© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chemical Physics Letters

General solution of the three-level maser problem, using a density matrix technique

Christopher Feuillade, John G. Baker, C. Böttcher

Published May 1, 1976• 18 citations
Publisher
DOI
10.1016/0009-2614(76)80133-9

Related papers

Model for Transient Oscillations in a Three-Level Optical Maser

Jerome I. Kaplan, Robert Eugene Zier

The transient response of a three-level optical maser is calculated for a density of homogeneously broadened atoms coupled to one homogeneously broadened cavity mode. The atoms are treated in terms of the density matrix and the cavity mode is treated classically. Solutions are found analytically for the steady state and for the linearized form of two simplifications of the general equations. These special solutions have been previously obtained by Bloom and Statz and de Mars. Numerical solutions are found for a certain set of parameters. The response linewidth is found assuming one cavity mode coupled to a density of inhomogeneously broadened atoms.

Journal of Applied Physics•Jul 1, 1962•12 citations

Noise and Absorption Spectra in Three-Level Masers

P. N. Butcher

Quantum Electronics•Jan 1, 1960•0 citations

Exact Solutions for Many-Level Multiple-Resonance Problems

Karl F. Freed

The matrix elements of the time-development operator are obtained exactly for the influence of many resonant or near-resonant fields on a system with a finite number of levels for arbitrary initial conditions in a wide class of problems. Perturbative techniques are presented which enable the exact treatment of all perturbations to a desired order. As examples, a three-level double-resonance and two eight-level triple-resonance systems are given. The applications of these exact solutions to the treatment of perturbations, including relaxation phenomena, are presented using both standard-perturbation-theory and density-matrix techniques.

The Journal of Chemical Physics•Aug 15, 1965•23 citations

The theory of the two-level solid-state maser

Ya I Khanin

Radiophysics and Quantum Electronics•Jan 1, 1968•0 citations

Optical and Cross Relaxation Maser Level Populations by Partial Distribution

William A. Barker, J. D. Keating

The method of partial distributions is used to calculate the population distribution of three level maser systems in which spontaneous emission and cross relaxation as well as thermal relaxation and induced absorption processes are included. The results obtained are in agreement with the solution of the relevant rate equations. The method has the advantage of speed and suggestiveness. Two examples are presented: (1) A three level optical maser is analyzed in which one spontaneous emission transition probability is included. The solution in this example does not make the linear approximation to the Boltzmann factor. (2). A three level microwave maser is analyzed in which one cross relaxation mechanism is included. The solution to this problem by the method of partial distributions does require use of the linear approximation to the Boltzmann factor.

Applied Optics•Jan 1, 1962•3 citations

Behavior of a Two-Level Solid-State Maser

I. R. Senitzky

Physical Review Letters•Sep 1, 1958•17 citations
The transient response of a three-level optical maser is calculated for a density of homogeneously broadened atoms coupled to one homogeneously broadened cavity mode. The atoms are treated in terms of the density matrix and the cavity mode is treated classically. Solutions are found analytically for the steady state and for the linearized form of two simplifications of the general equations. These special solutions have been previously obtained by Bloom and Statz and de Mars. Numerical solutions are found for a certain set of parameters. The response linewidth is found assuming one cavity mode coupled to a density of inhomogeneously broadened atoms.
The matrix elements of the time-development operator are obtained exactly for the influence of many resonant or near-resonant fields on a system with a finite number of levels for arbitrary initial conditions in a wide class of problems. Perturbative techniques are presented which enable the exact treatment of all perturbations to a desired order. As examples, a three-level double-resonance and two eight-level triple-resonance systems are given. The applications of these exact solutions to the treatment of perturbations, including relaxation phenomena, are presented using both standard-perturbation-theory and density-matrix techniques.
The method of partial distributions is used to calculate the population distribution of three level maser systems in which spontaneous emission and cross relaxation as well as thermal relaxation and induced absorption processes are included. The results obtained are in agreement with the solution of the relevant rate equations. The method has the advantage of speed and suggestiveness. Two examples are presented: (1) A three level optical maser is analyzed in which one spontaneous emission transition probability is included. The solution in this example does not make the linear approximation to the Boltzmann factor. (2). A three level microwave maser is analyzed in which one cross relaxation mechanism is included. The solution to this problem by the method of partial distributions does require use of the linear approximation to the Boltzmann factor.