Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Progress toward a precision measurement of the atomic recoil frequency using an echo-type atom interferometer

B. Barrett, Scott Beattie, Adam C. Carew, I. Y. Chan, Carson Mok, Itay Yavin, Anantharaman Kumarakrishnan

Published Sep 10, 2010• 0 citations
Publisher

Abstract

We discuss progress towards a precision measurement of the atomic recoil frequency in 85Rb using an echo-type atom interferometer. We report a single measurement precision of ~ 300 ppb on a timescale of ~ 50 ms.
DOI
10.1117/12.879761

Related papers

Progress Toward a Precision Measurement of the Atomic Recoil Frequency Using A Grating Echo Interferometer

Anantharaman Kumarakrishnan, B. Barrett, Adam C. Carew

We discuss progress toward a precise measurement of the atomic recoil frequency using a grating-echo atom interferometer and a non-magnetic apparatus that permits interferometer signal lifetimes approaching the transit time limit.

Frontiers in Optics•Jan 1, 2012•0 citations

Prospects for Precise Measurements with Echo Atom Interferometry

B. Barrett, Adam C. Carew, Hermina C. Beica +3 more

Echo atom interferometers have emerged as interesting alternatives to Raman interferometers for the realization of precise measurements of the gravitational acceleration g and the determination of the atomic fine structure through measurements of the atomic recoil frequency ω q . Here we review the development of different configurations of echo interferometers that are best suited to achieve these goals. We describe experiments that utilize near-resonant excitation of laser-cooled rubidium atoms by a sequence of standing wave pulses to measure ω q with a statistical uncertainty of 37 parts per billion (ppb) on a time scale of ∼50 ms and g with a statistical precision of 75 ppb. Related coherent transient techniques that have achieved the most statistically precise measurements of atomic g-factor ratios are also outlined. We discuss the reduction of prominent systematic effects in these experiments using off-resonant excitation by low-cost, high-power lasers.

arXiv:1606.06831•Atoms•Jun 27, 2016•23 citations

Measuring the atomic recoil frequency using a modified grating-echo atom interferometer

B. Barrett, A. Carew, Scott Beattie +1 more

We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per ${10}^{9}$ (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per ${10}^{6}$ (ppm). We describe methods of reducing these systematic errors.

arXiv:1209.5624•Physical Review A•Mar 25, 2013•22 citations

Progress towards a precision measurement of atomic recoil frequency using an echo interferometer

B. Barrett, Adam C. Carew, Scott Beattie +4 more

Bulletin of the American Physical Society•May 28, 2010•0 citations

Technique for measuring atomic recoil frequency using coherence functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Physical Review A•Feb 13, 2009•13 citations

Recoil frequency measurement with ppb-level uncertainty by Li6 atom interferometer

Yang Rui, Liang Zhang, Rui Li +5 more

We report a first realization of cold atom interferometers with the lightest alkali metal $^{6}\mathrm{Li}$ atoms and precisely measure the recoil frequency. The atoms are cooled to approach the half of the photon-recoil limit by using a narrow $2S\ensuremath{\rightarrow}3P$ ultraviolet transition. A ``magic'' magnetically insensitive state, a high-efficiency state preparation, and a frequency-insensitive Raman coupling are developed to overcome the challenges from the half-integer spin and hyperfine interaction of atoms. A conjugated $\text{Ramsey-Bord}\stackrel{\ifmmode \acute{}\else \'{}\fi{}}{\mathrm{e}}$ interferometer with crossed Raman beams is realized with a coherence time longer than 2.3 ms. The four sets of interferometers developed using geometric relations greatly eliminate the error from the angle between Raman beams. The measured recoil frequency is ${\ensuremath{\omega}}_{r}=2\ensuremath{\pi}\ifmmode\times\else\texttimes\fi{}73\phantom{\rule{0.16em}{0ex}}672.789\phantom{\rule{0.16em}{0ex}}(36)$ Hz, representing the most precise measurement of the recoil frequency of $^{6}\mathrm{Li}$ by using the atom interferometer so far. The realized $^{6}\mathrm{Li}$ cold atom interferometer is not only an effective supplement to the existing interferometers, but also provides a good candidate in precision measurement owing to its low mass and high recoil frequency.

Physical Review Research•Apr 24, 2023•6 citations
Echo atom interferometers have emerged as interesting alternatives to Raman interferometers for the realization of precise measurements of the gravitational acceleration g and the determination of the atomic fine structure through measurements of the atomic recoil frequency ω q . Here we review the development of different configurations of echo interferometers that are best suited to achieve these goals. We describe experiments that utilize near-resonant excitation of laser-cooled rubidium atoms by a sequence of standing wave pulses to measure ω q with a statistical uncertainty of 37 parts per billion (ppb) on a time scale of ∼50 ms and g with a statistical precision of 75 ppb. Related coherent transient techniques that have achieved the most statistically precise measurements of atomic g-factor ratios are also outlined. We discuss the reduction of prominent systematic effects in these experiments using off-resonant excitation by low-cost, high-power lasers.
We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per 109{10}^{9}109 (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per 106{10}^{6}106 (ppm). We describe methods of reducing these systematic errors.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We report a first realization of cold atom interferometers with the lightest alkali metal 6Li^{6}\mathrm{Li}6Li atoms and precisely measure the recoil frequency. The atoms are cooled to approach the half of the photon-recoil limit by using a narrow $2S\ensuremath{\rightarrow}3P$ ultraviolet transition. A ``magic'' magnetically insensitive state, a high-efficiency state preparation, and a frequency-insensitive Raman coupling are developed to overcome the challenges from the half-integer spin and hyperfine interaction of atoms. A conjugated $\text{Ramsey-Bord}\stackrel{\ifmmode \acute{}\else \'{}\fi{}}{\mathrm{e}}$ interferometer with crossed Raman beams is realized with a coherence time longer than 2.3 ms. The four sets of interferometers developed using geometric relations greatly eliminate the error from the angle between Raman beams. The measured recoil frequency is ${\ensuremath{\omega}}_{r}=2\ensuremath{\pi}\ifmmode\times\else\texttimes\fi{}73\phantom{\rule{0.16em}{0ex}}672.789\phantom{\rule{0.16em}{0ex}}(36)$ Hz, representing the most precise measurement of the recoil frequency of 6Li^{6}\mathrm{Li}6Li by using the atom interferometer so far. The realized 6Li^{6}\mathrm{Li}6Li cold atom interferometer is not only an effective supplement to the existing interferometers, but also provides a good candidate in precision measurement owing to its low mass and high recoil frequency.