Physical Review A

Thermal calcium atom interferometer with a phase resolution of a few milliradians based on a narrow-linewidth diode laser

Tomoya Akatsuka, Yoshihiro Mori, 伸彦 曾根, Yurie Ohtake, 守 町屋, Atsuo Morinaga

Published Aug 25, 2011• 4 citations
Publisher

Abstract

A symmetrical atom interferometer with a thermal calcium atom beam has been developed using a narrow linewidth diode laser stabilized to the resonance of a high-finesse cavity. The linewidth of the diode laser was estimated to be less than 1 Hz relative to the cavity resonance in noise measurement over the range of 100 Hz to 1 MHz, and the phase instability of the interference fringes obtained from the Allan deviation was improved to 2 mrad at an integration time of 300 s. Using this atom interferometer, the ac Stark phase shift between the ${}^{1}$${S}_{0}$ and ${}^{3}$${P}_{1}$ states of a Ca atom was measured as a function of a laser power near the resonance of the ${}^{1}{S}_{0}{\ensuremath{-}}^{1}\phantom{\rule{-0.16em}{0ex}}{P}_{1}$ transition at a wavelength of 423 nm. The decay rate of the ${}^{1}$${P}_{1}$ state was determined to be $\ensuremath{\gamma}=1.91(33)\ifmmode\times\else\texttimes\fi{}{10}^{8}$ s${}^{\ensuremath{-}1}$.

DOI
10.1103/physreva.84.023633

Related papers

Milliradian-phase-resolution atom interferometer with transparent electrodes for measurement of the Röntgen phase

卓 組谷, A. S. Akentyev, Yoshihiro Mori +2 more

An atom interferometer with a milliradian phase resolution was realized using a subhertz linewidth diode laser. The Allan deviation of the phase fluctuation decreased according to $\ensuremath{\sigma}/\mathrm{mrad}=70/\sqrt{\ensuremath{\tau}/\mathrm{s}}$ and reached 1 mrad at an integration time of 5000 s. With the transparent electrodes with a transmittance of 97%, the visibility of the interference was 8.5%, which was almost the same size as that with zero electric field. The dependence of the phase on the laser frequency was 0.1 \ensuremath{\mu}rad/Hz and that on the electric field was 1 mrad for 0.1 V/cm. Using the transition between the ${}^{3}{P}_{1}, m=0$ and ${}^{1}{S}_{0}, m=0$ states of Ca, the R\"ontgen phase was measured to be 3.0 \ifmmode\pm\else\textpm\fi{} 2.1 mrad for a measurement time of $4\ifmmode\times\else\texttimes\fi{}{10}^{4}\phantom{\rule{0.16em}{0ex}}\mathrm{s}$, which coincides with the expected one of 1.1 mrad within the measured uncertainty under an electric field of 1.92 kV/cm, a magnetic field of 20 mT, and an interference distance of 17 mm.

Physical Review A•Feb 24, 2016•3 citations

Direct measurement of the Aharonov-Casher phase and tensor Stark polarizability using a calcium atomic polarization interferometer

Shinya Yanagimachi, M. Kajiro, 守 町屋 +1 more

An atomic polarizing white-color interferometer composed of the wave packets in the $m=+1$ and $m=\ensuremath{-}1$ states of the excited ${}^{3}{P}_{1}$ state of Ca, has been developed using a thermal atomic beam excited by a pair of two resonant lights at two separate zones under a homogeneous magnetic field. The interferometer generated the Ramsey fringes as a detuning of the rf frequency between two resonant lights from the Zeeman-frequency shift, while it generates white-color interference fringes as a detuning of laser frequency. The interferometer was used for the direct and short-time measurement of the Aharonov-Casher phase by removing the main part of dc Stark phase shift and without the influence of the frequency fluctuation of a laser. The measured dependence of the Aharonov-Casher phase on the electric field agreed with the predicted one within a relative uncertainty of 2.9%. The tensor polarizability in the ${}^{3}{P}_{1}$ state was determined to be ${\ensuremath{\alpha}}_{2}=2.623\ifmmode\pm\else\textpm\fi{}0.015 \mathrm{k}\mathrm{H}\mathrm{z}/(\mathrm{k}\mathrm{V}/\mathrm{c}\mathrm{m}{)}^{2}$ from the frequency shift between the $m=+1$ and $m=\ensuremath{-}1$ states.

Physical Review A•Mar 14, 2002•28 citations

Phase shift induced from the dc Stark effect in an atom interferometer comprised of four copropagating laser beams

Atsuo Morinaga, Masato Nakamura, Takayuki Kurosu +1 more

We observed the phase shift of the atomic wave function induced from the dc Stark effect using an atom interferometer comprised of four copropagating traveling laser beams. We calculated the interference signal for the interferometer in the case of a thermal atomic beam. By comparing the observed interference fringes with the calculated ones, the difference between the polarizabilities of the $^{3}P_{1}$ state and the $^{1}S_{0}$ state of calcium was obtained to be $\ensuremath{\alpha}(^{3}P_{1})\ensuremath{-}\ensuremath{\alpha}(^{1}S_{0})=(13.4\ifmmode\pm\else\textpm\fi{}2.0)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}24}$ ${\mathrm{cm}}^{3}$. This value was consistent with that deduced from the Stark frequency shift.

Physical Review A•Jul 1, 1996•29 citations

Progress Toward A Thermal Beam Calcium Interferometer

Cristopher Erickson, Dan Christensen, Marshall Van Zijill +3 more

We report on the construction of a next-generation atom interferometer. Our research includes developing passive stabilization techniques, low-noise laser current drivers, high-speed scan-balancing lock circuits, and high-speed, low-noise photo-detecting units. Our efforts have lead to developing an extremely stable laser locked to an ultra-high finesse optical cavity for use in a Ramsey-Borde interferometer scheme. The interferometer itself is based on a thermal calcium beam and will be upgraded in the future to a dual species Ca/Sr interferometer sensitive enough to improve measurements of possible time variance of the fine structure constant. Emphasis is given to the construction of the laser used in developing the interferometer.

•Jan 1, 2007•0 citations

Dispersion-shaped ac Stark phase shift of Ca intercombination transitions with a time-domain atom interferometer

Tomoya Akatsuka, Kazuya Tanihara, Kenji Komito +2 more

A time-domain atom interferometer with a cold calcium atomic ensemble has been developed with a phase resolution ${\ensuremath{\sigma}}_{\ensuremath{\varphi}}=140/\sqrt{\ensuremath{\tau}}$ mrad/s${}^{1/2}$ at the integration time $\ensuremath{\tau}$. Using this atom interferometer, the dispersion-shaped ac Stark phase shift with a sharp reversal on resonance was demonstrated under the perturbation light near the resonance frequency of the ${}^{1}\phantom{\rule{-0.16em}{0ex}}{S}_{0},\phantom{\rule{4pt}{0ex}}{m}_{J}=0{\ensuremath{-}}^{3}\phantom{\rule{-0.16em}{0ex}}\phantom{\rule{-0.16em}{0ex}}{P}_{1},\phantom{\rule{4pt}{0ex}}{m}_{J}=\ensuremath{-}1$ transition. The phase shift was well described by a convolution of functions of the ac Stark potential and a Rabi excitation, and it was found that the lifetime of the ${}^{3}\phantom{\rule{-0.16em}{0ex}}{P}_{1}$ state is 0.45 \ifmmode\pm\else\textpm\fi{} 0.03 ms.

Physical Review A•Aug 28, 2012•1 citation

Low-frequency-noise diode laser for atom interferometry

Tatiana Nazarova, Christian Lisdat, F. Riehle +1 more

We investigate the influence of fast frequency fluctuations of an interrogation laser on the obtainable signal-to-noise ratio in Ramsey-Bordé atom interferometers. It is shown that the excessive high-frequency noise of diode lasers can degrade the signal-to-noise ratio significantly in an atom interferometer. To overcome these limitations, we have devised a low-noise light source by frequency filtering a diode laser in a high-finesse cavity and further amplifying the transmitted power by injection locking a solitary laser diode. When this laser source was used for atom interferometry with laser-cooled calcium atoms, the signal-to-noise ratio could be improved further by a factor of 3.5 compared with the use of the unfiltered 1 Hz linewidth laser source.

Journal of the Optical Society of America B•Sep 12, 2008•37 citations
A symmetrical atom interferometer with a thermal calcium atom beam has been developed using a narrow linewidth diode laser stabilized to the resonance of a high-finesse cavity. The linewidth of the diode laser was estimated to be less than 1 Hz relative to the cavity resonance in noise measurement over the range of 100 Hz to 1 MHz, and the phase instability of the interference fringes obtained from the Allan deviation was improved to 2 mrad at an integration time of 300 s. Using this atom interferometer, the ac Stark phase shift between the {}^{1}$${S}_{0} and {}^{3}$${P}_{1} states of a Ca atom was measured as a function of a laser power near the resonance of the 1S0\ensuremath−1P1{}^{1}{S}_{0}{\ensuremath{-}}^{1}\phantom{\rule{-0.16em}{0ex}}{P}_{1}1S0​\ensuremath−1P1​ transition at a wavelength of 423 nm. The decay rate of the {}^{1}$${P}_{1} state was determined to be \ensuremathγ=1.91(33)\ifmmode×\else\texttimes\fi108\ensuremath{\gamma}=1.91(33)\ifmmode\times\else\texttimes\fi{}{10}^{8}\ensuremathγ=1.91(33)\ifmmode×\else\texttimes\fi108 s\ensuremath−1{}^{\ensuremath{-}1}\ensuremath−1.
An atom interferometer with a milliradian phase resolution was realized using a subhertz linewidth diode laser. The Allan deviation of the phase fluctuation decreased according to $\ensuremath{\sigma}/\mathrm{mrad}=70/\sqrt{\ensuremath{\tau}/\mathrm{s}}$ and reached 1 mrad at an integration time of 5000 s. With the transparent electrodes with a transmittance of 97%, the visibility of the interference was 8.5%, which was almost the same size as that with zero electric field. The dependence of the phase on the laser frequency was 0.1 \ensuremath{\mu}rad/Hz and that on the electric field was 1 mrad for 0.1 V/cm. Using the transition between the 3P1,m=0{}^{3}{P}_{1}, m=03P1​,m=0 and 1S0,m=0{}^{1}{S}_{0}, m=01S0​,m=0 states of Ca, the R\"ontgen phase was measured to be 3.0 \ifmmode\pm\else\textpm\fi{} 2.1 mrad for a measurement time of $4\ifmmode\times\else\texttimes\fi{}{10}^{4}\phantom{\rule{0.16em}{0ex}}\mathrm{s}$, which coincides with the expected one of 1.1 mrad within the measured uncertainty under an electric field of 1.92 kV/cm, a magnetic field of 20 mT, and an interference distance of 17 mm.
An atomic polarizing white-color interferometer composed of the wave packets in the m=+1m=+1m=+1 and $m=\ensuremath{-}1$ states of the excited 3P1{}^{3}{P}_{1}3P1​ state of Ca, has been developed using a thermal atomic beam excited by a pair of two resonant lights at two separate zones under a homogeneous magnetic field. The interferometer generated the Ramsey fringes as a detuning of the rf frequency between two resonant lights from the Zeeman-frequency shift, while it generates white-color interference fringes as a detuning of laser frequency. The interferometer was used for the direct and short-time measurement of the Aharonov-Casher phase by removing the main part of dc Stark phase shift and without the influence of the frequency fluctuation of a laser. The measured dependence of the Aharonov-Casher phase on the electric field agreed with the predicted one within a relative uncertainty of 2.9%. The tensor polarizability in the 3P1{}^{3}{P}_{1}3P1​ state was determined to be ${\ensuremath{\alpha}}_{2}=2.623\ifmmode\pm\else\textpm\fi{}0.015 \mathrm{k}\mathrm{H}\mathrm{z}/(\mathrm{k}\mathrm{V}/\mathrm{c}\mathrm{m}{)}^{2}$ from the frequency shift between the m=+1m=+1m=+1 and $m=\ensuremath{-}1$ states.
We observed the phase shift of the atomic wave function induced from the dc Stark effect using an atom interferometer comprised of four copropagating traveling laser beams. We calculated the interference signal for the interferometer in the case of a thermal atomic beam. By comparing the observed interference fringes with the calculated ones, the difference between the polarizabilities of the 3P1^{3}P_{1}3P1​ state and the 1S0^{1}S_{0}1S0​ state of calcium was obtained to be $\ensuremath{\alpha}(^{3}P_{1})\ensuremath{-}\ensuremath{\alpha}(^{1}S_{0})=(13.4\ifmmode\pm\else\textpm\fi{}2.0)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}24}$ cm3{\mathrm{cm}}^{3}cm3. This value was consistent with that deduced from the Stark frequency shift.
We report on the construction of a next-generation atom interferometer. Our research includes developing passive stabilization techniques, low-noise laser current drivers, high-speed scan-balancing lock circuits, and high-speed, low-noise photo-detecting units. Our efforts have lead to developing an extremely stable laser locked to an ultra-high finesse optical cavity for use in a Ramsey-Borde interferometer scheme. The interferometer itself is based on a thermal calcium beam and will be upgraded in the future to a dual species Ca/Sr interferometer sensitive enough to improve measurements of possible time variance of the fine structure constant. Emphasis is given to the construction of the laser used in developing the interferometer.
A time-domain atom interferometer with a cold calcium atomic ensemble has been developed with a phase resolution ${\ensuremath{\sigma}}_{\ensuremath{\varphi}}=140/\sqrt{\ensuremath{\tau}}$ mrad/s1/2{}^{1/2}1/2 at the integration time $\ensuremath{\tau}$. Using this atom interferometer, the dispersion-shaped ac Stark phase shift with a sharp reversal on resonance was demonstrated under the perturbation light near the resonance frequency of the ${}^{1}\phantom{\rule{-0.16em}{0ex}}{S}_{0},\phantom{\rule{4pt}{0ex}}{m}_{J}=0{\ensuremath{-}}^{3}\phantom{\rule{-0.16em}{0ex}}\phantom{\rule{-0.16em}{0ex}}{P}_{1},\phantom{\rule{4pt}{0ex}}{m}_{J}=\ensuremath{-}1$ transition. The phase shift was well described by a convolution of functions of the ac Stark potential and a Rabi excitation, and it was found that the lifetime of the 3P1{}^{3}\phantom{\rule{-0.16em}{0ex}}{P}_{1}3P1​ state is 0.45 \ifmmode\pm\else\textpm\fi{} 0.03 ms.
We investigate the influence of fast frequency fluctuations of an interrogation laser on the obtainable signal-to-noise ratio in Ramsey-Bordé atom interferometers. It is shown that the excessive high-frequency noise of diode lasers can degrade the signal-to-noise ratio significantly in an atom interferometer. To overcome these limitations, we have devised a low-noise light source by frequency filtering a diode laser in a high-finesse cavity and further amplifying the transmitted power by injection locking a solitary laser diode. When this laser source was used for atom interferometry with laser-cooled calcium atoms, the signal-to-noise ratio could be improved further by a factor of 3.5 compared with the use of the unfiltered 1 Hz linewidth laser source.