Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Photon-number uncertainty in a superconducting transition edge sensor beyond resolved-photon-number determination

Zachary H. Levine, Boris L. Glebov, Alan L. Migdall, Thomas Gerrits, Brice Calkins, Adriana E. Lita, Sae Woo Nam

Published Sep 9, 2014• 9 citations
Publisher

Abstract

As part of an effort to extend fundamental single-photon measurements into the macroscopic regime, we explore how best to assign photon-number uncertainties to output waveforms of a superconducting transition edge sensor and how those assignments change over that extended dynamic range. Three methods are used. At the lowest photon numbers (up to 20 photons), the widths of histogram peaks of individual waveforms are used to determine the uncertainty. From 100 to 1000 photons, mean waveforms are used to create a photon-number scale. The photon-number uncertainty of the detector in this range is given by the excess of the total variance of the photon number obtained from individual waveforms on this scale beyond the shot noise due to the source. In the midrange (from 10 to 100 photons), including a range where the two other methods do not produce definitive results, we fit waveforms to several adjacent mean waveforms to estimate the photon-number uncertainty. A one-standard-deviation uncertainty in photon number of no more than ±1 is found for pulses of up to 100 photons.

DOI
10.1364/josab.31.000b20

Related papers

Extending single-photon optimized superconducting transition edge sensors beyond the single-photon counting regime

Thomas Gerrits, Brice Calkins, Nathan A. Tomlin +4 more

Typically, transition edge sensors resolve photon number of up to 10 or 20 photons, depending on the wavelength and TES design. We extend that dynamic range up to 1000 photons, while maintaining sub-shot noise detection process uncertainty of the number of detected photons and beyond that show a monotonic response up to ≈ 6 · 10(6) photons in a single light pulse. This mode of operation, which heats the sensor far beyond its transition edge into the normal conductive regime, offers a technique for connecting single-photon-counting measurements to radiant-power measurements at picowatt levels. Connecting these two usually incompatible operating regimes in a single detector offers significant potential for directly tying photon counting measurements to conventional cryogenic radiometric standards. In addition, our measurements highlight the advantages of a photon-number state source over a coherent pulse source as a tool for characterizing such a detector.

Optics Express•Oct 2, 2012•55 citations

Algorithm for finding clusters with a known distribution and its application to photon-number resolution using a superconducting transition-edge sensor

Zachary H. Levine, Thomas Gerrits, Alan L. Migdall +4 more

Improving photon-number resolution of single-photon sensitive detectors is important for many applications, as is extending the range of such detectors. Here we seek improved resolution for a particular superconducting transition-edge sensor (TES) through better processing of the TES output waveforms. With that aim, two algorithms to extract number resolution from TES output waveforms are compared. The comparison is done by processing waveform data sets from a TES illuminated at nine illumination levels by a pulsed laser at 1550 nm. The algorithms are used to sort the individual output waveforms and then create clusters associated with individual photon numbers. The first uses a dot product with the waveform mean (for each illumination level), while the second uses K-means clustering modified to include knowledge of the Poisson distribution. The first algorithm is shown to distinguish adjacent peaks associated with photon numbers up to 19, whereas the second algorithm distinguishes photon numbers up to 23, using the same data.

Journal of the Optical Society of America B•Jul 20, 2012•37 citations

Extending Single-Photon Optimized Superconducting Transition Edge Sensors beyond the single-photon counting regime

Thomas Gerrits, Brice Calkins, Adriana E. Lita +3 more

We illuminate a photon-number-resolving transition edge sensor with strong pulses of light containing up to 6.7 million photons (0.85 pJ per pulse). These bright pulses heat the sensor far beyond its transition edge into the normal resistance regime. We show that the sensor operates from the single-photon-counting regime to picowatt levels of light and that the detection noise is below shot-noise for up to 1000 photons.

Conference on Lasers and Electro-Optics•Jan 1, 2012•2 citations

Photon-number uncertainty in a superconducting transition-edge sensor beyond resolved-photon-number determination | NIST

Zachary H. Levine, Boris L. Glebov, Alan L. Migdall +4 more

Journal of the Optical Society of America A•Sep 10, 2014•0 citations

Precisely determining photon-number in real time

Leonardo Assis Morais, Till J. Weinhold, Marcelo Pereira de Almeida +7 more

Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the quantum property of photon-number, n ^ = a ^ † a ^ , for energies from 0.6-2.33eV. However, achieving optimal energy resolution requires considerable data acquisition – on the order of 1GB/min – followed by post-processing, which does not allow access to energy information in real time. Here we use a custom hardware processor to process TES pulses while new detections are still being registered, allowing photon-number to be measured in real time as well as reducing data requirements by orders-of-magnitude. We resolve photon number up to n = 16 – achieving up to parts-per-billion discrimination for low photon numbers on the fly – providing transformational capacity for applications of TES detectors from astronomy through to quantum technology.

arXiv:2012.10158•Quantum•May 23, 2024•42 citations

Photon-number discriminating superconducting transition-edge sensors

M. Rajteri, E. Taralli, Chiara Portesi +2 more

Photon-number discriminating detectors are fundamentals for new quantum photon-based standards. We report the results on superconducting transition-edge sensors based on Ti/Au and Ti/Pd bilayers allowing pulses containing up to five photons to be discriminated.

Metrologia•Jun 2, 2009•22 citations
As part of an effort to extend fundamental single-photon measurements into the macroscopic regime, we explore how best to assign photon-number uncertainties to output waveforms of a superconducting transition edge sensor and how those assignments change over that extended dynamic range. Three methods are used. At the lowest photon numbers (up to 20 photons), the widths of histogram peaks of individual waveforms are used to determine the uncertainty. From 100 to 1000 photons, mean waveforms are used to create a photon-number scale. The photon-number uncertainty of the detector in this range is given by the excess of the total variance of the photon number obtained from individual waveforms on this scale beyond the shot noise due to the source. In the midrange (from 10 to 100 photons), including a range where the two other methods do not produce definitive results, we fit waveforms to several adjacent mean waveforms to estimate the photon-number uncertainty. A one-standard-deviation uncertainty in photon number of no more than ±1 is found for pulses of up to 100 photons.
Typically, transition edge sensors resolve photon number of up to 10 or 20 photons, depending on the wavelength and TES design. We extend that dynamic range up to 1000 photons, while maintaining sub-shot noise detection process uncertainty of the number of detected photons and beyond that show a monotonic response up to ≈ 6 · 10(6) photons in a single light pulse. This mode of operation, which heats the sensor far beyond its transition edge into the normal conductive regime, offers a technique for connecting single-photon-counting measurements to radiant-power measurements at picowatt levels. Connecting these two usually incompatible operating regimes in a single detector offers significant potential for directly tying photon counting measurements to conventional cryogenic radiometric standards. In addition, our measurements highlight the advantages of a photon-number state source over a coherent pulse source as a tool for characterizing such a detector.
Improving photon-number resolution of single-photon sensitive detectors is important for many applications, as is extending the range of such detectors. Here we seek improved resolution for a particular superconducting transition-edge sensor (TES) through better processing of the TES output waveforms. With that aim, two algorithms to extract number resolution from TES output waveforms are compared. The comparison is done by processing waveform data sets from a TES illuminated at nine illumination levels by a pulsed laser at 1550 nm. The algorithms are used to sort the individual output waveforms and then create clusters associated with individual photon numbers. The first uses a dot product with the waveform mean (for each illumination level), while the second uses K-means clustering modified to include knowledge of the Poisson distribution. The first algorithm is shown to distinguish adjacent peaks associated with photon numbers up to 19, whereas the second algorithm distinguishes photon numbers up to 23, using the same data.
Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the quantum property of photon-number, n ^ = a ^ † a ^ , for energies from 0.6-2.33eV. However, achieving optimal energy resolution requires considerable data acquisition – on the order of 1GB/min – followed by post-processing, which does not allow access to energy information in real time. Here we use a custom hardware processor to process TES pulses while new detections are still being registered, allowing photon-number to be measured in real time as well as reducing data requirements by orders-of-magnitude. We resolve photon number up to n = 16 – achieving up to parts-per-billion discrimination for low photon numbers on the fly – providing transformational capacity for applications of TES detectors from astronomy through to quantum technology.