Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Correlated imaging with shaped spatially partially coherent light

Erwan Baleine, Aristide C. Dogariu, G. S. Agarwal

Published Jun 22, 2006• 28 citations
Publisher

Abstract

Using a classical source generating a field with an adjustable degree of spatial coherence, we propose and demonstrate a two-photon correlated Fourier imaging scheme in which both amplitude and phase information about the spatial frequencies of an object can be obtained. The effects of the incident field's partial coherence are discussed in a geometrical optics approach.

DOI
10.1364/ol.31.002124

Related papers

Geometrical optics in correlated imaging systems

De-Zhong Cao, Jun Xiong, Kaige Wang

We discuss the geometrical optics of correlated imaging for two kinds of spatial correlations corresponding, respectively, to a classical thermal light source and a quantum two-photon entangled source. Due to the different features in the second-order spatial correlation, the two sources obey different imaging equations. The quantum entangled source behaves as a mirror, whereas the classical thermal source looks like a phase-conjugate mirror in the correlated imaging.

arXiv:quant-ph/0407065•Physical Review A•Jan 3, 2005•239 citations

Phase and amplitude imaging with quantum correlations through Fourier Ptychography

Tomas Aidukas, Pavan Chandra Konda, Andrew Robert Harvey +2 more

Extracting as much information as possible about an object when probing with a limited number of photons is an important goal with applications from biology and security to metrology. Imaging with a few photons is a challenging task as the detector noise and stray light are then predominant, which precludes the use of conventional imaging methods. Quantum correlations between photon pairs has been exploited in a so called 'heralded imaging scheme' to eliminate this problem. However these implementations have so-far been limited to intensity imaging and the crucial phase information is lost in these methods. In this work, we propose a novel quantum-correlation enabled Fourier Ptychography technique, to capture high-resolution amplitude and phase images with a few photons. This is enabled by the heralding of single photons combined with Fourier ptychographic reconstruction. We provide experimental validation and discuss the advantages of our technique that include the possibility of reaching a higher signal to noise ratio and non-scanning Fourier Ptychographic acquisition.

arXiv:1906.06569•Scientific Reports•Jul 18, 2019•32 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations

Two-Photon Spatial Multiplexing: Image Encoding in Gaussian Noncircularity of Light

Wanting Hou, Zhiyuan Ye, Hongchao Liu +2 more

The search for new degrees of freedom (DoF) of light is central to advancing optical information encoding and multiplexing. Gaussian statistics are ubiquitous in nature, and here we unlock an unexpected statistical DoF in the joint noncircularity of Gaussian light. For a pair of Gaussian light fields, the covariance- and pseudocovariance-dominated two types of correlations dictate the propagation rules and the image-encoding responses, mapping optical information into coordinate-difference and coordinate-sum momentum spaces, respectively. A hybrid random-phase grating array enables the experimental preparation of noncircular Gaussian light with programmable coexistence, yielding X-shaped intensity correlations while subtly reducing the degree of second-order coherence. Two independently programmed images coexist in the same beams at identical wavelength and polarization, yet are selectively decoded through two-photon correlation geometry without physical filters. Remarkably, both images remain recoverable even when structured stray light is as intense as the signal. These results unlock a hidden statistical dimension of optical information encoding, transforming Gaussian fluctuations into a dual-channel information carrier and joint noncircularity into a programmable optical DoF.

arXiv:2610.19554•Oct 14, 2026•0 citations

Odd-order aberration cancellation in correlated-photon imaging

David S. Simon, Alexander V. Sergienko

We discuss a correlated two-photon imaging apparatus that is capable of producing images that are free of the effects of odd-order aberration introduced by the optical system. We show that both quantum-entangled and classically correlated light sources are capable of producing the desired spatial-aberration cancellation.

arXiv:1008.0801•Physical Review A•Aug 27, 2010•16 citations

Correlated Imaging with Aberration Cancellation

David S. Simon, Alexander V. Sergienko

We discuss an apparatus capable of producing correlated-photon “ghost” images that cancel all object-induced aberrations in a particular plane and all odd-order aberrations induced by the image-forming optics. We show that both entangled and classically correlated light sources can produce the desired spatial-aberration cancellation.

International Conference on Quantum Information•Jan 1, 2011•0 citations
Using a classical source generating a field with an adjustable degree of spatial coherence, we propose and demonstrate a two-photon correlated Fourier imaging scheme in which both amplitude and phase information about the spatial frequencies of an object can be obtained. The effects of the incident field's partial coherence are discussed in a geometrical optics approach.
Extracting as much information as possible about an object when probing with a limited number of photons is an important goal with applications from biology and security to metrology. Imaging with a few photons is a challenging task as the detector noise and stray light are then predominant, which precludes the use of conventional imaging methods. Quantum correlations between photon pairs has been exploited in a so called 'heralded imaging scheme' to eliminate this problem. However these implementations have so-far been limited to intensity imaging and the crucial phase information is lost in these methods. In this work, we propose a novel quantum-correlation enabled Fourier Ptychography technique, to capture high-resolution amplitude and phase images with a few photons. This is enabled by the heralding of single photons combined with Fourier ptychographic reconstruction. We provide experimental validation and discuss the advantages of our technique that include the possibility of reaching a higher signal to noise ratio and non-scanning Fourier Ptychographic acquisition.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
The search for new degrees of freedom (DoF) of light is central to advancing optical information encoding and multiplexing. Gaussian statistics are ubiquitous in nature, and here we unlock an unexpected statistical DoF in the joint noncircularity of Gaussian light. For a pair of Gaussian light fields, the covariance- and pseudocovariance-dominated two types of correlations dictate the propagation rules and the image-encoding responses, mapping optical information into coordinate-difference and coordinate-sum momentum spaces, respectively. A hybrid random-phase grating array enables the experimental preparation of noncircular Gaussian light with programmable coexistence, yielding X-shaped intensity correlations while subtly reducing the degree of second-order coherence. Two independently programmed images coexist in the same beams at identical wavelength and polarization, yet are selectively decoded through two-photon correlation geometry without physical filters. Remarkably, both images remain recoverable even when structured stray light is as intense as the signal. These results unlock a hidden statistical dimension of optical information encoding, transforming Gaussian fluctuations into a dual-channel information carrier and joint noncircularity into a programmable optical DoF.