Journal of Applied Physics
Method for Calculating Simultaneous Resonance Conditions in a Three-Level Ruby Maser
Martin A. Garstens
Abstract
In operating a three-level maser one wishes to know the external magnetic field and crystal orientation necessary to match a given pair of frequencies. In the case of Cr+++ a fourth-degree secular equation determines four energy levels for each value of external field H and crystal orientation θ. Determination of the latter two variables, given two desired frequencies of operation, ordinarily involves either the solution of a tremendous number of fourth-degree equations and extrapolation towards the required solution, or determination of the matching conditions by experimental methods. In the following a method is described, allowing direct calculation of H and θ for a three-level ruby maser.