Optoelectronic oscillator stabilized to an intra-loop atomic filter with a coherent population trapping resonance

Sin Hyuk Yim, D. Cho

Published Jul 1, 2012• 3 citations
Publisher

Abstract

We report the construction and characterization of an optoelectronic oscillator stabilized to an intra-loop 85Rb cell with a 3.036-GHz coherent population trapping (CPT) resonance. We use an extended-cavity diode laser (ECDL) as a light source and directly modulate its injection current by using the beating signal filtered by the CPT resonance. Use of the ECDL guarantees stability of the carrier frequency and eliminates a bulky and power-consuming external modulator. We also adjust the cavity length and operate the ECDL in multimode in order to achieve a high modulation efficiency. To further improve the oscillator’s frequency stability, we incorporate a negative feedback system based on a CPT dispersion. The Allan deviation of the oscillator frequency is 3 × 10 −10 at a 100-s integration time.

DOI
10.3938/jkps.61.17

Related papers

Frequency pulling effect of an intraloop atomic filter in an optoelectronic oscillator

Dae Han Seo, Sin Hyuk Yim

The frequency pulling effect in an optoelectronic oscillator (OEO) due to the high dispersion produced by coherent population trapping (CPT) resonance in an intraloop Rb85 cell has been experimentally measured. With the direct modulation of the injection current of an extended-cavity diode laser, we construct the OEO and a beating signal with a frequency of 3.036 GHz is filtered by CPT resonance. The effective total loop length of the OEO under the CPT resonance condition can be significantly increased. As the optical path length of the OEO is changed, the microwave-frequency shift of the OEO corresponding to the effective total loop length is measured and reported.

Applied Optics•Jan 18, 2017•2 citations

Oscillator-free atomic clock using a multimode laser

Sin Hyuk Yim, D. Cho

We developed an atomic clock using two modes from a single extended-cavity diode laser in multimode operation. The two modes are phase locked with reference to a dispersion signal from a coherent population trapping (CPT) resonance of R85b at 3.036 GHz. The design is in principle free from an oscillator and a modulator and it is a significant simplification over a conventional CPT-based atomic clock. Allan deviation of the beat frequency is 1×10−10 at 200 s integration time.

Applied Physics Letters•May 24, 2010•7 citations

CPT chip-scale atomic clock with direct-modulation chip-external cavity diode laser

Jiqing Lian, Jie Miao, Tian Zhao +7 more

Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.

Applied Physics Letters•Jun 2, 2025•11 citations

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

Performance of a prototype atomic clock based on lin‖lin coherent population trapping resonances in Rb atomic vapor

Eugeniy E. Mikhailov, Travis Horrom, Nathan Belcher +1 more

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.

arXiv:0910.5881•Journal of the Optical Society of America B•Feb 3, 2010•55 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations
We report the construction and characterization of an optoelectronic oscillator stabilized to an intra-loop 85Rb cell with a 3.036-GHz coherent population trapping (CPT) resonance. We use an extended-cavity diode laser (ECDL) as a light source and directly modulate its injection current by using the beating signal filtered by the CPT resonance. Use of the ECDL guarantees stability of the carrier frequency and eliminates a bulky and power-consuming external modulator. We also adjust the cavity length and operate the ECDL in multimode in order to achieve a high modulation efficiency. To further improve the oscillator’s frequency stability, we incorporate a negative feedback system based on a CPT dispersion. The Allan deviation of the oscillator frequency is 3 × 10 −10 at a 100-s integration time.
The frequency pulling effect in an optoelectronic oscillator (OEO) due to the high dispersion produced by coherent population trapping (CPT) resonance in an intraloop Rb85 cell has been experimentally measured. With the direct modulation of the injection current of an extended-cavity diode laser, we construct the OEO and a beating signal with a frequency of 3.036 GHz is filtered by CPT resonance. The effective total loop length of the OEO under the CPT resonance condition can be significantly increased. As the optical path length of the OEO is changed, the microwave-frequency shift of the OEO corresponding to the effective total loop length is measured and reported.
Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.
Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.