Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Space cold atom clock with counter-propagating atoms

Desheng Lü, Bin Wang, Tang Li, Liang Liu

Published Apr 1, 2009• 0 citations
Publisher

Abstract

We discuss the feasibility to realize a space cold atom clock with counter-propagating cold atoms in microgravity. The design of the space clock is based on atomic beam clock with a Ramsey cavity, except a magneto-optical trap (MOT) is placed at each side. Cold atoms are launched from MOTs at both side of the clock simultaneously and move at counter-direction towards each other. The velocity of launched atoms is precisely controlled to the Ramsauer-Townsend resonance so that no additional collision frequency shift is taken place. Such a configuration can efficiently cancel the frequency shift led from cavity phase shift and increase the signal to noise.

DOI
10.1109/freq.2009.5168345

Related papers

Cold Atom Space Clock with Counter-Propagating Atoms

Desheng Lv, Bin Wang, Tang Li +1 more

We discuss the feasibility to realize a space cold atom clock with counter-propagating cold atoms in microgravity. The design of the space clock is based on atomic beam clock with a Ramsey cavity, except a magneto-optical trap (MOT) is placed at each side. Cold atoms are launched from MOTs at both side of the clock simultaneously and move at counter-direction towards each other. The velocity of launched atoms is precisely controlled to the Ramsauer-Townsend resonance so that no additional collision frequency shift is taken place. Such a configuration can efficiently cancel the frequency shift led from cavity phase shift and increase the signal to noise.

arXiv:0902.3066•Feb 18, 2009•1 citation

利用对射原子团的空间冷原子钟

Desheng Lv, Bin Wang, Tang Li +1 more

We discuss the feasibility of realizing a cold atom space clock with counter-propagating cold atoms in microgravity. The design of the space clock is based on an atomic beam clock with Ramsey cavity, except that magneto-optical trap (MOT) is placed at each side. Cold atoms are launched simultaneously from the MOTs at both sides of the clock and they move at the counter-direction towards each other. The velocity of the launched atoms is precisely controlled to Ramsauer-Townsend resonance so that no additional collision frequency shift takes place. Such configuration can efficiently cancel the frequency shift resulting from cavity phase shift and increase the signal-to-noise ratio (SNR).

Chinese Optics Letters•Jan 1, 2010•2 citations

Compact, Continuous-Beam, Cold-Atom Clock for Satellite Applications

H. Wang, Walter F. Buell

Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. The requirements for an atomic clock vary significantly depending on the application, and for many space systems, compactness and robust design are at a premium, and stability dominates over absolute accuracy. We report on progress with our design for a compact laser-cooled Cs- beam atomic clock suitable for satellite applications such as GPS. The basic design features a continuous, cold atomic beam extracted from a magneto-optic trap (MOT). This cold atomic beam is then to be used in a laser-pumped Ramsey clock, with the clock signal derived from either a microwave C-field or, alternatively, by Raman resonance between the Ramsey fields. In order to reduce light shifts from the MOT light and improve signal-to-noise, the atomic beam will be optically deflected and transversely cooled upon extraction from the MOT. We estimate that the shot-noise-limited stability achievable with this physics package can be 2 to 3 orders of magnitude better than current Cs-beam clocks used in satellite applications. We present our experimental progress towards a working frequency standard, including characterization of our six-beam magneto-optic cold atom trap and production and characterization of a cold atomic beam.

•Jun 30, 2002•1 citation

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

A cold-atom Ramsey clock with a low volume physics package

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

arXiv:2305.02944•Scientific Reports•Jan 9, 2024•23 citations

Progress Toward an Atomic Clock Based on a Continuous Cold Rubidium Beam

Zhixin Meng, Peiqiang Yan, Xiaojie Li +1 more

We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2020•1 citation
We discuss the feasibility to realize a space cold atom clock with counter-propagating cold atoms in microgravity. The design of the space clock is based on atomic beam clock with a Ramsey cavity, except a magneto-optical trap (MOT) is placed at each side. Cold atoms are launched from MOTs at both side of the clock simultaneously and move at counter-direction towards each other. The velocity of launched atoms is precisely controlled to the Ramsauer-Townsend resonance so that no additional collision frequency shift is taken place. Such a configuration can efficiently cancel the frequency shift led from cavity phase shift and increase the signal to noise.
We discuss the feasibility to realize a space cold atom clock with counter-propagating cold atoms in microgravity. The design of the space clock is based on atomic beam clock with a Ramsey cavity, except a magneto-optical trap (MOT) is placed at each side. Cold atoms are launched from MOTs at both side of the clock simultaneously and move at counter-direction towards each other. The velocity of launched atoms is precisely controlled to the Ramsauer-Townsend resonance so that no additional collision frequency shift is taken place. Such a configuration can efficiently cancel the frequency shift led from cavity phase shift and increase the signal to noise.
We discuss the feasibility of realizing a cold atom space clock with counter-propagating cold atoms in microgravity. The design of the space clock is based on an atomic beam clock with Ramsey cavity, except that magneto-optical trap (MOT) is placed at each side. Cold atoms are launched simultaneously from the MOTs at both sides of the clock and they move at the counter-direction towards each other. The velocity of the launched atoms is precisely controlled to Ramsauer-Townsend resonance so that no additional collision frequency shift takes place. Such configuration can efficiently cancel the frequency shift resulting from cavity phase shift and increase the signal-to-noise ratio (SNR).
Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. The requirements for an atomic clock vary significantly depending on the application, and for many space systems, compactness and robust design are at a premium, and stability dominates over absolute accuracy. We report on progress with our design for a compact laser-cooled Cs- beam atomic clock suitable for satellite applications such as GPS. The basic design features a continuous, cold atomic beam extracted from a magneto-optic trap (MOT). This cold atomic beam is then to be used in a laser-pumped Ramsey clock, with the clock signal derived from either a microwave C-field or, alternatively, by Raman resonance between the Ramsey fields. In order to reduce light shifts from the MOT light and improve signal-to-noise, the atomic beam will be optically deflected and transversely cooled upon extraction from the MOT. We estimate that the shot-noise-limited stability achievable with this physics package can be 2 to 3 orders of magnitude better than current Cs-beam clocks used in satellite applications. We present our experimental progress towards a working frequency standard, including characterization of our six-beam magneto-optic cold atom trap and production and characterization of a cold atomic beam.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.