Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Appropriate Gate Time for Single Molecular Photon Detection Based on Optimal Signal-to-Noise Ratio Analyses

Shuangli Dong, Huang Tao, Liu Yuan, Jun Wang, Liantuan Xiao, Jia Suo-Tang

Published May 1, 2007• 1 citation
Publisher

Abstract

Signal-to-noise ratio of fluorescence detection from a single molecule is analysed by using time-gated techniques. It is found that the optimal signal-to-noise ratio can be obtained by choosing an appropriate gate time with a certain optical background. The dependences of molecular fluorescence lifetime and the optimal signal-to-noise ratio on the appropriate gate time are respectively discussed with two kinds of background sources, chaotic state with uniform distribution and coherent state with exponential distribution in time domain. For chaotic state background we find that a certain range for appropriate gate time can be obtained with a definite fluorescence lifetime, larger fluorescence lifetime would lower the value of optimal signal-to-noise ratios. For coherent state background we find that there is also a narrow range of appropriate gate time when lifetime of single molecule is less than that of background photons.

DOI
10.1088/0256-307x/24/5/027

Related papers

Signal-background-ratio dependence of single molecular photon sources

Xiao Lian

This paper presents the theoretical research on the synchronization sample gate time determination considering the optimal signal-to-noise(SNR) via differentsignal-to-background(SBR) where the background shows time-uniformity distribution or time-exponential distribution.Based on Hanbury-Brown-Twiss (HBT) method,the photon statistics P(n,n=0、1、2) are analyzed by recording of every incident from the single photon source.When P(1)2P(2)-3P(2),an efficient method to determine the SBR of triggered single photons source,which shows SBR=2/2P(2),is carried out.Additionally,we have obtained an efficient method to distinguish single molecular by the double-photon statistics probability P(2),which shows P(2)(2-4-2An-G)2/2,when SBR2.4.

Journal of Atomic and Molecular Physics•Jan 1, 2007•0 citations

Cascaded Optical Kerr Gate for Fluorescence Measurement With High Signal-to-Noise Ratio

Zhenqiang Huang, Zhen Kang, Wenjiang Tan +2 more

Traditional optical Kerr gates (OKG) often suffer from leakage fluorescence background when sampling and measuring fluorescence spectra due to the limited extinction of the polarizers used in optical Kerr gates. In this letter, we propose a cascaded optical Kerr gate (COKG) for measuring fluorescence spectroscopy with a high signal-to-noise ratio by suppressing this leakage fluorescence background. Our proposed COKG consists of an optical Kerr gate with a fast-switching time at the front stage and an optical Kerr gate with a high transmission at the back stage. The experimental results show that the signal-to-noise ratio for the COKG can be improved by about two orders of magnitude compared to the single OKG.

IEEE Photonics Technology Letters•Nov 23, 2023•1 citation

Effect of Background Noise on the Photon Statistics of Triggered Single Molecules

Liantuan Xiao, Yanting Zhao, Huang Tao +3 more

We theoretically derive exact expressions for Mandel's Q parameter of the triggered single molecular source, which is inferred from the probabilities P RS ( n ) using the record of each photon detection event based on Hanbury Brown and Twiss detection. The real triggered source is recognized as an ideal single photon source with a Poissonian statistics background. How to decrease the background and to increase the efficiency are discussed. It is established that the sub-Poissonian statistics formation can be determined by comparing the measured Q RS of the real single triggered molecular with Q C of the Poissonian source containing the same mean photons. By this method, we also give an efficient way to measure signal-to-background ratios of triggered single photons.

Chinese Physics Letters•Feb 19, 2004•7 citations

Development of time-resolved fluorescence spectroscopy using heralded emission spectroscopy for organic light-emitting materials

Nicola J. Fairbairn, Koya Onoda, Ozora Iso +7 more

Organic light-emitting materials are widely used in optoelectronics and bioimaging, but sometimes conventional fluorescence spectroscopy techniques can be limited by scattering, background fluorescence, photon pile-up and photobleaching. We report a quantum-spectroscopic approach using frequency-entangled, nondegenerate photon pairs generated via spontaneous parametric down-conversion with heralded detection, to perform photoluminescence lifetime measurements at low excitation intensities. We demonstrate this approach across three organic light-emitting material classes: the fluorescent dye Rhodamine 6G, an organic semiconducting conjugated polymer poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), and a fluorescent protein mOrange. The intrinsic timing correlation between signal and idler photons enables coincidence gating that suppresses uncorrelated background counts. Across all materials and integration times of 500, 1000 and 3600 seconds, heralded detection yields signal-to-noise ratios 1.6-3.0 times higher than classical pulsed-laser excitation attenuated to match heralded photon counts in the fitting range. For MEH-PPV, this roughly halves the noise amplitude. Our measured lifetimes closely match long-integration classical pulsed-laser reference values.

arXiv:2611.07770•Nov 5, 2026•0 citations

Statistical sensitivity of phase measurements via laser-induced fluorescence with optical cycling detection

Zack Lasner, David P. DeMille

In atomic and molecular phase measurements using laser-induced fluorescence detection, optical cycling can enhance the effective photon detection efficiency and hence improve sensitivity. We show that detecting many photons per atom or molecule, while necessary, is not a sufficient condition to approach the quantum projection limit for detection of the phase in a two-level system. In particular, detecting the maximum number of photons from an imperfectly closed optical cycle reduces the signal-to-noise ratio (SNR) by a factor of $\sqrt{2}$, compared to the ideal case in which leakage from the optical cycle is sufficiently small. We derive a general result for the SNR in a system in terms of the photon detection efficiency, probability for leakage out of the optical cycle per scattered photon, and the product of the average photon scattering rate and total scattering time per atom or molecule.

arXiv:1809.00014•Physical Review A•Nov 14, 2018•17 citations

Determination of signal-to-background ratio of single molecular photon source based on photon counting statistics

Xiao-Bo Wang, Huang Tao, Shao Jun-Hu +4 more

The real triggered single molecule source is recognized as an ideal single photon source with a Poissonian statistics background. By considering the effect of the triplet state in single molecule energy level, an explicit function is given for the signaltobackgound ratio(SBR) by use of photoncounting statistics. When PRS(1)2PRS(2)-3PRS(2), we present an effici ent method to determine the SBR of the triggered single photons source, which s hows SBR=P2RS(1)/2PRS(2).In addition, the expression of Q, as a function of signaltobackgound ratio, has been obtained. It turns o ut that this method is simpler and gives a greater accuracy than previous proce dures.

Acta Physica Sinica•Jan 1, 2005•0 citations
Signal-to-noise ratio of fluorescence detection from a single molecule is analysed by using time-gated techniques. It is found that the optimal signal-to-noise ratio can be obtained by choosing an appropriate gate time with a certain optical background. The dependences of molecular fluorescence lifetime and the optimal signal-to-noise ratio on the appropriate gate time are respectively discussed with two kinds of background sources, chaotic state with uniform distribution and coherent state with exponential distribution in time domain. For chaotic state background we find that a certain range for appropriate gate time can be obtained with a definite fluorescence lifetime, larger fluorescence lifetime would lower the value of optimal signal-to-noise ratios. For coherent state background we find that there is also a narrow range of appropriate gate time when lifetime of single molecule is less than that of background photons.
This paper presents the theoretical research on the synchronization sample gate time determination considering the optimal signal-to-noise(SNR) via differentsignal-to-background(SBR) where the background shows time-uniformity distribution or time-exponential distribution.Based on Hanbury-Brown-Twiss (HBT) method,the photon statistics P(n,n=0、1、2) are analyzed by recording of every incident from the single photon source.When P(1)2P(2)-3P(2),an efficient method to determine the SBR of triggered single photons source,which shows SBR=2/2P(2),is carried out.Additionally,we have obtained an efficient method to distinguish single molecular by the double-photon statistics probability P(2),which shows P(2)(2-4-2An-G)2/2,when SBR2.4.
Traditional optical Kerr gates (OKG) often suffer from leakage fluorescence background when sampling and measuring fluorescence spectra due to the limited extinction of the polarizers used in optical Kerr gates. In this letter, we propose a cascaded optical Kerr gate (COKG) for measuring fluorescence spectroscopy with a high signal-to-noise ratio by suppressing this leakage fluorescence background. Our proposed COKG consists of an optical Kerr gate with a fast-switching time at the front stage and an optical Kerr gate with a high transmission at the back stage. The experimental results show that the signal-to-noise ratio for the COKG can be improved by about two orders of magnitude compared to the single OKG.
We theoretically derive exact expressions for Mandel's Q parameter of the triggered single molecular source, which is inferred from the probabilities P RS ( n ) using the record of each photon detection event based on Hanbury Brown and Twiss detection. The real triggered source is recognized as an ideal single photon source with a Poissonian statistics background. How to decrease the background and to increase the efficiency are discussed. It is established that the sub-Poissonian statistics formation can be determined by comparing the measured Q RS of the real single triggered molecular with Q C of the Poissonian source containing the same mean photons. By this method, we also give an efficient way to measure signal-to-background ratios of triggered single photons.
Organic light-emitting materials are widely used in optoelectronics and bioimaging, but sometimes conventional fluorescence spectroscopy techniques can be limited by scattering, background fluorescence, photon pile-up and photobleaching. We report a quantum-spectroscopic approach using frequency-entangled, nondegenerate photon pairs generated via spontaneous parametric down-conversion with heralded detection, to perform photoluminescence lifetime measurements at low excitation intensities. We demonstrate this approach across three organic light-emitting material classes: the fluorescent dye Rhodamine 6G, an organic semiconducting conjugated polymer poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), and a fluorescent protein mOrange. The intrinsic timing correlation between signal and idler photons enables coincidence gating that suppresses uncorrelated background counts. Across all materials and integration times of 500, 1000 and 3600 seconds, heralded detection yields signal-to-noise ratios 1.6-3.0 times higher than classical pulsed-laser excitation attenuated to match heralded photon counts in the fitting range. For MEH-PPV, this roughly halves the noise amplitude. Our measured lifetimes closely match long-integration classical pulsed-laser reference values.
In atomic and molecular phase measurements using laser-induced fluorescence detection, optical cycling can enhance the effective photon detection efficiency and hence improve sensitivity. We show that detecting many photons per atom or molecule, while necessary, is not a sufficient condition to approach the quantum projection limit for detection of the phase in a two-level system. In particular, detecting the maximum number of photons from an imperfectly closed optical cycle reduces the signal-to-noise ratio (SNR) by a factor of 2\sqrt{2}2​, compared to the ideal case in which leakage from the optical cycle is sufficiently small. We derive a general result for the SNR in a system in terms of the photon detection efficiency, probability for leakage out of the optical cycle per scattered photon, and the product of the average photon scattering rate and total scattering time per atom or molecule.
The real triggered single molecule source is recognized as an ideal single photon source with a Poissonian statistics background. By considering the effect of the triplet state in single molecule energy level, an explicit function is given for the signaltobackgound ratio(SBR) by use of photoncounting statistics. When PRS(1)2PRS(2)-3PRS(2), we present an effici ent method to determine the SBR of the triggered single photons source, which s hows SBR=P2RS(1)/2PRS(2).In addition, the expression of Q, as a function of signaltobackgound ratio, has been obtained. It turns o ut that this method is simpler and gives a greater accuracy than previous proce dures.