Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...

Uncooled, millimeter-scale atomic magnetometers with femtotesla sensitivity

John E. Kitching, Svenja A. Knappe, W. C. Griffith, Jan Preusser, Vladislav P. Gerginov, Peter D. D. Schwindt, Vishal Shah, Ricardo Jiménez-Martínez

Published Oct 1, 2009• 5 citations
Publisher

Abstract

We summarize recent results at NIST to develop high-performance yet highly miniaturized magnetic sensors based on atomic vapors confined in microfabricated alkali vapor cells. These sensors currently achieve sensitivities in the range of a few tens of femtotesla in a 1 Hz bandwidth in detection volumes of about 1 mm3. They require no cooling and only a small amount of heating, making them ideal for deployment in remote, power starved locations.

DOI
10.1109/icsens.2009.5398417

Related papers

A simple spin-exchange-relaxation-free atomic magnetometer using microfabricated vapor cell

Vishal Shah, Peter D. D. Schwindt, Svenja A. Knappe +1 more

We demonstrate an atomic magnetometer with a sensitivity below 100 fT/√Hz, using a millimeter-scale microfabricated alkali vapor cell and a single low-power diode laser. This work suggests that compact, low-power, highly sensitive magnetometers are feasible.

Quantum Electronics and Laser Science Conference•May 6, 2007•1 citation

Chip-Scale Atomic Devices Based on Microfabricated Alkali Vapor Cells

John E. Kitching, Svenja A. Knappe, John Moreland +8 more

We describe recent progress in the development of millimeter-scale instruments based on alkali atom vapor cells implemented with microfabrication techniques. Because of their small size and correspondingly low power requirements, these "chip-scale" atomic clocks and magnetometers have the potential to bring atomically precise instrumentation to portable, battery-operated systems such as GPS receivers, remote sensors and wireless communication devices. In addition, wafer-level processing and assembly potentially allows for very low cost per instrument if high volumes are produced.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•1 citation

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

Optics Express•Dec 9, 2010•183 citations

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

APS•Mar 1, 2010•0 citations

A low-power, high-sensitivity micromachined optical magnetometer

Rahul R. Mhaskar, Svenja A. Knappe, John E. Kitching

We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.

Applied Physics Letters•Dec 10, 2012•175 citations

Chip-scale atomic devices at NIST

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +9 more

We provide an overview of our research on chip-scale atomic devices. By miniaturizing optical setups based on precision spectroscopy, we have developed small atomic sensors and atomic references such as atomic clocks, atomic magnetometers, and optical wavelength references. We have integrated microfabricated alkali vapor cells with small low-power lasers, micro-optics, and low-power microwave oscillators. As a result, we anticipate that atomic stability can be achieved with small size, low cost, battery-operated devices. Advances in fabrication methods and performance are presented.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2007•6 citations
We summarize recent results at NIST to develop high-performance yet highly miniaturized magnetic sensors based on atomic vapors confined in microfabricated alkali vapor cells. These sensors currently achieve sensitivities in the range of a few tens of femtotesla in a 1 Hz bandwidth in detection volumes of about 1 mm3. They require no cooling and only a small amount of heating, making them ideal for deployment in remote, power starved locations.
We describe recent progress in the development of millimeter-scale instruments based on alkali atom vapor cells implemented with microfabrication techniques. Because of their small size and correspondingly low power requirements, these "chip-scale" atomic clocks and magnetometers have the potential to bring atomically precise instrumentation to portable, battery-operated systems such as GPS receivers, remote sensors and wireless communication devices. In addition, wafer-level processing and assembly potentially allows for very low cost per instrument if high volumes are produced.
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.
We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.
We provide an overview of our research on chip-scale atomic devices. By miniaturizing optical setups based on precision spectroscopy, we have developed small atomic sensors and atomic references such as atomic clocks, atomic magnetometers, and optical wavelength references. We have integrated microfabricated alkali vapor cells with small low-power lasers, micro-optics, and low-power microwave oscillators. As a result, we anticipate that atomic stability can be achieved with small size, low cost, battery-operated devices. Advances in fabrication methods and performance are presented.