Experimental results for the noise of photon-correlation and photon-structure functions are presented. The noise dependences on the mean count rate and on the sampling time are investigated by means of a specifically built linear fluctuation analyzer, and the results are compared with theoretical predictions. The predicted mean count rate dependence and sampling time dependence of the noise are confirmed by the experimental analysis. Some discrepancies between analytical expressions and experimental results are observed in the crossover predictions. The results show that the structure function has better noise performance for relatively high mean count rates and for long sampling times, which strongly suggests a wider use of this statistical estimator in measurements requiring good accuracy, as in the case of uniform sampling.
Experimental results for the noise of photon-correlation and photon-structure functions are presented. The noise dependences on the mean count rate and on the sampling time are investigated by means of a specifically built linear fluctuation analyzer, and the results are compared with theoretical predictions. The predicted mean count rate dependence and sampling time dependence of the noise are confirmed by the experimental analysis. Some discrepancies between analytical expressions and experimental results are observed in the crossover predictions. The results show that the structure function has better noise performance for relatively high mean count rates and for long sampling times, which strongly suggests a wider use of this statistical estimator in measurements requiring good accuracy, as in the case of uniform sampling.
A novel technique for photon correlation measurements, based on the excitation of a resonant system by photon-detector single pulses, analog/digital sampling, and deconvolution, has been developed and analyzed experimentally and by computer simulations. The measured correlation function is expressed by a convolution of the true photon correlation function of the optical field and a well-defined, noiseless resonator correlation function. The effect of detector statistics is reduced to the contribution of two integral parameters—the total single-pulse charge and the jitter of single-pulse centers. Good performance of this technique is demonstrated at high photon rates and resolutions, where the well-known photon-counting or single-quantum methods are ineffective. The novel technique offers linear recording of photocount time series without dead-time effects. The temporal resolution is defined by the sampling step of the analog/digital converter. The retrieval error does not exceed 1 to 3% at count rates higher than 1 GHz and single-pulse durations larger than the resolution cell. This technique can be effectively applied in photon correlation measurements of high dynamic optical fields.
An analysis of the variance of the structure function coefficients of a train of digital photodetections, both unnormalized and with various normalizations, is made and compared with known corresponding results for the photon correlation function. A gaussian-lorentzian model light field is used in both direct and homodyne detection. Numerical simulations confirm and extend the analytical results, which show certain circumstances when the structure function may be a useful alternative measure of spectral content.
An adequate analysis of photon correlation data requires knowledge about the statistical accuracy of the measured data. For the model of gamma-distributed intensities, that is including the effect of a finite intercept, the full covariance matrix is calculated for all the channels of the photon autocorrelation functions. A thorough discussion of multiple sample time correlation illuminates the importance of temporal averaging effects at large lag times. A practical estimation scheme is given for the noise in photon correlation data from a multiple sample time measurement.
Correlation between channels of the normalized photocount-rate correlation function g(2)(τ) becomes significant at high count rates and leads to a number of data-analysis problems. We derive an expression for channel correlation that is valid for a detector area of arbitrary extent and compare the theoretical predictions with measured values. A data-analysis procedure is demonstrated that employs the theoretical expression for channel correlation and provides a rigorous test of an assumed fitting function. The procedure facilitates the use of the cumulant method in determining the polydispersity of scatterers. An expression for the statistical bias of g(2)(τ) is also derived and compared with measured values.
Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel
High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.