Annalen der Physik

Nonlinear dynamics in a high-gain amplifier: the dc SQUID

Adi R. Bulsara, Kurt A. Wiesenfeld, Mario E. Inchiosa

Published Sep 25, 2000• 5 citations
Publisher

Abstract

Abstract We study the detection of very weak time‐periodic magnetic signals via a double‐junction (dc) Superconducting Quantum Interference Device (SQUID). The device, represented by two coupled nonlinear differential equations for the quantum mechanical junction phase differences, admits long‐time static or oscillatory solutions, the transition between them being easily controlled by experimentally accessible parameters. Gain is maximal when the device is tuned to the onset of the oscillatory solutions; i.e., when the minima in the 2D potential function disappear. We concentrate on the SQUID dynamics near this critical point and compute the oscillation frequency via a center manifold reduction of the full 2D dynamics. Knowing this frequency permits its exploitation as a detection/classification tool in magnetic remote sensing applications.

DOI
10.1002/andp.200051209-1003

Related papers

Noise-mediated cooperative behavior and signal detection in dc SQUIDs

Mario E. Inchiosa

We study the detection of very weak time-periodic magnetic signals via a double-junction (dc) Superconducting Quantum Interference Device (SQUID). The device, represented by two coupled nonlinear differential equations for the quantum mechanical junction phases, admits of long-time static or oscillatory solutions, the transition being controllable by experimental parameters. Signal detection is optimal when the device is “tuned” to the onset of the oscillatory solutions; i.e., when the minima in the 2D potential function disappear. Modeling the device via a derived input-output transfer characteristic yields a response (quantified via the signal-to-noise ratio at the signal frequency) in good agreement with recent experiments. We also present some preliminary results pertaining to coupled dc SQUIDs, taking into account the (incoherent) thermal noise sources in each of the Josephson junctions. As might be expected from previous work, coupling the SQUIDs and/or summing their outputs enhances the response to the external signal.

AIP conference proceedings•Jan 1, 2000•2 citations

Proposal for a Beat Oscillating Superconducting Quantum Interference Device

Hisao Furukawa, Shinji Tomiyama, Itsuo Hatono +1 more

We describe a new dc-superconducting quantum interference device (SQUID) circuit of the FM type, which has a large coefficient for converting an applied magnetic flux into a frequency of MHz band or a lower band. The circuit consists of a SQUID amplifier composed of two stages, formed by a superconducting weak link and two dc-SQUID elements with nonhysteretic characteristics. In the first stage, the weak link and dc-SQUID elements are connected in parallel and operated by a common bias voltage. Since the respective elements oscillate with high frequencies by the ac Josephson effect, the two frequencies interact with each other, so that, the first stage generates a beat signal of a lower frequency. In the second stage, the other dc-SQUID element with a intrinsic flux gain enhances the beat signal generated during the first stage. A theoretical analysis of the circuit with computer simulation shows that the beat frequency is a periodical function of the magnetic flux, and the SQUID amplifier with two stages can improve the flux sensitivity.

Japanese Journal of Applied Physics•May 1, 1998•0 citations

Tunable strong nonlinearity of a micromechanical beam embedded in a dc-superconducting quantum interference device

Lior Ella, D. Yuvaraj, Oren Suchoi +2 more

We present a study of the controllable nonlinear dynamics of a micromechanical beam coupled to a dc-SQUID (superconducting quantum interference device). The coupling between these systems places the modes of the beam in a highly nonlinear potential, whose shape can be altered by varying the bias current and applied flux of the SQUID. We detect the position of the beam by placing it in an optical cavity, which sets free the SQUID to be used solely for actuation. This enables us to probe the previously unexplored full parameter space of this device. We measure the frequency response of the beam and find that it displays a Duffing oscillator behavior which is periodic in the applied magnetic flux. To account for this, we develop a model based on the standard theory for SQUID dynamics. In addition, with the aim of understanding if the device can reach nonlinearity at the single phonon level, we use this model to show that the responsivity of the current circulating in the SQUID to the position of the beam can become divergent, with its magnitude limited only by noise. This suggests a direction for the generation of macroscopically distinguishable superposition states of the beam.

arXiv:1312.1247•Journal of Applied Physics•Jan 6, 2015•4 citations

Radio frequency pumped superconducting quantum interference devices with two quantization loops

G.S. Krivoy, H. Koch

Conventional rf SQUIDs (superconducting quantum interference devices) consist of a superconducting loop interrupted by one weak link, and when read out via a tank circuit they produce output signals in the order of a few tens of microvolts. When the single weak link is replaced by a dc SQUID (a superconducting loop with two junctions) a so-called double quantization loop SQUID is formed. In this paper it is shown theoretically, and supported experimentally with thin-film devices of three different designs, that the general behaviour can be explained by a simplified picture of the fixed critical current of the single junction of the rf SQUID being replaced by an effective critical current of a dc SQUID loop that is varied by the applied magnetic flux (i.e., we have a rf SQUID with a variable β parameter). A more detailed analysis of the experimental data and the theory of this novel device reveals its interesting nonlinear character and shows the deviations from this simple picture. It is demonstrated experimentally that output signals in the order of ≥1 mV can be obtained with a suitable read-out mode for the tank circuit, a clear advantage when compared to conventional rf SQUIDs. With respect to dc SQUIDs, the coupling to integrated planar input coils will be unproblematic since no microwave resonances should occur in the structures.

Journal of Applied Physics•Aug 15, 1993•16 citations

Current amplification with asymmetric direct current superconducting quantum interference devices at 77 K

R. Kleiner, D. Koelle, Frank Ludwig +3 more

One can use a direct current (dc) superconducting quantum interference device (SQUID) as a current amplifier by injecting a signal current Is into part of the superconducting loop and detecting the resultant change in critical current Ic. The current gain max ‖dIc/dIs‖ can be increased by making the inductances of the two arms of the SQUID asymmetric, thereby skewing the transfer function Ic vs Is. Detailed simulations of the device performance include an analysis of the impact of inductance and junction asymmetry on the transfer function. At 77 K a maximum current gain of 5 should be achievable albeit for frequencies below 1 GHz. An increase in the operating speed to 2 GHz can be achieved by reducing the gain to 2. We have fabricated asymmetric YBa2Cu3O7−x dc SQUIDs on SrTiO3 bicrystal substrates and operated them at 77 K. Using a second, readout SQUID to monitor changes in the critical current, we have achieved a low-frequency current gain up to 2.3. By coupling two SQUIDs together, we have increased the gain to 8.5.

Journal of Applied Physics•Jan 15, 1996•9 citations

Weak Radio Frequency Signal Reception Sensitivity Based on DC Superconducting Quantum Interference Devices

Shanchi Wu, Chen Gong, Shangbin Li +2 more

Superconducting quantum interference devices (SQUIDs) are promising for detection of extremely weak power regimes for the Internet of Things and long-distance satellite networks. In low-frequency magnetic signal measurements, it has demonstrated superior performance over the traditional systems. We review the resistively and capacitively shunted junction model of dc SQUIDs and investigate its transfer function to magnetic flux signals while taking thermal fluctuation into account. We numerically evaluate the influence of bias current and bias flux signal to determine the operating parameters of the device. The performances related to SQUID ring inductance operating at 4.2 K and 77 K are demonstrated. Combined with common radio frequency front-end modules, including low-noise amplifier and low-pass filter, we evaluate the bit-error-rate performance of the system under different inductance values and inferred that the sensitivity of the system can reach −99 dBm at 100 MHz bandwidth.

IEEE Transactions on Applied Superconductivity•Apr 13, 2023•7 citations
Abstract We study the detection of very weak time‐periodic magnetic signals via a double‐junction (dc) Superconducting Quantum Interference Device (SQUID). The device, represented by two coupled nonlinear differential equations for the quantum mechanical junction phase differences, admits long‐time static or oscillatory solutions, the transition between them being easily controlled by experimentally accessible parameters. Gain is maximal when the device is tuned to the onset of the oscillatory solutions; i.e., when the minima in the 2D potential function disappear. We concentrate on the SQUID dynamics near this critical point and compute the oscillation frequency via a center manifold reduction of the full 2D dynamics. Knowing this frequency permits its exploitation as a detection/classification tool in magnetic remote sensing applications.
We study the detection of very weak time-periodic magnetic signals via a double-junction (dc) Superconducting Quantum Interference Device (SQUID). The device, represented by two coupled nonlinear differential equations for the quantum mechanical junction phases, admits of long-time static or oscillatory solutions, the transition being controllable by experimental parameters. Signal detection is optimal when the device is “tuned” to the onset of the oscillatory solutions; i.e., when the minima in the 2D potential function disappear. Modeling the device via a derived input-output transfer characteristic yields a response (quantified via the signal-to-noise ratio at the signal frequency) in good agreement with recent experiments. We also present some preliminary results pertaining to coupled dc SQUIDs, taking into account the (incoherent) thermal noise sources in each of the Josephson junctions. As might be expected from previous work, coupling the SQUIDs and/or summing their outputs enhances the response to the external signal.
We describe a new dc-superconducting quantum interference device (SQUID) circuit of the FM type, which has a large coefficient for converting an applied magnetic flux into a frequency of MHz band or a lower band. The circuit consists of a SQUID amplifier composed of two stages, formed by a superconducting weak link and two dc-SQUID elements with nonhysteretic characteristics. In the first stage, the weak link and dc-SQUID elements are connected in parallel and operated by a common bias voltage. Since the respective elements oscillate with high frequencies by the ac Josephson effect, the two frequencies interact with each other, so that, the first stage generates a beat signal of a lower frequency. In the second stage, the other dc-SQUID element with a intrinsic flux gain enhances the beat signal generated during the first stage. A theoretical analysis of the circuit with computer simulation shows that the beat frequency is a periodical function of the magnetic flux, and the SQUID amplifier with two stages can improve the flux sensitivity.
We present a study of the controllable nonlinear dynamics of a micromechanical beam coupled to a dc-SQUID (superconducting quantum interference device). The coupling between these systems places the modes of the beam in a highly nonlinear potential, whose shape can be altered by varying the bias current and applied flux of the SQUID. We detect the position of the beam by placing it in an optical cavity, which sets free the SQUID to be used solely for actuation. This enables us to probe the previously unexplored full parameter space of this device. We measure the frequency response of the beam and find that it displays a Duffing oscillator behavior which is periodic in the applied magnetic flux. To account for this, we develop a model based on the standard theory for SQUID dynamics. In addition, with the aim of understanding if the device can reach nonlinearity at the single phonon level, we use this model to show that the responsivity of the current circulating in the SQUID to the position of the beam can become divergent, with its magnitude limited only by noise. This suggests a direction for the generation of macroscopically distinguishable superposition states of the beam.
Conventional rf SQUIDs (superconducting quantum interference devices) consist of a superconducting loop interrupted by one weak link, and when read out via a tank circuit they produce output signals in the order of a few tens of microvolts. When the single weak link is replaced by a dc SQUID (a superconducting loop with two junctions) a so-called double quantization loop SQUID is formed. In this paper it is shown theoretically, and supported experimentally with thin-film devices of three different designs, that the general behaviour can be explained by a simplified picture of the fixed critical current of the single junction of the rf SQUID being replaced by an effective critical current of a dc SQUID loop that is varied by the applied magnetic flux (i.e., we have a rf SQUID with a variable β parameter). A more detailed analysis of the experimental data and the theory of this novel device reveals its interesting nonlinear character and shows the deviations from this simple picture. It is demonstrated experimentally that output signals in the order of ≥1 mV can be obtained with a suitable read-out mode for the tank circuit, a clear advantage when compared to conventional rf SQUIDs. With respect to dc SQUIDs, the coupling to integrated planar input coils will be unproblematic since no microwave resonances should occur in the structures.
One can use a direct current (dc) superconducting quantum interference device (SQUID) as a current amplifier by injecting a signal current Is into part of the superconducting loop and detecting the resultant change in critical current Ic. The current gain max ‖dIc/dIs‖ can be increased by making the inductances of the two arms of the SQUID asymmetric, thereby skewing the transfer function Ic vs Is. Detailed simulations of the device performance include an analysis of the impact of inductance and junction asymmetry on the transfer function. At 77 K a maximum current gain of 5 should be achievable albeit for frequencies below 1 GHz. An increase in the operating speed to 2 GHz can be achieved by reducing the gain to 2. We have fabricated asymmetric YBa2Cu3O7−x dc SQUIDs on SrTiO3 bicrystal substrates and operated them at 77 K. Using a second, readout SQUID to monitor changes in the critical current, we have achieved a low-frequency current gain up to 2.3. By coupling two SQUIDs together, we have increased the gain to 8.5.
Superconducting quantum interference devices (SQUIDs) are promising for detection of extremely weak power regimes for the Internet of Things and long-distance satellite networks. In low-frequency magnetic signal measurements, it has demonstrated superior performance over the traditional systems. We review the resistively and capacitively shunted junction model of dc SQUIDs and investigate its transfer function to magnetic flux signals while taking thermal fluctuation into account. We numerically evaluate the influence of bias current and bias flux signal to determine the operating parameters of the device. The performances related to SQUID ring inductance operating at 4.2 K and 77 K are demonstrated. Combined with common radio frequency front-end modules, including low-noise amplifier and low-pass filter, we evaluate the bit-error-rate performance of the system under different inductance values and inferred that the sensitivity of the system can reach −99 dBm at 100 MHz bandwidth.