Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Tunable Coherent Vacuum-Ultraviolet Generation in Atomic Vapors

R. T. Hodgson, P. P. Sorokin, James J. Wynne

Published Feb 18, 1974• 255 citations
Publisher

Abstract

Two tunable dye lasers have been used to generate coherent radiation at a tunable sum frequency in the vacuum-ultraviolet spectral region. Spectral ranges of \ensuremath{\sim}3500 ${\mathrm{cm}}^{\ensuremath{-}1}$ around 1895 \AA{} and \ensuremath{\sim}1200 ${\mathrm{cm}}^{\ensuremath{-}1}$ around 1798 \AA{} have been covered. These ranges may easily be extended. Large (\ensuremath{\sim}\ifmmode\times\else\texttimes\fi{}${10}^{4}$) enhancements of $2{\ensuremath{\nu}}_{1}+{\ensuremath{\nu}}_{2}$ sum mixing are seen when $2{\ensuremath{\nu}}_{1}$ is tuned to a double-quantum allowed transition from the ground state in Sr vapor.

DOI
10.1103/physrevlett.32.343

Related papers

Generation of continuously tunable coherent vacuum-ultraviolet radiation (140 to 106 nm) in zinc vapor

W. Jamroz, Paul E. LaRocque, Boris Peter Stoicheff

It is shown that resonantly enhanced, four-wave frequency mixing in Zn vapor provides coherent vacuum-ultraviolet radiation that is continuously tunable over the range 140.4 to 106.3 nm (or ~23000 cm(-1)).

Optics Letters•Dec 1, 1982•43 citations

Generation of high-brightness coherent radiation in the vacuum ultraviolet by four-wave parametric oscillation in mercury vapor

Jeffrey Bokor A, Richard R. Freeman, R. L. Panock +1 more

Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A frequency-doubled dye laser tuned to two-photon resonance with the 6s6d(1)D(2) level near 280.3 nm produced output at 184.9 and 143.5 nm. A tunable krypton fluoride excimer laser tuned to two-photon resonance with the 6s10s (1)S(0) level near 248.7 nm produced output at 140.1, 130.7, 130.1, 125.9, and 125.0 nm. Approximately 1-microJ, 200-W pulses were observed at 143.5 and 125.9 nm.

Optics Letters•Apr 1, 1981•60 citations

Generation of continuously tunable coherent vacuum-ultraviolet radiation in Cd vapor

Kenzo Miyazaki, Hirofumi Sakai, Takuzo Sato

Continuously tunable coherent vacuum-ultraviolet (VUV) radiation has been generated in the 128.7-135.3-nm region by two-photon resonant four-wave mixing in Cd vapor. The generated VUV has no spectral structure over the tuning range and indicates that Cd vapor is an efficient nonlinear medium for frequency conversion.

Optics Letters•Oct 1, 1984•14 citations

Generation of tunable coherent radiation below 1000 Å by four-wave mixing in krypton

Keith Bonin, Thomas J. Mcilrath

Coherent, narrow-band, tunable radiation in the extreme-ultraviolet spectral region was generated by a two-photon resonantly enhanced four-wave mixing process in krypton. Sum-generated radiation was produced near 942, 928, and 923 A with power efficiencies as high as 10−5. Difference-generated radiation near 1312 Å was also detected.

Journal of the Optical Society of America B•Apr 1, 1985•29 citations

Continuously Tunable Sum-Frequency Generation Involving Rydberg States

Robert W. Boyd, Daniel J. Gauthier, Jerzy S. Krasiński +1 more

It has recently been shown1 that extremely large values of the second-order nonlinear suceptibility can be obtained through use of Rydberg atomic states perturbed by an external electric field.2 In these experiments a value of χ(2) = 10-9 esu was obtained using a sodium vapor of number density ~1014 atoms cm-3 and a dc electric field of magnitude 1 kV/cm. One laser was tuned close to the sodium D2 resonance line while a second laser completed the two-photon resonance with a Rydberg state. A strong coherent UV beam at the sum frequency was generated in the forward direction. The splitting of the highly excited atomic levels induced by the external electric field created a broad region of overlapping levels, leading to continuous tunability. This technique can be applied to any system displaying a Rydberg series, and should be capable of producing coherent, tunable radiation in the extreme ultraviolet.

Topical Meeting on Laser Techniques in the Extreme Ultraviolet•Jan 1, 1984•0 citations

Generation of coherent tunable VUV radiation near the Ly-β transition of atomic hydrogen

John F. Reintjes

Third-harmonic conversion of light from a frequency-tuned XeCl laser is used to generate coherent vacuum-ultraviolet radiation that is tunable from 102.55 to 102.83 nm, a range that includes the Ly-β transition of atomic hydrogen at 102.57 nm. The use of this radiation for the detection of neutral hydrogen atoms by resonance fluorescence is discussed.

Optics Letters•Aug 1, 1980•22 citations
Two tunable dye lasers have been used to generate coherent radiation at a tunable sum frequency in the vacuum-ultraviolet spectral region. Spectral ranges of \ensuremath{\sim}3500 cm\ensuremath−1{\mathrm{cm}}^{\ensuremath{-}1}cm\ensuremath−1 around 1895 \AA{} and \ensuremath{\sim}1200 cm\ensuremath−1{\mathrm{cm}}^{\ensuremath{-}1}cm\ensuremath−1 around 1798 \AA{} have been covered. These ranges may easily be extended. Large (\ensuremath{\sim}\ifmmode\times\else\texttimes\fi{}104{10}^{4}104) enhancements of 2\ensuremathν1+\ensuremathν22{\ensuremath{\nu}}_{1}+{\ensuremath{\nu}}_{2}2\ensuremathν1​+\ensuremathν2​ sum mixing are seen when 2\ensuremathν12{\ensuremath{\nu}}_{1}2\ensuremathν1​ is tuned to a double-quantum allowed transition from the ground state in Sr vapor.
Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A frequency-doubled dye laser tuned to two-photon resonance with the 6s6d(1)D(2) level near 280.3 nm produced output at 184.9 and 143.5 nm. A tunable krypton fluoride excimer laser tuned to two-photon resonance with the 6s10s (1)S(0) level near 248.7 nm produced output at 140.1, 130.7, 130.1, 125.9, and 125.0 nm. Approximately 1-microJ, 200-W pulses were observed at 143.5 and 125.9 nm.
It has recently been shown1 that extremely large values of the second-order nonlinear suceptibility can be obtained through use of Rydberg atomic states perturbed by an external electric field.2 In these experiments a value of χ(2) = 10-9 esu was obtained using a sodium vapor of number density ~1014 atoms cm-3 and a dc electric field of magnitude 1 kV/cm. One laser was tuned close to the sodium D2 resonance line while a second laser completed the two-photon resonance with a Rydberg state. A strong coherent UV beam at the sum frequency was generated in the forward direction. The splitting of the highly excited atomic levels induced by the external electric field created a broad region of overlapping levels, leading to continuous tunability. This technique can be applied to any system displaying a Rydberg series, and should be capable of producing coherent, tunable radiation in the extreme ultraviolet.