Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Recent progress in quantum and nonlinear optical lithography

Robert W. Boyd, Sean J. Bentley

Published Feb 21, 2006• 30 citations
Publisher

Abstract

We review the status of the field of quantum lithography, that is, the use of quantum-mechanical effects to write lithographic features with resolution finer than that achievable according to the Rayleigh criterion. In particular, we first review the original quantum lithography proposal by Boto et al., and we then describe the status of research aimed at realizing this process.

DOI
10.1080/09500340500283722

Related papers

Progress in quantum lithography

Robert W. Boyd, Hye Jeong Chang, Heedeuk Shin +1 more

We review our progress toward implementing the proposal of Boto et al. (Phys. Rev. Lett. 85, 2733-2736, 2000) for using entangled photons to increase the spatial resolution of the process of interferometric photolithography beyond that of the standard Rayleigh limit.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 18, 2005•0 citations

A study of quantum lithography for diffraction limit

Sang-Kon Kim

Since the diffraction limit of Rayleigh criterion hardly creates finer features, the development of technologies beyond the diffraction limit is a key merit without the shorter-wavelength source tool. In this paper, nano-phenomena to beat the Rayleigh criterion are described. For quantum lithography, collective behaviour of N-photon entangled states is modeled and simulated to show the effect of photon entangled states to 3-dimensional arbitrary pattern formation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 10, 2011•1 citation

Quantum-interferometric optical lithography: Towards arbitrary two-dimensional patterns

Pieter Kok, Agedi N. Boto, Daniel S. Abrams +3 more

As demonstrated by Boto et al. [Phys. Rev. Lett. 85, 2733 (2000)], quantum lithography offers an increase in resolution below the diffraction limit. Here, we generalize this procedure in order to create patterns in one and two dimensions. This renders quantum lithography a potentially useful tool in nanotechnology.

arXiv:quant-ph/0011088•Physical Review A•May 9, 2001•127 citations

Quantum lithography: Toward entangled-photon optics

Luis Lorenzo Sánchez-Soto, Gunnar G. Bjork, Jonas Söderholm

The advantages of using nonclassical states of light for optical imaging are discussed, with special emphasis on the new field of quantum optical lithography. The classical resolution limit given by the Rayleigh criterion is approximately half of the optical wavelength. However, it has been argued that, by using special quantum states of light and a multiphoton-sensitive material or detector, this limit can be broken. Here, a brief and rigorous overview of this problem is provided, some particularly widespread misconceptions are addressed, and turning quantum lithography into a practical technology is discussed.

Optics and Spectroscopy•May 1, 2003•1 citation

Quantum entanglement for optical lithography and microscopy beyond the Rayleigh limit

Sean J. Bentley, Robert W. Boyd, Elna M. Nagasako +1 more

Summary form only given. Recently, Boto et al. (see Phys. Rev. Lett., vol. 85, p. 2773, 2000) showed that using N entangled photons and an N-photon responsive lithographic recording medium, one could potentially write lithographic gratings with a resolution that is N times better than the classical Rayleigh criterion. An anticipated experimental difficulty is that such beams are weak, yet strong fields are needed to excite the N-photon absorption process. For the case of N=2, which was described in detail by Boto et al., we propose a method to overcome this problem. We also propose to use this idea "in reverse" to perform microscopy with better resolution than aloowed by the Rayleigh limit.

Quantum Electronics and Laser Science Conference•Nov 13, 2002•2 citations

Beyond the Rayleigh Limit in Optical Lithography

Muhammad Suhail Zubairy

It is well known that the classical schemes for microscopy and lithography are restricted by the diffraction limit. The precision with which a pattern could be etched in interference lithography is limited by the wavelength of the light. In recent years, a number of schemes have been proposed via quantum interferometry to improve the resolution. Some of these schemes are based on quantum entanglement and multiphoton processes.

Frontiers in Optics•Jan 1, 2011•0 citations
We review the status of the field of quantum lithography, that is, the use of quantum-mechanical effects to write lithographic features with resolution finer than that achievable according to the Rayleigh criterion. In particular, we first review the original quantum lithography proposal by Boto et al., and we then describe the status of research aimed at realizing this process.
The advantages of using nonclassical states of light for optical imaging are discussed, with special emphasis on the new field of quantum optical lithography. The classical resolution limit given by the Rayleigh criterion is approximately half of the optical wavelength. However, it has been argued that, by using special quantum states of light and a multiphoton-sensitive material or detector, this limit can be broken. Here, a brief and rigorous overview of this problem is provided, some particularly widespread misconceptions are addressed, and turning quantum lithography into a practical technology is discussed.
Summary form only given. Recently, Boto et al. (see Phys. Rev. Lett., vol. 85, p. 2773, 2000) showed that using N entangled photons and an N-photon responsive lithographic recording medium, one could potentially write lithographic gratings with a resolution that is N times better than the classical Rayleigh criterion. An anticipated experimental difficulty is that such beams are weak, yet strong fields are needed to excite the N-photon absorption process. For the case of N=2, which was described in detail by Boto et al., we propose a method to overcome this problem. We also propose to use this idea "in reverse" to perform microscopy with better resolution than aloowed by the Rayleigh limit.