We report sympathetic cooling of
113Cd
+ by laser-cooled
40Ca
+ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of
113Cd
+ ions was achieved. The temperature of these ions was measured at
90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of
2×10−17. Up to
4.2×105 Cd
+ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still
105 Cd
+ ions present, indicating that this Ca
+--Cd
+ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca
+ lasers and fluorescence, which was carefully estimated to an accuracy of
5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
The development of a transportable microwave frequency standard based on the ground-state transition of 171Yb+ at ∼12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dimensions 260 × 194 × 335 mm. Laser outputs at 369 nm (for cooling), 399 nm (photoionisation), 935 nm (repumping), and 760 nm (state clearout) are combined in a fiber arrangement for delivery to our linear ion trap and we demonstrate this system by cooling of 171Yb+ ions. Additionally, we demonstrate that the lasers at 935 nm and 760 nm are close in frequency to water vapor and oxygen absorption lines, respectively; specifically, at 760 nm, we show that one 171Yb+ transition is within the pressure broadened profile of an oxygen line. These molecular transitions form convenient wavelength references for the stabilization of lasers for a 171Yb+ frequency standard.
We report the laser cooling and confinement of Cd atoms in a magneto-optical trap and characterize the loading process from the background Cd vapor. The trapping laser drives the $^{1}S_{0}\ensuremath{\rightarrow}^{1}P_{1}$ transition at
229nm in this two-electron atom and also photoionizes atoms directly from the
1P1 state. This photoionization overwhelms the other loss mechanisms and allows a direct measurement of the photoionization cross section, which we measure to be $2(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.3em}{0ex}}{\mathrm{cm}}^{2}$ from the
1P1 state. When combined with nearby laser-cooled and trapped
Cd+ ions, this apparatus could facilitate studies in ultracold interactions between atoms and ions.