Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Laser cooling of Cd + ions using a microwave transition as a repumping process

U. Tanaka, S. Urabe, Masayoshi Watanabe

Published Dec 23, 2003• 11 citations
Publisher
DOI
10.1007/s00340-003-1316-2

Related papers

Laser Cooling Of Cd/ sup -/ Ions In A Linear Trap

U. Tanaka, Hidetsuka Imajo, K. Hayasaka +4 more

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jan 1, 1997•0 citations

Sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for Microwave Ion Clocks

J. Z. Han, H. R. Qin, Limin Guo +6 more

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured at $90(10)$ mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of $2\times10^{-17}$. Up to $4.2\times10^5$ Cd$^+$ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still $10^5$ Cd$^+$ ions present, indicating that this Ca$^+$--Cd$^+$ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca$^+$ lasers and fluorescence, which was carefully estimated to an accuracy of $5.4(0.5)\times10^{-17}$ using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

arXiv:2002.04228•Feb 11, 2020•0 citations

Laser Cooling of Trapped Ions

Wayne M. Itano, Jonas Bergquist, J. J. Bollinger +1 more

•Jan 1, 1991•5 citations

Compact laser system for a laser-cooled ytterbium ion microwave frequency standard

Sean Mulholland, Hugh A. Klein, G. P. Barwood +6 more

The development of a transportable microwave frequency standard based on the ground-state transition of 171Yb+ at ∼12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dimensions 260 × 194 × 335 mm. Laser outputs at 369 nm (for cooling), 399 nm (photoionisation), 935 nm (repumping), and 760 nm (state clearout) are combined in a fiber arrangement for delivery to our linear ion trap and we demonstrate this system by cooling of 171Yb+ ions. Additionally, we demonstrate that the lasers at 935 nm and 760 nm are close in frequency to water vapor and oxygen absorption lines, respectively; specifically, at 760 nm, we show that one 171Yb+ transition is within the pressure broadened profile of an oxygen line. These molecular transitions form convenient wavelength references for the stabilization of lasers for a 171Yb+ frequency standard.

arXiv:1811.10451•Review of Scientific Instruments•Mar 1, 2019•22 citations

Magneto-optical trapping of cadmium

Kathy-Anne Brickman, M.-S. Chang, M. Acton +5 more

We report the laser cooling and confinement of Cd atoms in a magneto-optical trap and characterize the loading process from the background Cd vapor. The trapping laser drives the $^{1}S_{0}\ensuremath{\rightarrow}^{1}P_{1}$ transition at $229\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ in this two-electron atom and also photoionizes atoms directly from the $^{1}P_{1}$ state. This photoionization overwhelms the other loss mechanisms and allows a direct measurement of the photoionization cross section, which we measure to be $2(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.3em}{0ex}}{\mathrm{cm}}^{2}$ from the $^{1}P_{1}$ state. When combined with nearby laser-cooled and trapped ${\mathrm{Cd}}^{+}$ ions, this apparatus could facilitate studies in ultracold interactions between atoms and ions.

arXiv:0706.1608•Physical Review A•Oct 11, 2007•56 citations

Laser Cooling of Atoms and Ions

F. G. Major

Springer eBooks•Jan 1, 2007•2 citations
Sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for Microwave Ion Clocks
We report sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113^{113}113Cd+^++ ions was achieved. The temperature of these ions was measured at 90(10)90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10−172\times10^{-17}2×10−17. Up to 4.2×1054.2\times10^54.2×105 Cd+^++ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^5105 Cd+^++ ions present, indicating that this Ca+^++--Cd+^++ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+^++ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10−175.4(0.5)\times10^{-17}5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
The development of a transportable microwave frequency standard based on the ground-state transition of 171Yb+ at ∼12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dimensions 260 × 194 × 335 mm. Laser outputs at 369 nm (for cooling), 399 nm (photoionisation), 935 nm (repumping), and 760 nm (state clearout) are combined in a fiber arrangement for delivery to our linear ion trap and we demonstrate this system by cooling of 171Yb+ ions. Additionally, we demonstrate that the lasers at 935 nm and 760 nm are close in frequency to water vapor and oxygen absorption lines, respectively; specifically, at 760 nm, we show that one 171Yb+ transition is within the pressure broadened profile of an oxygen line. These molecular transitions form convenient wavelength references for the stabilization of lasers for a 171Yb+ frequency standard.
We report the laser cooling and confinement of Cd atoms in a magneto-optical trap and characterize the loading process from the background Cd vapor. The trapping laser drives the $^{1}S_{0}\ensuremath{\rightarrow}^{1}P_{1}$ transition at 229nm229\phantom{\rule{0.3em}{0ex}}\mathrm{nm}229nm in this two-electron atom and also photoionizes atoms directly from the 1P1^{1}P_{1}1P1​ state. This photoionization overwhelms the other loss mechanisms and allows a direct measurement of the photoionization cross section, which we measure to be $2(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.3em}{0ex}}{\mathrm{cm}}^{2}$ from the 1P1^{1}P_{1}1P1​ state. When combined with nearby laser-cooled and trapped Cd+{\mathrm{Cd}}^{+}Cd+ ions, this apparatus could facilitate studies in ultracold interactions between atoms and ions.