Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Focussing of momentum entangled photon pairs

Daniel Schlenk, Harald Weinfurter

Published Jun 1, 2009• 0 citations
Publisher

Abstract

The resolution of optical scanning microscopes is limited by the spot size of the scanning beam. It has been proposed that momentum entangled photons can be focused more tightly than classical light. We use a confocal microscope to measure the single and two photon distribution in the focus.
DOI
10.1109/cleoe-eqec.2009.5191628

Related papers

Breaking the diffraction limit using entanglement based microscopy

Daniel Schlenk, Harald Weinfurter

The resolution of optical scanning microscopes is limited by the spot size of the scanning beam. It has been proposed by Boto1 et al. and Nasr2 et al. that momentum entangled photons can be focused more tightly than classical light. Thus they should enable one to break the di ractive resolution limit. We report experiments measuring the spatial distribution of strong focussed momentum entangled photon pairs at a center wavelength of 812 nm from a spontaneous parametric down conversion source. Using a single gold stripe deposited on a glass surface as test object we observe a two-photon spot size as small as 194 nm, thereby beating the di raction limit even for conventional two-photon microscopy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 26, 2013•1 citation

Entangled-Photon Microscopy

Malvin Carl Teich, Bahaa E. A. Saleh

All forms of microscopy that have previously been developed rely on classical sources of light, which are relatively noisy by virtue of the photons arriving randomly in time and position. We propose a new technique of two-beam optical microscopy using a nonclassical light source comprising entangled photon pairs generated by the process of nonlinear optical parametric downconversion. Entangled-photon microscopy (EPM) has the potential for providing a substantial improvement over confocal laser scanning fluorescence microscopy (CLSM) as well as over two-photon laser scanning fluorescence microscopy (TPLSM). The latter technique relies on the proportionality of the two-photon absorption rate to the square of the optical photon-flux density, and makes use of a highly focused optical beam to localize the region from which fluorescence is observed. However, because the arrival of pairs of photons is accidental in TPLSM, relatively large values of the photon-flux density are required to achieve photon coincidence and hence absorption. This can lead to undesired phototoxicity and photobleaching of the specimen. EPM, in contrast, relies on the presence of highly correlated photon pairs, which enhances the two-photon absorption rate significantly and enables lower values of the photon-flux density to be used. The process depends linearly, rather than quadratically, on the photon-flux density. Further, the EPM interaction region can be controlled by the use of two beams, providing increased flexibility in the selection of desired regions of a specimen, and leading to enhanced axial and lateral resolution.

•Feb 27, 1997•0 citations

Twin-photon confocal microscopy

David S. Simon, Alexander V. Sergienko

A recently introduced two-channel confocal microscope with correlated detection promises up to 50% improvement in transverse spatial resolution [Simon, Sergienko, Optics Express 18, 9765 (2010)] via the use of photon correlations. Here we achieve similar results in a different manner, introducing a triple-confocal correlated microscope which exploits the correlations present in optical parametric amplifiers. It is based on tight focusing of pump radiation onto a thin sample positioned in front of a nonlinear crystal, followed by coincidence detection of signal and idler photons, each focused onto a pinhole. This approach offers further resolution enhancement in confocal microscopy.

arXiv:1005.1576•Optics Express•Oct 5, 2010•12 citations

Twin-Photon Correlated Confocal Microscopy

David S. Simon, Alexander V. Sergienko

We introduce two new devices, the correlation confocal and twin-photon microscopes. Like the standard two-photon confocal microscope, they use spatially-correlated photon pairs to improve lateral resolution, but with the correlation enforced in different manners.

•Jan 1, 2011•0 citations

Biological Microscopy with Undetected Photons

András Búzás, Elmar K. Wolff, M. G. Benedict +2 more

Novel imaging techniques utilizing nondegenerate, correlated photon pairs sparked intense interest during the last couple of years among scientists of the quantum optics community and beyond. It is a key property of such “ghost imaging” or “quantum interference” methods that they use those photons of the correlated pairs for imaging that never interacted with the sample, allowing detection in a spectral range different from that of the illumination of the object. Extensive applications of these techniques in spectroscopy and microscopy are envisioned, however, their limited spatial resolution to date has not yet supported real-life microscopic investigations of tiny biological objects. Here we report a modification of the method based on quantum interference by using a seeding laser and confocal scanning, that allows the improvement of the resolution of imaging with undetected photons by more than an order of magnitude, and we also present examples of application in the microscopy of biological samples.

arXiv:2006.14588•IEEE Access•Jan 1, 2020•22 citations

Enhancing Optical Microscopy with Quantum Entanglement

Xin Tong, Yide ide Zhang, Lihong ihong V. Wang

Drawing on the unique properties of entangled photons, quantum approaches can overcome the limitations of classical methods, enhance spatial resolution and reduce stray light and shot noise.

Optics and Photonics News•Oct 30, 2024•0 citations
The resolution of optical scanning microscopes is limited by the spot size of the scanning beam. It has been proposed by Boto1 et al. and Nasr2 et al. that momentum entangled photons can be focused more tightly than classical light. Thus they should enable one to break the di ractive resolution limit. We report experiments measuring the spatial distribution of strong focussed momentum entangled photon pairs at a center wavelength of 812 nm from a spontaneous parametric down conversion source. Using a single gold stripe deposited on a glass surface as test object we observe a two-photon spot size as small as 194 nm, thereby beating the di raction limit even for conventional two-photon microscopy.
All forms of microscopy that have previously been developed rely on classical sources of light, which are relatively noisy by virtue of the photons arriving randomly in time and position. We propose a new technique of two-beam optical microscopy using a nonclassical light source comprising entangled photon pairs generated by the process of nonlinear optical parametric downconversion. Entangled-photon microscopy (EPM) has the potential for providing a substantial improvement over confocal laser scanning fluorescence microscopy (CLSM) as well as over two-photon laser scanning fluorescence microscopy (TPLSM). The latter technique relies on the proportionality of the two-photon absorption rate to the square of the optical photon-flux density, and makes use of a highly focused optical beam to localize the region from which fluorescence is observed. However, because the arrival of pairs of photons is accidental in TPLSM, relatively large values of the photon-flux density are required to achieve photon coincidence and hence absorption. This can lead to undesired phototoxicity and photobleaching of the specimen. EPM, in contrast, relies on the presence of highly correlated photon pairs, which enhances the two-photon absorption rate significantly and enables lower values of the photon-flux density to be used. The process depends linearly, rather than quadratically, on the photon-flux density. Further, the EPM interaction region can be controlled by the use of two beams, providing increased flexibility in the selection of desired regions of a specimen, and leading to enhanced axial and lateral resolution.
A recently introduced two-channel confocal microscope with correlated detection promises up to 50% improvement in transverse spatial resolution [Simon, Sergienko, Optics Express 18, 9765 (2010)] via the use of photon correlations. Here we achieve similar results in a different manner, introducing a triple-confocal correlated microscope which exploits the correlations present in optical parametric amplifiers. It is based on tight focusing of pump radiation onto a thin sample positioned in front of a nonlinear crystal, followed by coincidence detection of signal and idler photons, each focused onto a pinhole. This approach offers further resolution enhancement in confocal microscopy.
Novel imaging techniques utilizing nondegenerate, correlated photon pairs sparked intense interest during the last couple of years among scientists of the quantum optics community and beyond. It is a key property of such “ghost imaging” or “quantum interference” methods that they use those photons of the correlated pairs for imaging that never interacted with the sample, allowing detection in a spectral range different from that of the illumination of the object. Extensive applications of these techniques in spectroscopy and microscopy are envisioned, however, their limited spatial resolution to date has not yet supported real-life microscopic investigations of tiny biological objects. Here we report a modification of the method based on quantum interference by using a seeding laser and confocal scanning, that allows the improvement of the resolution of imaging with undetected photons by more than an order of magnitude, and we also present examples of application in the microscopy of biological samples.