Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Soviet Journal of Quantum Electronics

Use of two-photon light for absolute calibration of photoelectric detectors

Давид Николаевич Клышко

Published Sep 30, 1980• 230 citations
Publisher

Abstract

A description is given of a method for calibrating photodetectors based on some characteristics of the statistics of the field of spontaneous parametric light scattering. A phenomenological theory of parametric scattering is used to demonstrate that photons are only emitted in pairs. It is shown that, in principle, a priori information on the two-photon character and directionality of parametrically scattered light can be used for absolute calibration of photodetectors operated both in the analog linear regime and in the discrete photoelectron pulse counting regime.

DOI
10.1070/qe1980v010n09abeh010660

Related papers

Absolute standardless calibration of photodetectors based on quantum two-photon fields

Alexander N. Penin, Alexander V. Sergienko

A new method of absolute calibration of photodetectors based on a nonclassical effect in nonlinear optics is discussed. The combined influence of a monochromatic flux of pump photons and quantum vacuum noise on a nonlinear crystal with no center of symmetry results in the appearance of rigorously correlated pairs of photons with continuous spectral distribution in the spontaneous parametric scattering of light (spontaneous parametric downconversion) process. The presence of an optical field in a broad spectral range created by the two-photon states (biphotons) makes it possible to develop a new method of measuring the spectral distribution of the absolute value of the quantum efficiency of photodetectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources (étalons). The feasibility of the method is demonstrated on different types of photomultiplier tube.

Applied Optics•Sep 1, 1991•64 citations

Measurement of quantum efficiency of avalanche photodetectors based on quantum two-photon field

A. Czitrovszky, Alexander V. Sergienko

A pair of rigorously correlated photons (biphotons) from parametric down conversion makes it possible to use them for measuring the absolute value of the quantum efficiency of the optical detectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources. Using this method the quantum efficiency of EG&G avalanche photodetectors was determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 19, 1998•3 citations

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN-CONVERSION BIPHOTON FIELD

L. J. Sun, Zhiyu Yang

A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.

Acta Physica Sinica•Jan 1, 2000•0 citations

Efficient generator of a two-photon field of visible radiation

A A Malygin, A N Penin, Alexander V. Sergienko

A description is given of an optimal system for parametric conversion of one-photon light into a two-photon field. This system is suitable for absolute calibration of photodetectors throughout the visible range without the use of a standard source for comparison. Tuning curves of such a parametric converter are calculated and verified experimentally. The efficiency achieved in this method of generation of a two-photon field (10 6 of two-photon pairs per second in a spectral band Δ ν = 10 cm −1 wide) makes it possible to calibrate photodetectors to within at least 3–4% after accumulation of a signal for a time of the order of 100 sec.

Soviet Journal of Quantum Electronics•Jul 31, 1981•15 citations

Elementary responses of analog photodetectors and absolute calibration of their efficiency

Daniil A. Safronenkov, Pavel A. Prudkovskii, A. V. Osipenkov +1 more

A modified Klyshko method for standardless calibration of analog photodetector efficiencies is suggested and experimentally implemented. The method is based on the measurement of the number of incident photons using correlation properties of biphotons generated under spontaneous parametric downconversion, and on the determination of the mean number of discrete elementary responses of a photodetector by deconvoluting the statistical distribution of the output photocurrents. As an example, the generalized efficiency of an analog photomultiplier is measured as the ratio of the average number of elementary current responses to the average number of incident photons. The statistical properties of the elementary responses of an analog photodetector depend not only on the detector itself, but also on the parameters of the subsequent electronic circuit. Nevertheless, it has been shown that the generalized efficiency determined by this way allows one to calibrate the photon fluxes by the analog photodetector without involvement of any reference sources or detectors.

Journal of Applied Physics•May 8, 2025•4 citations

Absolute calibration of photodetectors: photocurrent multiplication versus photocurrent subtraction

I. N. Agafonov, Maria V. Chekhova, T. Sh. Iskhakov +3 more

We report testing of the new absolute method of photodetector calibration based on the difference-signal measurement for two-mode squeezed vacuum by comparison with the traditional absolute method based on coincidence counting. Using low-gain parametric downconversion, we have measured the quantum efficiency of a counting detector by both methods. The difference-signal method was adapted for the counting detectors by taking into account the dead-time effect.

arXiv:1012.3248•Optics Letters•Apr 4, 2011•20 citations
A description is given of a method for calibrating photodetectors based on some characteristics of the statistics of the field of spontaneous parametric light scattering. A phenomenological theory of parametric scattering is used to demonstrate that photons are only emitted in pairs. It is shown that, in principle, a priori information on the two-photon character and directionality of parametrically scattered light can be used for absolute calibration of photodetectors operated both in the analog linear regime and in the discrete photoelectron pulse counting regime.
A new method of absolute calibration of photodetectors based on a nonclassical effect in nonlinear optics is discussed. The combined influence of a monochromatic flux of pump photons and quantum vacuum noise on a nonlinear crystal with no center of symmetry results in the appearance of rigorously correlated pairs of photons with continuous spectral distribution in the spontaneous parametric scattering of light (spontaneous parametric downconversion) process. The presence of an optical field in a broad spectral range created by the two-photon states (biphotons) makes it possible to develop a new method of measuring the spectral distribution of the absolute value of the quantum efficiency of photodetectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources (étalons). The feasibility of the method is demonstrated on different types of photomultiplier tube.
A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.
A description is given of an optimal system for parametric conversion of one-photon light into a two-photon field. This system is suitable for absolute calibration of photodetectors throughout the visible range without the use of a standard source for comparison. Tuning curves of such a parametric converter are calculated and verified experimentally. The efficiency achieved in this method of generation of a two-photon field (10 6 of two-photon pairs per second in a spectral band Δ ν = 10 cm −1 wide) makes it possible to calibrate photodetectors to within at least 3–4% after accumulation of a signal for a time of the order of 100 sec.
A modified Klyshko method for standardless calibration of analog photodetector efficiencies is suggested and experimentally implemented. The method is based on the measurement of the number of incident photons using correlation properties of biphotons generated under spontaneous parametric downconversion, and on the determination of the mean number of discrete elementary responses of a photodetector by deconvoluting the statistical distribution of the output photocurrents. As an example, the generalized efficiency of an analog photomultiplier is measured as the ratio of the average number of elementary current responses to the average number of incident photons. The statistical properties of the elementary responses of an analog photodetector depend not only on the detector itself, but also on the parameters of the subsequent electronic circuit. Nevertheless, it has been shown that the generalized efficiency determined by this way allows one to calibrate the photon fluxes by the analog photodetector without involvement of any reference sources or detectors.