Journal of Physics E Scientific Instruments

A low-noise parametric preamplifier for SQUIDS

G. J. Ehnholm, S. T. Islander, P Juvonen

Published May 1, 1979• 0 citations
Publisher

Abstract

A parametric preamplifier of the up-converting type is described for use with SQUIDS. The amplifier works in a self-oscillatory mode. The theory of its operation, including equations for gain and noise properties, is presented. The design and performance of a built amplifier are described and possible improvements in the results discussed.

DOI
10.1088/0022-3735/12/5/014

Related papers

An ultra-low-noise preamplifier using superconducting quantum devices

A. Davidson, Ronald S. Newbower, M. R. Beasley

The application of superconducting (SQUID) galvanometers as low-noise preamplifiers with considerable bandwidth is explored. The important role of negative feedback in maximizing the bandwidth of these preamplifiers is carefully analyzed. Also discussed is the design and construction of superconducting impedance matching transformers suitable for making the unexcelled noise characteristics of these amplifiers available over a wide range of source impedances. A working preamplifier is described which has exhibited a maximum bandwidth of 10 kHz and noise temperatures in the liquid helium temperature range or below for all source impedances up to a few ohms. The operating characteristics of this preamplifier are compared to the best conventional room temperature amplifiers and are found to be superior for source impedances less than ∼10 Ω.

Review of Scientific Instruments•Jun 1, 1974•25 citations

Improved dc SQUID read-out electronics with low 1/f noise preamplifier

D. Drung

An improved read-out electronics without flux modulation for dc superconducting quantum interference devices (dc SQUIDs) is presented where the preamplifier is directly coupled to the SQUID. Compared to our previous designs, the 1/f voltage and current noise levels of the preamplifier were reduced by about a factor of 4 (rms) by using bipolar matched transistors instead of operational amplifiers at the input. Three types of flux-locked-loop electronics were developed and successfully tested: a low-power (120 mW) version for large multichannel arrays, a high-speed version with a 15 MHz bandwidth and a very fast (300 ns) reset mode, and a low-noise (0.44 nV/Hz) version with a fast and precise bias reversal circuit. The flux-locked-loop electronics are compatible with each other, so that only one type of low-power (180 mW) control unit is required to operate them. All essential specifications of practical SQUID systems (noise, dynamic behavior, and temperature stability) were determined by using liquid-helium and liquid-nitrogen cooled SQUIDs, respectively.

Review of Scientific Instruments•Nov 1, 1997•43 citations

A low-noise, two-stage DC SQUID amplifier with high bandwidth and dynamic range

R. Cantor, L. P. Lee, Andrei N. Matlashov +1 more

We describe a low-noise, two-stage dc Superconducting QUantum Interference Device (SQUID) amplifier that is designed for applications requiring high bandwidth and dynamic range. The output signal of a low-noise SQUID in the input stage coherently modulates a series array of identical SQUIDs in the output stage via a common modulation line. The input stage is designed so its output signal does not produce multiple modulation periods in the output stage. The output stage is designed to have sufficient gain so the output noise is dominated by the amplified noise of the input SQUID and exceeds the noise of a preamplifier in the room temperature readout electronics. The SQUID amplifier may therefore be operated without flux modulation or any impedance matching network, resulting in a large dynamic range and high bandwidth.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•11 citations

Low noise parametric upconversion with a self-pumped Josephson junction

Helmut Kanter

Experimental results are reported on a Josephson parametric upconverting amplifier which is self-pumped via the internal Josephson oscillations derived from a dc bias voltage. A niobium point-contact SQUID is simultaneously coupled to a 115-MHz tank circuit and a 9-GHz cavity. Josephson oscillations at 9 GHz produce parametric upconversion of power in the 115-MHz circuit to sidebands at 9±0.115 GHz with measured power gain of 25. The amplifier noise temperature, referred to the input at 115 MHz, was established to be <15 K by varying the temperature of an input termination from 4.2 to 300 K. This result establishes the behavior of self-pumped SQUID upconverters at microwave frequencies and demonstrates that the achievable noise performance is not greatly in excess of the thermal limit.

Journal of Applied Physics•May 1, 1975•3 citations

Demonstration of a microwave SQUID multiplexer with pre-amplification from a kinetic inductance traveling-wave parametric amplifier

Michael R. Vissers, M. Malnou, Jiansong Gao +7 more

Kinetic inductance traveling-wave parametric amplifiers (KITs) are under development for the read out of large cryogenic detector arrays. We present new KIT designs based on 20nm NbTiN films patterned by use of standard optical photolithography. We report device gain, bandwidth, and noise properties, which approach the quantum limit. In addition, we demonstrate a KIT preamplifier with a microwave SQUID multiplexer. The improved input referred current noise, as compared to standard HEMT readout, opens up new possibilities for cryogenic receivers. We discuss these benefits.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Dec 12, 2020•5 citations

Shunted Josephson tunnel junctions: High-frequency, self-pumped low noise amplifiers

Nils P. Calander, T. Claeson, S. Rudner

The high-frequency amplification properties of transformer coupled, resistively shunted Josephson tunnel junctions have been investigated. The importance of the shunt loop inductance is stressed. It allows a high cutoff frequency, of significance for good high-frequency performance. The self-pumped parametric amplifier showed none of the excessive noise rise, which has hitherto plagued the development of externally pumped Josephson junction amplifiers. Around 10 GHz, we estimated a noise temperature less than 30 K for an amplifier pumped by a Josephson oscillation with a frequency well above twice the signal frequency. The corresponding gain of 5 dB may be increased in a better impedance matched circuit. The gain was very stable against variations in the bias conditions. A gain-bandwidth product as high as 0.3 was registered. The experimental results agreed well with the established theory for self-pumped parametric Josephson amplifiers. It should be possible to extend the low noise amplification by this device to mm wave frequencies. A relaxation oscillation occurred at a subharmonic of the Josephson frequency when the shunt loop inductance became large. The amplification in this mode followed closely the predictions of a simple model, where the signal modulated the switching of the sawtooth-like (relatively low frequency) relaxation current. Gains of about 15 dB were measured around 10 GHz, but the amplification was sensitive to bias conditions and noisy in this case where the relaxation frequency fell well below the signal frequency. Much improved properties were registered when the inductance was decreased so that the relaxation frequency approached the Josephson frequency and exceeded twice the signal frequency. The behavior then resembled that of a Josephson mode parametric amplifier, but the high content of harmonics of a relaxation oscillation meant that the amplifier became noisier due to converted noise from the many idler frequencies.

Journal of Applied Physics•Jul 1, 1982•26 citations
A parametric preamplifier of the up-converting type is described for use with SQUIDS. The amplifier works in a self-oscillatory mode. The theory of its operation, including equations for gain and noise properties, is presented. The design and performance of a built amplifier are described and possible improvements in the results discussed.
The application of superconducting (SQUID) galvanometers as low-noise preamplifiers with considerable bandwidth is explored. The important role of negative feedback in maximizing the bandwidth of these preamplifiers is carefully analyzed. Also discussed is the design and construction of superconducting impedance matching transformers suitable for making the unexcelled noise characteristics of these amplifiers available over a wide range of source impedances. A working preamplifier is described which has exhibited a maximum bandwidth of 10 kHz and noise temperatures in the liquid helium temperature range or below for all source impedances up to a few ohms. The operating characteristics of this preamplifier are compared to the best conventional room temperature amplifiers and are found to be superior for source impedances less than ∼10 Ω.
An improved read-out electronics without flux modulation for dc superconducting quantum interference devices (dc SQUIDs) is presented where the preamplifier is directly coupled to the SQUID. Compared to our previous designs, the 1/f voltage and current noise levels of the preamplifier were reduced by about a factor of 4 (rms) by using bipolar matched transistors instead of operational amplifiers at the input. Three types of flux-locked-loop electronics were developed and successfully tested: a low-power (120 mW) version for large multichannel arrays, a high-speed version with a 15 MHz bandwidth and a very fast (300 ns) reset mode, and a low-noise (0.44 nV/Hz) version with a fast and precise bias reversal circuit. The flux-locked-loop electronics are compatible with each other, so that only one type of low-power (180 mW) control unit is required to operate them. All essential specifications of practical SQUID systems (noise, dynamic behavior, and temperature stability) were determined by using liquid-helium and liquid-nitrogen cooled SQUIDs, respectively.
We describe a low-noise, two-stage dc Superconducting QUantum Interference Device (SQUID) amplifier that is designed for applications requiring high bandwidth and dynamic range. The output signal of a low-noise SQUID in the input stage coherently modulates a series array of identical SQUIDs in the output stage via a common modulation line. The input stage is designed so its output signal does not produce multiple modulation periods in the output stage. The output stage is designed to have sufficient gain so the output noise is dominated by the amplified noise of the input SQUID and exceeds the noise of a preamplifier in the room temperature readout electronics. The SQUID amplifier may therefore be operated without flux modulation or any impedance matching network, resulting in a large dynamic range and high bandwidth.
Experimental results are reported on a Josephson parametric upconverting amplifier which is self-pumped via the internal Josephson oscillations derived from a dc bias voltage. A niobium point-contact SQUID is simultaneously coupled to a 115-MHz tank circuit and a 9-GHz cavity. Josephson oscillations at 9 GHz produce parametric upconversion of power in the 115-MHz circuit to sidebands at 9±0.115 GHz with measured power gain of 25. The amplifier noise temperature, referred to the input at 115 MHz, was established to be <15 K by varying the temperature of an input termination from 4.2 to 300 K. This result establishes the behavior of self-pumped SQUID upconverters at microwave frequencies and demonstrates that the achievable noise performance is not greatly in excess of the thermal limit.
Kinetic inductance traveling-wave parametric amplifiers (KITs) are under development for the read out of large cryogenic detector arrays. We present new KIT designs based on 20nm NbTiN films patterned by use of standard optical photolithography. We report device gain, bandwidth, and noise properties, which approach the quantum limit. In addition, we demonstrate a KIT preamplifier with a microwave SQUID multiplexer. The improved input referred current noise, as compared to standard HEMT readout, opens up new possibilities for cryogenic receivers. We discuss these benefits.
The high-frequency amplification properties of transformer coupled, resistively shunted Josephson tunnel junctions have been investigated. The importance of the shunt loop inductance is stressed. It allows a high cutoff frequency, of significance for good high-frequency performance. The self-pumped parametric amplifier showed none of the excessive noise rise, which has hitherto plagued the development of externally pumped Josephson junction amplifiers. Around 10 GHz, we estimated a noise temperature less than 30 K for an amplifier pumped by a Josephson oscillation with a frequency well above twice the signal frequency. The corresponding gain of 5 dB may be increased in a better impedance matched circuit. The gain was very stable against variations in the bias conditions. A gain-bandwidth product as high as 0.3 was registered. The experimental results agreed well with the established theory for self-pumped parametric Josephson amplifiers. It should be possible to extend the low noise amplification by this device to mm wave frequencies. A relaxation oscillation occurred at a subharmonic of the Josephson frequency when the shunt loop inductance became large. The amplification in this mode followed closely the predictions of a simple model, where the signal modulated the switching of the sawtooth-like (relatively low frequency) relaxation current. Gains of about 15 dB were measured around 10 GHz, but the amplification was sensitive to bias conditions and noisy in this case where the relaxation frequency fell well below the signal frequency. Much improved properties were registered when the inductance was decreased so that the relaxation frequency approached the Josephson frequency and exceeded twice the signal frequency. The behavior then resembled that of a Josephson mode parametric amplifier, but the high content of harmonics of a relaxation oscillation meant that the amplifier became noisier due to converted noise from the many idler frequencies.