Physical Review Letters

Cavity-Enhanced Parity-Nonconserving Optical Rotation in Metastable Xe and Hg

Lykourgos Bougas, George E. Katsoprinakis, Wolf von Klitzing, Jonathan R. Sapirstein, T. Peter Rakitzis

Published May 25, 2012• 34 citations
Publisher

Abstract

We propose the measurement of cavity-enhanced parity-nonconserving (PNC) optical rotation in several transitions of metastable Xe and Hg, including Xe ${(}^{2}{P}_{3/2}^{o})6s\text{ }^{2}[3/2{]}_{2}^{o}\ensuremath{\rightarrow}{(}^{2}{P}_{1/2}^{o})6s\text{ }^{2}[1/2{]}_{1}^{o}$ and Hg $6s6p\text{ }^{3}P_{2}^{o}\ensuremath{\rightarrow}6s6p\text{ }^{1}P_{1}^{o}$, with calculated amplitude ratios of ${E}_{1}^{\mathrm{PNC}}/M1=11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ and $10\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$, respectively. We demonstrate the use of a high-finesse bow-tie cavity with counterpropagating beams and a longitudinal magnetic field, which allows the absolute measurement of chiral optical rotation, with a path length enhancement of about ${10}^{4}$, necessary for PNC measurement from available column densities of ${10}^{14}\text{ }\text{ }{\mathrm{cm}}^{\ensuremath{-}2}$ for metastable Xe or Hg. Rapid PNC-signal reversal, allowing robust background subtraction, is achieved by shifting the cavity resonance to an opposite polarization mode or by inverting the magnetic field. The precise measurement of isotope and nuclear-spin dependent ${E}_{1}^{\mathrm{PNC}}$ amplitudes provides a sensitive low-energy test of the standard model.

DOI
10.1103/physrevlett.108.210801

Related papers

Studies of Electromagnetically Induced Transparency in Thallium Vapor and Possible Utility for Measuring Atomic Parity Nonconservation

Alexander D. Cronin, Richard B. Warrington, S. K. Lamoreaux +1 more

Motivated by the potential use of electromagnetically induced transparency (EIT) to measure atomic parity nonconservation (PNC), we have studied EIT and associated optical rotation for a three-level system in thallium vapor. EIT allows sub-Doppler resolution of the ${6P}_{1/2}\ensuremath{\rightarrow}{6P}_{3/2}$ mixed magnetic dipole, electric quadrupole transition at $1.28\ensuremath{\mu}\mathrm{m}$ when $0.535\ensuremath{-}\ensuremath{\mu}\mathrm{m}$ radiation acts on the ${6P}_{3/2}\ensuremath{\rightarrow}{7S}_{1/2}$ transition. Our measurements include rotation due to electromagnetically induced birefringence and Faraday rotation perturbed by EIT. We also identify a new method for determining the amplitude ratio $E2/M1$ for the $1.28\ensuremath{-}\ensuremath{\mu}\mathrm{m}$ transition. The possible advantages of an EIT technique for measuring atomic PNC are discussed in the context of our results.

Physical Review Letters•Apr 27, 1998•29 citations

Cavity-Enhanced Parity-Nonconserving Optical Rotation in Hg, Xe, and I

Lykourgos Bougas, G. E. Katsorinakis, T. Peter Rakitzis

Author Institution: Department of Physics, University of Crete, and Institute of Electronic Structure and Laser, Foundation for Research and Technology-Hellas 71110 Heraklion-Crete, Greece

mss•Jun 1, 2013•0 citations

Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy

R. Engeln, Giel Berden, Rudy Peeters +1 more

It is experimentally demonstrated that a narrow band continuous wave (cw) light source can be used in combination with a high-finesse optically stable cavity to perform sensitive, high-resolution direct absorption and optical rotation spectroscopy in an amazingly simple experimental setup, using ideas from the field of cavity ring down spectroscopy. Light from a scanning narrow band cw laser is coupled into the cavity via accidental coincidences of the laser frequency with the frequency of one of the multitude of modes of the cavity. The absorption and polarization rotation information is extracted from a measurement of the time-integrated light intensity leaking out of the cavity as a function of laser wavelength.

Review of Scientific Instruments•Nov 1, 1998•354 citations

Analysis of two-pathway coherent control for precision measurement of weak optical transitions

D. Antypas, Daniel S. Elliott

We present a new technique based on two-pathway optical coherent control for the sensitive detection and precise measurement of highly-forbidden transitions in atomic systems. Specifically, we show that ($ω$, 2$ω$) coherent control can be applied to the measurement of the magnetic dipole and electroweak parity nonconserving amplitudes in atomic cesium, with the principal advantage of reduced systematic errors related to field reversals often encountered in previous measurements of these effects. We present a complete analysis in one specific geometry, and discuss prospects for improved laboratory determinations of these weak transition amplitudes.

arXiv:1001.2465•Jan 14, 2010•0 citations

Nuclear magnetic resonance gyroscope

David M. Pepper, H. T. M. Wang

A study of the physics of a nuclear magnetic resonance gyroscope is described. Experimental results in nuclear polarization and relaxation in 3He are obtained using an optical pumping apparatus and a high resolution rf spectroscopic technique. Polarization in the metastable states of the heavy noble gases (20, 21 Ne, 129, 132 Xe) was observed using a similar optical pumping apparatus. A sensitive detection method based on optical polarization of an excited state transition is developed and compared with the conventional method of monitoring optical transmission through the optical pumping cell. A new concept for the optical pumping of odd-mass-numbered heavy noble was isotopes to provide for ground-state nuclear polarization is discussed. Significant polarization in excited state neon was observed via collisional transfer from optically pumped helium in a cell filled with a mixture of helium and neon isotopes. The measured polarization was essentially independent of the isotopic composition. (Author)

STIN•Dec 1, 1982•1 citation

Precision of cavity-enhanced optical rotation measurements

Joaquín Guimbao Gaspar

The signal to noise ratio in atomic magnetometry is fundamentally limited by the optical depth of the atomic ensemble. During the last decade, different technics for optical depth enhancement has been developed by several groups, some of them involving the implementation of an optical cavity. This thesis evaluates the performance of such an implementation by the polarization read out noise analysis of an optical cavity with similar characteristics as the already implemented by other groups. We obtained an estimated value for the signal to noise ratio enhancement with a cavity of 814 Finesse, and we studied the behaviour of the different sources of polarization noise in this system.

•Jul 22, 2016•0 citations
We propose the measurement of cavity-enhanced parity-nonconserving (PNC) optical rotation in several transitions of metastable Xe and Hg, including Xe (2P3/2o)6s 2[3/2]2o\ensuremath→(2P1/2o)6s 2[1/2]1o{(}^{2}{P}_{3/2}^{o})6s\text{ }^{2}[3/2{]}_{2}^{o}\ensuremath{\rightarrow}{(}^{2}{P}_{1/2}^{o})6s\text{ }^{2}[1/2{]}_{1}^{o}(2P3/2o​)6s 2[3/2]2o​\ensuremath→(2P1/2o​)6s 2[1/2]1o​ and Hg 6s6p 3P2o\ensuremath→6s6p 1P1o6s6p\text{ }^{3}P_{2}^{o}\ensuremath{\rightarrow}6s6p\text{ }^{1}P_{1}^{o}6s6p 3P2o​\ensuremath→6s6p 1P1o​, with calculated amplitude ratios of E1PNC/M1=11\ifmmode×\else\texttimes\fi10\ensuremath−8{E}_{1}^{\mathrm{PNC}}/M1=11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}E1PNC​/M1=11\ifmmode×\else\texttimes\fi10\ensuremath−8 and 10\ifmmode×\else\texttimes\fi10\ensuremath−810\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}10\ifmmode×\else\texttimes\fi10\ensuremath−8, respectively. We demonstrate the use of a high-finesse bow-tie cavity with counterpropagating beams and a longitudinal magnetic field, which allows the absolute measurement of chiral optical rotation, with a path length enhancement of about 104{10}^{4}104, necessary for PNC measurement from available column densities of 1014  cm\ensuremath−2{10}^{14}\text{ }\text{ }{\mathrm{cm}}^{\ensuremath{-}2}1014  cm\ensuremath−2 for metastable Xe or Hg. Rapid PNC-signal reversal, allowing robust background subtraction, is achieved by shifting the cavity resonance to an opposite polarization mode or by inverting the magnetic field. The precise measurement of isotope and nuclear-spin dependent E1PNC{E}_{1}^{\mathrm{PNC}}E1PNC​ amplitudes provides a sensitive low-energy test of the standard model.
Motivated by the potential use of electromagnetically induced transparency (EIT) to measure atomic parity nonconservation (PNC), we have studied EIT and associated optical rotation for a three-level system in thallium vapor. EIT allows sub-Doppler resolution of the ${6P}_{1/2}\ensuremath{\rightarrow}{6P}_{3/2}$ mixed magnetic dipole, electric quadrupole transition at $1.28\ensuremath{\mu}\mathrm{m}$ when $0.535\ensuremath{-}\ensuremath{\mu}\mathrm{m}$ radiation acts on the ${6P}_{3/2}\ensuremath{\rightarrow}{7S}_{1/2}$ transition. Our measurements include rotation due to electromagnetically induced birefringence and Faraday rotation perturbed by EIT. We also identify a new method for determining the amplitude ratio E2/M1E2/M1E2/M1 for the $1.28\ensuremath{-}\ensuremath{\mu}\mathrm{m}$ transition. The possible advantages of an EIT technique for measuring atomic PNC are discussed in the context of our results.
It is experimentally demonstrated that a narrow band continuous wave (cw) light source can be used in combination with a high-finesse optically stable cavity to perform sensitive, high-resolution direct absorption and optical rotation spectroscopy in an amazingly simple experimental setup, using ideas from the field of cavity ring down spectroscopy. Light from a scanning narrow band cw laser is coupled into the cavity via accidental coincidences of the laser frequency with the frequency of one of the multitude of modes of the cavity. The absorption and polarization rotation information is extracted from a measurement of the time-integrated light intensity leaking out of the cavity as a function of laser wavelength.
We present a new technique based on two-pathway optical coherent control for the sensitive detection and precise measurement of highly-forbidden transitions in atomic systems. Specifically, we show that (ωωω, 2ωωω) coherent control can be applied to the measurement of the magnetic dipole and electroweak parity nonconserving amplitudes in atomic cesium, with the principal advantage of reduced systematic errors related to field reversals often encountered in previous measurements of these effects. We present a complete analysis in one specific geometry, and discuss prospects for improved laboratory determinations of these weak transition amplitudes.
A study of the physics of a nuclear magnetic resonance gyroscope is described. Experimental results in nuclear polarization and relaxation in 3He are obtained using an optical pumping apparatus and a high resolution rf spectroscopic technique. Polarization in the metastable states of the heavy noble gases (20, 21 Ne, 129, 132 Xe) was observed using a similar optical pumping apparatus. A sensitive detection method based on optical polarization of an excited state transition is developed and compared with the conventional method of monitoring optical transmission through the optical pumping cell. A new concept for the optical pumping of odd-mass-numbered heavy noble was isotopes to provide for ground-state nuclear polarization is discussed. Significant polarization in excited state neon was observed via collisional transfer from optically pumped helium in a cell filled with a mixture of helium and neon isotopes. The measured polarization was essentially independent of the isotopic composition. (Author)
The signal to noise ratio in atomic magnetometry is fundamentally limited by the optical depth of the atomic ensemble. During the last decade, different technics for optical depth enhancement has been developed by several groups, some of them involving the implementation of an optical cavity. This thesis evaluates the performance of such an implementation by the polarization read out noise analysis of an optical cavity with similar characteristics as the already implemented by other groups. We obtained an estimated value for the signal to noise ratio enhancement with a cavity of 814 Finesse, and we studied the behaviour of the different sources of polarization noise in this system.