Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Quantum-noise reduction at frequencies up to 0.5 GHz using pulsed parametric amplification

Paul D. Townsend, R. Loudon

Published Jan 1, 1992• 34 citations
Publisher

Abstract

Measurements of quantum-noise reduction have been performed over a broad frequency range up to 0.5 GHz using pulses of squeezed light generated by parametric amplification in ${\mathrm{KTiOPO}}_{4}$ crystals. Both balanced-homodyne and direct-difference photodetection schemes were employed, and 0.5 dB of noise reduction was routinely obtained. A continuous-mode traveling-wave theory including the effects of dispersion and loss has been employed to model the experimental results.

DOI
10.1103/physreva.45.458

Related papers

Pulsed Squeezed Light

Richard E. Slusher, Philippe Grangier, Arthur LaPorta +2 more

Squeezed light in the form of a train of pulses, each approximately 100 ps in width, has been generated by parametric down-conversion in KTiOP${\mathrm{O}}_{4}$ crystals. The measured noise reduction in the quiet quadrature of the field is 0.6 dB below the shot-noise limit. The quadrature noise components are measured with a balanced homodyne detector using a pulse train for the local oscillator. The noise reduction extends over a broad spectrum and has important implications for precision measurement at very short time scales.

Physical Review Letters•Nov 30, 1987•283 citations

Quantum-noise reduction with a Q-switched laser

Orhan Aytür, Prem Kumar

Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

High-bandwidth squeezed light at 1550 nm from a compact monolithic PPKTP cavity

Stefan Ast, Moritz Mehmet, Roman Schnabel

We report the generation of squeezed vacuum states of light at 1550 nm with a broadband quantum noise reduction of up to 4.8 dB ranging from 5 MHz to 1.2 GHz sideband frequency. We used a custom-designed 2.6 mm long biconvex periodically-poled potassium titanyl phosphate (PPKTP) crystal. It featured reflectively coated end surfaces, 2.26 GHz of linewidth and generated the squeezing via optical parametric amplification. Two homodyne detectors with different quantum efficiencies and bandwidths were used to characterize the non-classical noise suppression. We measured squeezing values of up to 4.8 dB from 5 to 100 MHz and up to 3 dB from 100 MHz to 1.2 GHz. The squeezed vacuum measurements were limited by detection loss. We propose an improved detection scheme to measure up to 10 dB squeezing over 1 GHz. Our results of GHz bandwidth squeezed light generation provide new prospects for high-speed quantum key distribution.

arXiv:1303.1925•Optics Express•May 30, 2013•97 citations

3 dB squeezing by single-pass parametric amplification in a periodically poled KTiOPO_4 crystal

Takuya Hirano, K. Kotani, T. Ishibashi +2 more

We present the experimental observation of pulsed squeezed light from a degenerate optical parametric amplifier pumped by a second harmonic of a continuous-wave mode-locked Nd:YVO4 laser. With a single pass through a 10 mm long periodically poled KTiOPO4 crystal, the classical parametric gain of 11 is observed. The measured noise reduction in the quiet quadrature is 3.2 dB below the shot-noise level.

Optics Letters•Jul 1, 2005•29 citations

Atomic spectroscopy with squeezed light

Harry J. Kimble, Eugene Simon Polzik, J. Carri

A frequency tunable source of squeezed light has been developed for application to a variety of problems in atomic physics. The basic experimental arrangement consists of a subthreshold optical parametric oscillator (OPO) that is pumped by the frequency-doubled output of a titanium-sapphire laser. Squeezed light with continuous tunability of 2 GHz has been generated with a directly observed nonclassical noise reduction of 5.0 dB relative to the vacuumstate limit in a balanced homodyne detector (5.2 dB when corrected for detector noise). Although our source is potentially broadly tunable over the noncritical phase-matching bandwidth of potassium niobate, current research has concentrated on operation at 852 nm for excitation of the D2 line of atomic cesium. Relative to the usual quantum limit associated with vacuumstate fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in FM saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB after correction for detector noise.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Pulsed homodyne measurements of femtosecond squeezed pulses generated by single-pass parametric deamplification

Jérôme Wenger, Rosa Tualle-Brouri, Philippe Grangier

A new scheme is described for the generation of pulsed squeezed light by use of femtosecond pulses that have been parametrically deamplified through a single pass in a thin (100-microm) potassium niobate crystal with a significant deamplification of approximately -3 dB. The quantum noise of each pulse is registered in the time domain by single-shot homodyne detection operated with femtosecond pulses; the best squeezed quadrature variance was 1.87 dB below the shot-noise level. Such a scheme provides a basic resource for time-resolved quantum communication protocols.

arXiv:quant-ph/0402193•Optics Letters•Jun 1, 2004•66 citations
Measurements of quantum-noise reduction have been performed over a broad frequency range up to 0.5 GHz using pulses of squeezed light generated by parametric amplification in KTiOPO4{\mathrm{KTiOPO}}_{4}KTiOPO4​ crystals. Both balanced-homodyne and direct-difference photodetection schemes were employed, and 0.5 dB of noise reduction was routinely obtained. A continuous-mode traveling-wave theory including the effects of dispersion and loss has been employed to model the experimental results.
Squeezed light in the form of a train of pulses, each approximately 100 ps in width, has been generated by parametric down-conversion in KTiOPO4{\mathrm{O}}_{4}O4​ crystals. The measured noise reduction in the quiet quadrature of the field is 0.6 dB below the shot-noise limit. The quadrature noise components are measured with a balanced homodyne detector using a pulse train for the local oscillator. The noise reduction extends over a broad spectrum and has important implications for precision measurement at very short time scales.
Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.
We report the generation of squeezed vacuum states of light at 1550 nm with a broadband quantum noise reduction of up to 4.8 dB ranging from 5 MHz to 1.2 GHz sideband frequency. We used a custom-designed 2.6 mm long biconvex periodically-poled potassium titanyl phosphate (PPKTP) crystal. It featured reflectively coated end surfaces, 2.26 GHz of linewidth and generated the squeezing via optical parametric amplification. Two homodyne detectors with different quantum efficiencies and bandwidths were used to characterize the non-classical noise suppression. We measured squeezing values of up to 4.8 dB from 5 to 100 MHz and up to 3 dB from 100 MHz to 1.2 GHz. The squeezed vacuum measurements were limited by detection loss. We propose an improved detection scheme to measure up to 10 dB squeezing over 1 GHz. Our results of GHz bandwidth squeezed light generation provide new prospects for high-speed quantum key distribution.
A frequency tunable source of squeezed light has been developed for application to a variety of problems in atomic physics. The basic experimental arrangement consists of a subthreshold optical parametric oscillator (OPO) that is pumped by the frequency-doubled output of a titanium-sapphire laser. Squeezed light with continuous tunability of 2 GHz has been generated with a directly observed nonclassical noise reduction of 5.0 dB relative to the vacuumstate limit in a balanced homodyne detector (5.2 dB when corrected for detector noise). Although our source is potentially broadly tunable over the noncritical phase-matching bandwidth of potassium niobate, current research has concentrated on operation at 852 nm for excitation of the D2 line of atomic cesium. Relative to the usual quantum limit associated with vacuumstate fluctuations, enhanced sensitivity is demonstrated for the detection of Doppler-free resonances in FM saturation spectroscopy, with an improvement of 3.1 dB directly observed and 3.8 dB after correction for detector noise.
A new scheme is described for the generation of pulsed squeezed light by use of femtosecond pulses that have been parametrically deamplified through a single pass in a thin (100-microm) potassium niobate crystal with a significant deamplification of approximately -3 dB. The quantum noise of each pulse is registered in the time domain by single-shot homodyne detection operated with femtosecond pulses; the best squeezed quadrature variance was 1.87 dB below the shot-noise level. Such a scheme provides a basic resource for time-resolved quantum communication protocols.