A quantum-limited light-scattering system is considered. The spatial configuration that maximizes a given figure of merit is investigated, assuming that the emitted light has Poisson photon statistics. A specific system for measuring the velocity of a small particle is considered as an example. An optimum spatial code is found for the case of dominating intrinsic signal noise. The robustness of this solution is discussed in relation to the case of dominating background noise.
A quantum-limited light-scattering system is considered. The spatial configuration that maximizes a given figure of merit is investigated, assuming that the emitted light has Poisson photon statistics. A specific system for measuring the velocity of a small particle is considered as an example. An optimum spatial code is found for the case of dominating intrinsic signal noise. The robustness of this solution is discussed in relation to the case of dominating background noise.
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
A limitation of free-space optical communications is the ease with which the information can be intercepted. Overcoming this limitation is possible by hiding the information within the background optical noise that is present in all real-world situations. We demonstrate the limitations of our experimental system for transferring images over free-space using a photon-pair source emitting two correlated beams. The system uses spontaneous parametric down-conversion to create photon-pairs, where one photon contains the spatial information and the other the heralding information.
Because of quantum noise fluctuations, the rate of error achievable in decision problems involving several possible configurations of a scattering system is subject to a fundamental limit known as the Helstrom bound. Here, we present a general framework to calculate and minimize this bound using coherent probe fields with tailored spatial distributions. As an example, we experimentally study a target located in between two disordered scattering media. We first show that the optimal field distribution can be directly identified using a general approach based on scattering matrix measurements. We then demonstrate that this optimal light field successfully probes the presence of the target with a number of photons that is reduced by more than 2 orders of magnitude as compared to unoptimized fields.
In metrology, Fisher information is an important metric that quantifies the precision that can be achieved in a measurement. For optical measurements using coherent light it has been shown that Fisher information can be expressed simply using the scattering matrix of the system. Fisher information can be maximized over the input modes to achieve maximum information states, which produce optimally precise estimates for a parameter when the system is limited by photon noise. Here, we extend this approach to multiparameter estimation, in which case Fisher information takes the form of a matrix. We consider several scalar functions of the Fisher matrix to optimize the precision in multiple parameters at the same time. We also consider strategies for dealing with nuisance parameters, which can degrade the achievable precision of other parameters but are not of interest to measure. We corroborate our findings numerically using a scattering system of 2D coupled dipoles.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
We present a quantum theory of light scattering for the analysis of the quantum statistical and fluctuation properties of light scattered or emitted by micrometric and nanometric three-dimensional structures of arbitrary shape. We obtain general three-dimensional quantum-optical input-output relations providing the output photon operators in terms of the input photon operators and of the noise currents of the scattering system. These relations hold also for photon operators associated with evanescent fields, for anisotropic scattering systems and/or for media with a nonlocal susceptibility. We find that the commutation relations of the output photon operators, carrying all the information on the scattering and/or the emission process, result to be fixed by energy conservation and reciprocity. We prove that this quantization scheme is consistent with QED commutation rules by using a novel relationship between vacuum and thermal fluctuations. This theoretical framework has been applied to analyze the spectral density of light close to a point scatterer under different nonequilibrium conditions.