Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Quantum beats observed in photoionization

Gerd Leuchs, Stephen J. Smith, E.E. Khawaja, HERBERT WALTHER

Published Dec 1, 1979• 64 citations
Publisher
DOI
10.1016/0030-4018(79)90204-9

Related papers

The origin of quantum beats in photoionization

P. L. Knight

Optics Communications•Feb 1, 1980•21 citations

Observation of Quantum Beats of Two-Photon-Excited States of Xe upon Photoionization

E. A. Viktorov, A. A. Pastor, Pavel Yu. Serdobintsev +1 more

Abstract Ionization of coherently two-photon-excited superposition of 4f states of Xe in a supersonic atomic beam is studied by means of femtosecond pump–probe spectroscopy. Oscillatory structure in the photoionization signal is related to coherent beats of a superposition of excited states. High efficiency of the proposed scheme of registration of quantum beats was achieved due to nearly 100% efficiency of collecting photoelectrons, in contrast to detection of fluorescence used traditionally.

Optics and Spectroscopy•Dec 1, 2021•4 citations

Modulation of quantum beats signal upon photoionization of Xe isotopes in the magnetic field

E. A. Viktorov, SERDOBINTSEV P.YU., Nikolai N. Bezuglov +1 more

Photoionization processes involving polarized Xe atoms in the presence of an external magnetic field were analyzed in our previous studies. It was shown that the modulation of quantum beats in the observed electronic photo signals could not be explained by the Paschen-Back effect accounting for fine-structure levels only. In the current work, ionized Xe+ isotopes are used as the output channel of photoionization. By comparing the temporal partial signals in the mass spectra of the Xe+ isotopes, it was possible to explain the modulation of quantum beats in ion fluxes as a consequence of the presence of the hyperfine structure in the Zeeman components of the 129Xe and 131Xe isotopes. Keywords: quantum beats, hyperfine structure, Zeeman effect, two-photon excitation, femtosecond ionization, "pump-probe"-experiment.

Оптика и спектроскопия•Jan 1, 2022•0 citations

Complete Experiments in Atomic Photoionization

Hans Kleinpoppen, Bernd Lohmann, Alexei N. Grum-Grzhimailo

Springer series on atomic, optical, and plasma physics•Jan 1, 2013•2 citations

Quantum beats in photoionization from a coherent superposition of fine-structure levels

A. T. Georges, P. Lambropoulos

We present a theory of quantum beats in photoionization from a coherent superposition of ${D}_{\frac{3}{2},5.2}$ levels in alkali-metal atoms. The semiclassical density-matrix formalism is used to describe both the excitation of the ${D}_{\frac{3}{2},\frac{5}{2}}$ levels by a two-photon resonant pulse and the subsequent photoionization by a delayed probe pulse. Quantum beats occur in the ionization signal as a function of the delay of the probe pulse. The depth of modulation is determined for different light polarizations.

Physical Review A•Sep 1, 1978•35 citations

Photoionization of atomic systems

Philip George Burke

Elsevier eBooks•Jan 1, 1976•6 citations
Photoionization processes involving polarized Xe atoms in the presence of an external magnetic field were analyzed in our previous studies. It was shown that the modulation of quantum beats in the observed electronic photo signals could not be explained by the Paschen-Back effect accounting for fine-structure levels only. In the current work, ionized Xe+ isotopes are used as the output channel of photoionization. By comparing the temporal partial signals in the mass spectra of the Xe+ isotopes, it was possible to explain the modulation of quantum beats in ion fluxes as a consequence of the presence of the hyperfine structure in the Zeeman components of the 129Xe and 131Xe isotopes. Keywords: quantum beats, hyperfine structure, Zeeman effect, two-photon excitation, femtosecond ionization, "pump-probe"-experiment.
We present a theory of quantum beats in photoionization from a coherent superposition of D32,5.2{D}_{\frac{3}{2},5.2}D23​,5.2​ levels in alkali-metal atoms. The semiclassical density-matrix formalism is used to describe both the excitation of the D32,52{D}_{\frac{3}{2},\frac{5}{2}}D23​,25​​ levels by a two-photon resonant pulse and the subsequent photoionization by a delayed probe pulse. Quantum beats occur in the ionization signal as a function of the delay of the probe pulse. The depth of modulation is determined for different light polarizations.