Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Phase modulation with independent cavity-phase control in laser cooled clocks in space

William M. Klipstein, G.J. Dick, Steven R. Jefferts, Fred L. Walls

Published Nov 13, 2002• 10 citations
Publisher

Abstract

The standard interrogation technique in atomic beam clocks is square-wave frequency modulation(SWFM), which suffers a first-order sensitivity to vibrations as changes in the transit time of the atoms translates to perceived frequency errors. Square-wave phase modulation (SWPM) interrogation eliminates sensitivity to this noise. We present a particular scheme utilizing independent phase control of the two cavities. The technique is being considered for use with the Primary Atomic Reference Clock in Space (PARCS), a laser-cooled cesium clock scheduled to fly aboard the International Space Station in 2005. In addition to eliminating first-order sensitivity to vibrations, the minimum attack time now in this scheme is the Rabi pulse time (t), rather than the Ramsey time (T). This helps minimize dead time and the degradation of stability due to aliasing.

DOI
10.1109/freq.2001.956155

Related papers

Phase modulation for reduced vibration sensitivity in laser-cooled clocks in space

William M. Klipstein, G.J. Dick, Steven R. Jefferts +1 more

The standard interrogation technique in atomic beam clocks is square-wave frequency modulation (SWFM), which suffers a first order sensitivity to vibrations as changes in the transit time of the atoms translates to perceived frequency errors. Square-wave phase modulation (SWPM) interrogation eliminates sensitivity to this noise.

European Frequency and Time Forum•Mar 6, 2001•5 citations

Design Concept for the Microwave Interrogation Structure in PARCS

G.J. Dick, William M. Klipstein, Thomas P. Heavner +1 more

In this paper we describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the primary atomic reference clock in space (PARCS) experiment. The PARCS standard uses balls of cold atoms launched in a pulsed beam configuration. The microwave interrogation will take place in two independent high-Q (/spl sim/20,000) cavities operated in the TE/sub 011/ mode. The cavities will be operated off resonance by several linewidths, with a resonant coupling structure delivering the microwave to the two cavities. One persistent problem related to the end-to-end phase shift has been the extreme temperature sensitivity of the phase of inside the cavities to that just outside the cavities. The end-to-end phase shift must ultimately be known to around 3 microradians, and stable long enough to allow measurement of the shift as well as to allow normal clock operation. Operating the cavities off resonance reduces this sensitivity more strongly than reducing the cavity Q.

•Dec 5, 2002•0 citations

PARCS: A LASER-COOLED ATOMIC CLOCK IN SPACE

Thomas P. Heavner, Leo W. Hollberg, Steven R. Jefferts +13 more

This paper describes progress toward the development of a Primary Atomic Reference Clock in Space (PARCS) and reviews the scientific and technical objectives of the PARCS mission. PARCS is a collaborative effort involving the National Institute of Standards and Technology (NIST), the University of Colorado, the Jet Propulsion Laboratory (JPL), the Harvard Smithsonian Center for Astrophysics (SAO) and the Politecnico di Torino. Space systems for this experiment include a laser-cooled cesium atomic clock and a GPS frequency-comparison and orbit determination system, along with a hydrogen maser that serves as both a local oscillator for the cesium clock and a reference against which certain tests of gravitational theory can be made. In the microgravity environment of the International Space Station (ISS), cesium atoms can be launched more slowly through the clock's microwave cavity, thus significantly reducing a number of troubling effects (including several critical systematic effects), so clock performance can be substantially improved beyond that achieved on earth.

Symposium on Frequency Standards and Metrology•May 1, 2002•8 citations

Optical-clock local-oscillator universal interrogation protocol for zero probe-field-induced frequency-shifts

T. Zanon-Willette, R. Lefèvre, А. В. Тайченачев +1 more

Optical clock interrogation protocols, based on laser-pulse spectroscopy, are suffering from probe-induced frequency-shifts and their variations induced by laser power. Original Hyper-Ramsey probing scheme, which was proposed to alleviate those issues, does not apply below fractional frequency changes of 10-18when decoherence and relaxation by spontaneous emission or collisions are present. We present a universal interrogation protocol based on composite laser-pulses spectroscopy with phase-modulation for both fermionic and bosonic optical clocks, eliminating probe-induced frequency-shifts at all orders even in presence of various dissipative processes. This scheme, using a magic combination of ±π/4 and ±3π/4 phase-modulated generalized Hyper-Ramsey resonances, extremely robust to errors in laser parameters, can be applied to atomic, molecular and nuclear frequency metrology, mass spectrometry and precision spectroscopy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Phase stabilization of laser beams in a cold atom accelerometer

Nicole Byrne

A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.

•Jan 1, 2014•0 citations

Ramsey Spectroscopy with Displaced Frequency Jumps

M. Shuker, J. W. Pollock, Rodolphe Boudot +4 more

Sophisticated Ramsey-based interrogation protocols using composite laser pulse sequences have been recently proposed to provide next-generation high-precision atomic clocks with a near perfect elimination of frequency shifts induced during the atom-probing field interaction. We propose here a simple alternative approach to the autobalanced Ramsey interrogation protocol and demonstrate its application to a cold-atom microwave clock based on coherent population trapping (CPT). The main originality of the method, based on two consecutive Ramsey sequences with different dark periods, is to sample the central Ramsey fringes with frequency jumps finely adjusted by an additional frequency-displacement concomitant parameter, scaling as the inverse of the dark period. The advantage of this displaced frequency-jump Ramsey method is that the local oscillator (LO) frequency is used as a single physical variable to control both servo loops of the sequence, simplifying its implementation and avoiding noise associated with controlling the LO phase. When tested using a CPT cold-atom clock, the DFJR scheme reduces the sensitivity of the clock frequency to variations of the light shifts by more than an order of magnitude compared with the standard Ramsey interrogation. This simple method can be applied in a wide variety of Ramsey-spectroscopy based applications including frequency metrology with CPT-based and optical atomic clocks, mass spectrometry, and precision spectroscopy.

arXiv:1812.01703•Physical Review Letters•Mar 19, 2019•41 citations
The standard interrogation technique in atomic beam clocks is square-wave frequency modulation(SWFM), which suffers a first-order sensitivity to vibrations as changes in the transit time of the atoms translates to perceived frequency errors. Square-wave phase modulation (SWPM) interrogation eliminates sensitivity to this noise. We present a particular scheme utilizing independent phase control of the two cavities. The technique is being considered for use with the Primary Atomic Reference Clock in Space (PARCS), a laser-cooled cesium clock scheduled to fly aboard the International Space Station in 2005. In addition to eliminating first-order sensitivity to vibrations, the minimum attack time now in this scheme is the Rabi pulse time (t), rather than the Ramsey time (T). This helps minimize dead time and the degradation of stability due to aliasing.
In this paper we describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the primary atomic reference clock in space (PARCS) experiment. The PARCS standard uses balls of cold atoms launched in a pulsed beam configuration. The microwave interrogation will take place in two independent high-Q (/spl sim/20,000) cavities operated in the TE/sub 011/ mode. The cavities will be operated off resonance by several linewidths, with a resonant coupling structure delivering the microwave to the two cavities. One persistent problem related to the end-to-end phase shift has been the extreme temperature sensitivity of the phase of inside the cavities to that just outside the cavities. The end-to-end phase shift must ultimately be known to around 3 microradians, and stable long enough to allow measurement of the shift as well as to allow normal clock operation. Operating the cavities off resonance reduces this sensitivity more strongly than reducing the cavity Q.
This paper describes progress toward the development of a Primary Atomic Reference Clock in Space (PARCS) and reviews the scientific and technical objectives of the PARCS mission. PARCS is a collaborative effort involving the National Institute of Standards and Technology (NIST), the University of Colorado, the Jet Propulsion Laboratory (JPL), the Harvard Smithsonian Center for Astrophysics (SAO) and the Politecnico di Torino. Space systems for this experiment include a laser-cooled cesium atomic clock and a GPS frequency-comparison and orbit determination system, along with a hydrogen maser that serves as both a local oscillator for the cesium clock and a reference against which certain tests of gravitational theory can be made. In the microgravity environment of the International Space Station (ISS), cesium atoms can be launched more slowly through the clock's microwave cavity, thus significantly reducing a number of troubling effects (including several critical systematic effects), so clock performance can be substantially improved beyond that achieved on earth.
Optical clock interrogation protocols, based on laser-pulse spectroscopy, are suffering from probe-induced frequency-shifts and their variations induced by laser power. Original Hyper-Ramsey probing scheme, which was proposed to alleviate those issues, does not apply below fractional frequency changes of 10-18when decoherence and relaxation by spontaneous emission or collisions are present. We present a universal interrogation protocol based on composite laser-pulses spectroscopy with phase-modulation for both fermionic and bosonic optical clocks, eliminating probe-induced frequency-shifts at all orders even in presence of various dissipative processes. This scheme, using a magic combination of ±π/4 and ±3π/4 phase-modulated generalized Hyper-Ramsey resonances, extremely robust to errors in laser parameters, can be applied to atomic, molecular and nuclear frequency metrology, mass spectrometry and precision spectroscopy.
A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.
Sophisticated Ramsey-based interrogation protocols using composite laser pulse sequences have been recently proposed to provide next-generation high-precision atomic clocks with a near perfect elimination of frequency shifts induced during the atom-probing field interaction. We propose here a simple alternative approach to the autobalanced Ramsey interrogation protocol and demonstrate its application to a cold-atom microwave clock based on coherent population trapping (CPT). The main originality of the method, based on two consecutive Ramsey sequences with different dark periods, is to sample the central Ramsey fringes with frequency jumps finely adjusted by an additional frequency-displacement concomitant parameter, scaling as the inverse of the dark period. The advantage of this displaced frequency-jump Ramsey method is that the local oscillator (LO) frequency is used as a single physical variable to control both servo loops of the sequence, simplifying its implementation and avoiding noise associated with controlling the LO phase. When tested using a CPT cold-atom clock, the DFJR scheme reduces the sensitivity of the clock frequency to variations of the light shifts by more than an order of magnitude compared with the standard Ramsey interrogation. This simple method can be applied in a wide variety of Ramsey-spectroscopy based applications including frequency metrology with CPT-based and optical atomic clocks, mass spectrometry, and precision spectroscopy.