Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Continuous-wave quantum nondemolition measurements with vacuum and nonclassical meter input

Robert Bruckmeier, K. Schneider, Hauke Hansen, Manfred Schalke, Stephan Schiller, J. Mlynek

Published Jan 29, 1997• 7 citations
Publisher
DOI
10.1007/s003400050165

Related papers

Improved Quantum Nondemolition Measurement Using a Squeezed Meter Input

Robert Bruckmeier, K. Schneider, Hauke Hansen +2 more

European Quantum Electronics Conference (EQEC)•Jan 1, 1996•0 citations

Quantum nondemolition measurement of atomic inversion and generation of nonclassical atomic states

Shi‐Biao Zheng

Optics Communications•Dec 1, 1998•0 citations

Quantum Nondemolition Measurements Improved by a Squeezed Meter Input

Robert Bruckmeier, Klaus Schneider, Stephan Schiller +1 more

Continuous quantum nondemolition (QND) measurements of the amplitude quadrature of a 1064 nm wave are performed with a monolithic dual-port degenerate optical parametric amplifier (OPA). The quality of the measurement is limited in part by the quantum fluctuations carried by the vacuum meter input wave. Improved QND measurements are realized by injecting 3.4 dB amplitude-squeezed light into the meter input port of the OPA. This achieves increased squeezing and correlation of the output signal and meter waves, and both improved operation as a quantum optical tap and as a quantum state preparator. The all-solid-state system was operated for 5 h with high stability.

Physical Review Letters•Feb 17, 1997•35 citations

Quantum nondemolition measurement with a nonclassical meter input and an electro-optic enhancement

Ulrik L. Andersen, B. C. Buchler, Hans‐A. Bachor +1 more

Optical quantum nondemolition measurements are performed using a beamsplitter with a nonclassical meter input and a electro-optic feedforward loop. The nonclassical meter input is provided by a stable 4.5 dB amplitude squeezed source generated by an optical parametric amplifier. We show that the implementation of a feedforward loop gives a substantial improvement in the signal transfer efficiency. With a 92% reflective beamsplitter we measure a transfer coefficient of Ts+m = 1.81. The quantum state preparation ability of our system is evaluated using two-dimensional correlation plots. This technique allows the direct visualization of the quantum correlations between the outputs of the QND system.

Journal of Optics B Quantum and Semiclassical Optics•Apr 5, 2002•8 citations

Quantum Nondemolition Measurements in Quantum Optics

Gerard J Milburn, Daniel F. Walls

Springer eBooks•Jan 1, 1984•1 citation

Realization and Characterization of Quantum Nondemolition Measurements in Optics

J.-Ph. Poizat, Jean-François Roch, Philippe Grangier

Springer eBooks•Jan 1, 1995•0 citations
Continuous quantum nondemolition (QND) measurements of the amplitude quadrature of a 1064 nm wave are performed with a monolithic dual-port degenerate optical parametric amplifier (OPA). The quality of the measurement is limited in part by the quantum fluctuations carried by the vacuum meter input wave. Improved QND measurements are realized by injecting 3.4 dB amplitude-squeezed light into the meter input port of the OPA. This achieves increased squeezing and correlation of the output signal and meter waves, and both improved operation as a quantum optical tap and as a quantum state preparator. The all-solid-state system was operated for 5 h with high stability.
Optical quantum nondemolition measurements are performed using a beamsplitter with a nonclassical meter input and a electro-optic feedforward loop. The nonclassical meter input is provided by a stable 4.5 dB amplitude squeezed source generated by an optical parametric amplifier. We show that the implementation of a feedforward loop gives a substantial improvement in the signal transfer efficiency. With a 92% reflective beamsplitter we measure a transfer coefficient of Ts+m = 1.81. The quantum state preparation ability of our system is evaluated using two-dimensional correlation plots. This technique allows the direct visualization of the quantum correlations between the outputs of the QND system.