efficient doubling provides 0.65 W of tunable blue output for 1.35 W of infrared input. This blue output is then used to pump an optical parametric oscillator (OPO) containing a second KNbO3 crystal for downconversion back to the infrared. The high power of the blue pump that we have achieved and the large nonlinearity of KNbO3 allows us to employ an OPO that is resonant only for the subharmonic infrared light. This design facilitates tuning of the OPO compared with the case in which the blue pump and the infrared are both resonant. The doubling cavity, OPO, and laser itself are locked relative to a stable reference cavity by an rf sideband technique, thus providing the possibility for tunability of the system with a single knob.

Annual Meeting Optical Society of America•Jan 1, 1991•0 citations
We analyze amplitude squeezing from a singly resonant frequency-doubling laser oscillating at a single frequency. In this laser system, the cavity loss depends on the intensity of the oscillating fundamental field, so that conventional analyses based on a mean-field approximation become invalid in a highly pumped regime. To avoid this inconvenience, we consider spatial evolution of fields both in a laser medium and in a nonlinear crystal. It is predicted for the first time that a combination of excess nonlinearity and modest laser saturation can increase the output noise. We propose novel indices to evaluate the possible noise enhancement and suggest a design rule for squeezed light generation.
We analyze the squeezing characteristics of a singly resonant second-harmonic-generation system, in which only the fundamental light is confined in a plain cavity resonator, with consideration for fundamental depletion in a nonlinear crystal. The system was analyzed under the mean-field approximation, which neglects the variation of the field in the crystal, and as much as 9.5 dB of squeezing was predicted in the second-harmonic output. On the basis of the self-consistent method, we analyze the system, which is driven by such an intense fundamental input that the mean-field approximation is not valid, and predict that an arbitrary amount of squeezing will be available in this regime.
We discuss different approaches to the generation of bright amplitude-squeezed light using second-order nonlinear effects in optical cavities. A 0.2 mW beam at 1064 nm exhibiting 4 dB squeezing has been generated using a phase-sensitive type-I parametric amplifier pumped by a frequency-doubled Nd:YAG laser. In applying frequency-doubling processes to the generation of amplitude-squeezed light, the appearance of parasitic parametric oscillation must be considered. This effect has been observed in a singly-resonant frequency doubler. We also describe recent developments in optical cavity design for doubly-resonant frequency-doubling. Finally, we show theoretically that phase-mismatched second-harmonic generation in an optical cavity can be employed to generate a strong effective Kerr nonlinearity. This system appears promising for achieving optical bistability and for generating squeezed light of high power. Keywords: Non-classical light, squeezed light, amplitude squeezing, nonlinear op...
We have generated squeezed states of light by the process of second harmonic conversion within an optical cavity resonant at both fundamental and harmonic frequencies. The experiment consists of a standing-wave cavity containing a crystal of lithium niobate doped with magnesium oxide and driven by the field from a frequency-stabilized Nd:YAG laser (incident power, ~10 mW). The total field reflected from the cavity illuminates a pair of high quantum efficiency photodiodes, whose individual photocurrents are summed. Observations of squeezing are made by analyzing the spectral density of fluctuations for this sum photo-current while the cavity detuning is scanned through resonance. An intensity regulator holds the reflected light intensity constant during the scan by control of the incident light level. Reductions in photocurrent fluctuations of 12% relative to the vacuum-state or shot-noise level are achieved for frequency offsets near 4 MHz. Since significantly higher degrees of squeezing are predicted by our theoretical analysis, we discuss those processes that currently limit the observed noise reduction, including phase noise produced by the intracavity crystal in the absence of nonlinear conversion.
The characteristics of squeezed light generated by both passive (occurring in a cavity external to a laser) and active (occurring within a laser cavity) second-harmonic generation (SHG) are investigated and contrasted. Squeezing of both the fundamental and the second harmonic is discussed, and the issue of doubly versus singly resonant behavior is addressed. We examine passive squeezing by explicitly modeling the intrinsically noisy output of the pump laser and coupling it to a passive, multiport, lossy SHG cavity. Low-frequency degradation of the squeezing caused by the laser pump noise is predicted and provides a probable explanation for previous discrepancies between theory and experiment. Active squeezing is quantitatively modeled by a three-level laser model that retains all laser dynamics. Previously disparate predictions are reconciled. For one parameter set two regimes of squeezing are predicted: 50% squeezing at frequencies lower than the laser relaxation oscillation, and near-perfect squeezing at frequencies above. A particular problem of active squeezing is highlighted: The fast dephasing of the laser coherence introduces considerable excess noise likely to mask squeezing in experimental situations. We conclude that, although passive SHG is a practical source of squeezing, active SHG is unlikely to be so in the foreseeable future.
We discuss quantum-fluctuation characteristics of a second-harmonic generation system that uses an optical resonator to confine only the fundamental field. It was predicted that the available amount of squeezing is limited to 1.76 dB for the fundamental output and 9.54 dB for the second-harmonic output, respectively, irrespective of system parameters. However, these predictions are based on low-order perturbation theory and are unavailable if the nonlinear coupling between the fundamental and the second harmonic becomes large. We consider the spatial evolution of the fields and reveal that the maximum amount of squeezing depends on the cavity loss: Even an arbitrary amount of squeezing is possible for both the fundamental output and the second-harmonic output. We also consider the possibility of parametric oscillation of empty cavity modes pumped by the generated second harmonic and derive the following prediction: In a system that uses a type I phase-matched crystal, the oscillation of the side mode hardly occurs because of sum-frequency generation with the fundamental and scarcely imposes any limitations on squeezing. On the other hand, a system with a type II phase-matched crystal suffers from the oscillation of the polarization mode orthogonal to that of the fundamental input, and squeezing of the second-harmonic output is limited to 3 dB.
A frequency-tunable source of squeezed light would allow investigations of the atom-field interaction in a regime where fundamental new phenomena have been predicted.1 There are also opportunities for spectroscopy with sensitivity beyond the shot-noise limit. Toward these objectives, in our experiment we employ a single-frequency Ti-sapphire laser with tuning optimized around 852 nm (cesium resonance transition). The infrared output of the laser is frequency doubled in an external buildup cavity with a KNbO3 crystal as the nonlinear element. Efficient doubling provides 0.65 W of tunable blue output for 1.35 W of infrared input. This blue output is then used to pump an optical parametric oscillator (OPO) containing a second KNbO3 crystal for downconversion back to the infrared. The high power of the blue pump that we have achieved and the large nonlinearity of KNbO3 allows us to employ an OPO that is resonant only for the subharmonic infrared light. This design facilitates tuning of the OPO compared with the case in which the blue pump and the infrared are both resonant. The doubling cavity, OPO, and laser itself are locked relative to a stable reference cavity by an rf sideband technique, thus providing the possibility for tunability of the system with a single knob.