Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors and Actuators A Physical

Towards a miniature atomic scalar magnetometer using a liquid crystal polarization rotator

J. Rutkowski, William Fourcault, F. Bertrand, Umberto Rossini, Stéphane Gétin, Stéphanie Le Calvez, Thomas Jäger, Étienne Herth, Christophe Gorecki, Matthieu Le Prado, Jean‐Michel Léger, Sophie Morales

Published May 13, 2014• 39 citations
Publisher
DOI
10.1016/j.sna.2014.05.003

Related papers

Miniature Absolute Scalar Magnetometer Based on the Rubidium Isotope 87Rb

H. Korth, Kim Strohbehn, Francisco J. Tejada +3 more

LPICo•Oct 1, 2012•0 citations

Miniature Dual-Mode Absolute Scalar Magnetometer Based on the Rubidium Isotope 87Rb

H. Korth, Kim Strohbehn, John E. Kitching

LPICo•Oct 1, 2016•0 citations

Four-channel miniaturized SERF magnetometer with spatial inhomogeneous atomic polarization

Zihua Liang, Yuhao Zhang, Tengyue Long +7 more

Optics & Laser Technology•Nov 4, 2024•15 citations

Ultra‐compact and high‐precision differential detection method based on liquid crystal polarization grating for miniature atomic magnetometer

Zhibo Cui, Yuhao Wang, Ying Liu +5 more

Abstract Atomic magnetometers (AMs) that use alkali vapors, such as rubidium, are among the most sensitive sensors for magnetic field measurement. They commonly use polarization differential detection to mitigate common‐mode noise. Nevertheless, traditional differential detection optics, including polarization beam splitters (PBS) and half‐wave plates, are typically bulky and large, which restricts further reductions in sensor dimensions. In this study, a combination of liquid crystal polarization grating (LCPG) and liquid crystal quarter‐wave plate is used for differential detection in AMs, with magnetic field strength determined by measuring the intensity of two diffracted beams from the LCPG. The experimental findings indicate that the fabricated LCPG exhibits a circularly polarized extinction ratio of 3,656 and achieves an average diffraction efficiency of 99 %. In addition, the differential detection method based on LCPG can achieve an angular resolution of 1.48 × 10 −7 rad. Subsequently, the method is employed in an AM to achieve an average magnetic sensitivity of 13.8 fT/Hz 1/2 . Compared to the PBS‐based differential detection method, this method enhances the magnetometer response coefficient by 13 % and achieves co‐side distribution of the two diffracted beams, thereby avoiding the need for additional vertical optical paths. The effective thickness of the detection optics is reduced to the micrometer scale, allowing for future integration as thin films onto microfabricated vapor cells. This study offers a practical solution for miniaturized AMs with exceptionally high sensitivity.

Nanophotonics•Oct 3, 2024•14 citations

Towards a compact accurate vector-scalar atomic magnetometer

Juniper W. Pollock, Svenja A. Knappe

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Development of a compact atomic co-magnetometer

Georgios Vasilakis, Thomas W. Kornack, R. Ghosh +2 more

Bulletin of the American Physical Society•May 19, 2006•0 citations
Abstract Atomic magnetometers (AMs) that use alkali vapors, such as rubidium, are among the most sensitive sensors for magnetic field measurement. They commonly use polarization differential detection to mitigate common‐mode noise. Nevertheless, traditional differential detection optics, including polarization beam splitters (PBS) and half‐wave plates, are typically bulky and large, which restricts further reductions in sensor dimensions. In this study, a combination of liquid crystal polarization grating (LCPG) and liquid crystal quarter‐wave plate is used for differential detection in AMs, with magnetic field strength determined by measuring the intensity of two diffracted beams from the LCPG. The experimental findings indicate that the fabricated LCPG exhibits a circularly polarized extinction ratio of 3,656 and achieves an average diffraction efficiency of 99 %. In addition, the differential detection method based on LCPG can achieve an angular resolution of 1.48 × 10 −7 rad. Subsequently, the method is employed in an AM to achieve an average magnetic sensitivity of 13.8 fT/Hz 1/2 . Compared to the PBS‐based differential detection method, this method enhances the magnetometer response coefficient by 13 % and achieves co‐side distribution of the two diffracted beams, thereby avoiding the need for additional vertical optical paths. The effective thickness of the detection optics is reduced to the micrometer scale, allowing for future integration as thin films onto microfabricated vapor cells. This study offers a practical solution for miniaturized AMs with exceptionally high sensitivity.