Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Superconducting noise bolometer for terahertz radiation

A. D. Semenov, Heiko Richter, Heinz‐Wilhelm Hübers, K. Ilin, M. Siegel

Published Oct 18, 2005• 6 citations
Publisher

Abstract

We present a superconducting noise bolometer that is a bolometric detector sensing radiation via radiation-induced changes of its own microwave noise. The detector represents a nanostrip made from a thin NbN superconducting film. It operates in the superconducting state and carries a supercurrent slightly less than the critical current. Radiation couples with the detector via an immersion lens and a planar antenna, which jointly define the useful spectral range from 1to5THz. At an ambient temperature of 4.2K, the optically measured noise-equivalent power amounts at ≈10−13WHz−1∕2 along with a time constant of approximately 150ps.

DOI
10.1063/1.2115086

Related papers

Current-noise superconducting bolometer for terahertz waves

Alexey Semenov, Heiko Richter, Heinz‐Wilhelm Hübers +3 more

An advantage of superconducting detectors is a much lower noise in comparison to their semiconductor counterparts. We have studied the magnitude and spectrum of electric noise in thin superconducting NbN nanostrips carrying a subcritical current. Analysis of the experimental data suggests that the noise appears due to fluctuations in the two-dimensional vortex gas below the Kosterlitz-Thouless phase transition. Implementing this approach to the noise mechanism, we proposed a novel detector. The novelty is the use of the noise, which generally hampers the performance of conventional detectors, as the physical quantity that itself senses radiation. Our detector patterned from a thin NbN superconducting film and integrated in a planar log-periodic antenna. The detector operates at 4.2 K in the current-carrying superconducting state. Optically measured noise-equivalent power amounted at 10-14 W Hz-1 and is likely to improve at lower temperatures.

•Jan 1, 2005•0 citations

Noise Bolometer for Terahertz Waves

Alexey Semenov, Heiko Richter, Heinz‐Wilhelm Hübers +3 more

An advantage of superconducting detectors is a much lower noise in comparison to their semiconductor counterparts. We have studied the magnitude and spectrum of electric noise in thin superconducting NbN nanostrips carrying a subcritical current. Analysis of the experimental data suggests that the noise appears due to fluctuations in the two-dimensional vortex gas below the Kosterlitz-Thouless phase transition. Implementing this approach to the noise mechanism, we proposed a novel detector. The novelty is the use of the noise, which generally hampers the performance of conventional detectors, as the physical quantity that itself senses radiation. Our detector patterned from a thin NbN superconducting film and integrated in a planar log-periodic antenna. The detector operates at 4.2 K in the current-carrying superconducting state. Optically measured noise-equivalent power amounted at 10^-13 W / Hz^1/2 and is likely to improve at lower temperatures.

•May 1, 2005•0 citations

Superconducting noise bolometer with microwave bias and readout for array applications

Artem A. Kuzmin, Alexei D. Semenov, S. V. Shitov +4 more

We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a 1.0 × 0.5 μm2 micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ≈3 × 10−12 W/Hz1/2, which is close to expectations for this particular device in the noise-response regime.

arXiv:1709.02997•Applied Physics Letters•Jul 24, 2017•8 citations

Terahertz Direct Detection Behavior of a Superconducting NbN bolometer by Noise Thermometry

Hao Gao, Wei Miao, Kangmin Zhou +1 more

In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2019•0 citations

Terahertz Direct Detectors Based on Superconducting Hot Electron Bolometers With Different Biasing Methods

Runfeng Su, Yi Di Zhang, Xuecou Tu +6 more

Terahertz (THz) direct detectors based on superconducting niobium nitride hot electron bolometers with thermal, microwave and THz biasing methods have been studied at a frequency of 0.65 THz and at an operating temperature of 4.2 K. A low noise amplifier at room temperature is used to read out the current change of the detectors modulated by the chopping frequency at 732 Hz. The noise spectral density, current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the microwave and THz biasing methods have about one order higher current responsivity than that of the thermal one. With the microwave biasing, an optical NEP at the order of pW/√Hz which shows no deterioration is obtained by choosing the microwave frequency and power appropriately.

IEEE Transactions on Applied Superconductivity•Apr 22, 2019•13 citations

Terahertz (THz) direct detectors based on superconducting HEBs with thermal, THz and microwave biasing methods (Conference Presentation)

Jian Chen

Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.

Next-Generation Spectroscopic Technologies•May 14, 2019•0 citations
We present a superconducting noise bolometer that is a bolometric detector sensing radiation via radiation-induced changes of its own microwave noise. The detector represents a nanostrip made from a thin NbN superconducting film. It operates in the superconducting state and carries a supercurrent slightly less than the critical current. Radiation couples with the detector via an immersion lens and a planar antenna, which jointly define the useful spectral range from 1to5THz. At an ambient temperature of 4.2K, the optically measured noise-equivalent power amounts at ≈10−13WHz−1∕2 along with a time constant of approximately 150ps.
An advantage of superconducting detectors is a much lower noise in comparison to their semiconductor counterparts. We have studied the magnitude and spectrum of electric noise in thin superconducting NbN nanostrips carrying a subcritical current. Analysis of the experimental data suggests that the noise appears due to fluctuations in the two-dimensional vortex gas below the Kosterlitz-Thouless phase transition. Implementing this approach to the noise mechanism, we proposed a novel detector. The novelty is the use of the noise, which generally hampers the performance of conventional detectors, as the physical quantity that itself senses radiation. Our detector patterned from a thin NbN superconducting film and integrated in a planar log-periodic antenna. The detector operates at 4.2 K in the current-carrying superconducting state. Optically measured noise-equivalent power amounted at 10-14 W Hz-1 and is likely to improve at lower temperatures.
An advantage of superconducting detectors is a much lower noise in comparison to their semiconductor counterparts. We have studied the magnitude and spectrum of electric noise in thin superconducting NbN nanostrips carrying a subcritical current. Analysis of the experimental data suggests that the noise appears due to fluctuations in the two-dimensional vortex gas below the Kosterlitz-Thouless phase transition. Implementing this approach to the noise mechanism, we proposed a novel detector. The novelty is the use of the noise, which generally hampers the performance of conventional detectors, as the physical quantity that itself senses radiation. Our detector patterned from a thin NbN superconducting film and integrated in a planar log-periodic antenna. The detector operates at 4.2 K in the current-carrying superconducting state. Optically measured noise-equivalent power amounted at 10^-13 W / Hz^1/2 and is likely to improve at lower temperatures.
We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a 1.0 × 0.5 μm2 micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ≈3 × 10−12 W/Hz1/2, which is close to expectations for this particular device in the noise-response regime.
In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.
Terahertz (THz) direct detectors based on superconducting niobium nitride hot electron bolometers with thermal, microwave and THz biasing methods have been studied at a frequency of 0.65 THz and at an operating temperature of 4.2 K. A low noise amplifier at room temperature is used to read out the current change of the detectors modulated by the chopping frequency at 732 Hz. The noise spectral density, current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the microwave and THz biasing methods have about one order higher current responsivity than that of the thermal one. With the microwave biasing, an optical NEP at the order of pW/√Hz which shows no deterioration is obtained by choosing the microwave frequency and power appropriately.
Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.