Review of Scientific Instruments

A multiple pin, flip-chip system for microwave and gigabit per second cryogenic device testing at variable temperatures

M. S. Wire, D.J. Durand, Arnold H. Silver, M. K. Wagner, C.A. Hamilton

Published Feb 1, 2001• 6 citations
Publisher

Abstract

We have developed a cryogenic probe and cryostat system to test both active and passive superconducting devices and circuits up to microwave frequencies at variable temperatures. Our system consists of two basic parts: the cryostat and the matching probe. The cryostat is a unique, very efficient, variable temperature, flow-type cryostat, where we control temperature without electrical heaters. It is magnetically shielded and allows rapid testing between 4.2 K and room temperature. Probes developed for this cryostat have a larger number of shorter cables than standard dip-type probes. They are designed to test chips or chip assemblies without additional packaging. Chips or chip assemblies can be quickly mounted and dismounted from a fixed spring-contact assembly. Each probe has 56 wide-bandwidth signal cables. We have repeatedly used these probes for testing both active and passive superconducting integrated circuits up to 20 GHz. The probe and cryostat combination provides a testing capability that is simultaneously high frequency, dc magnetic shielded, has variable cryogenic temperature, and quick turnaround.

DOI
10.1063/1.1337072

Related papers

High performance packaging system for superconducting electronics

Dmitri V. Gaidarenko, R. P. Robertazzi

We demonstrate a packaging system/test probe suitable for testing complex, large scale superconducting integrated circuits with thousands of Josephson junctions. The cryopackage is designed to work with a 1 cm superconducting die, with liquid He immersion cooling using a standard storage dewar. The package has 80 high-speed input-output lines (DC to 20 GHz) which connect the chip to room temperature electronics. The tip of the cryopackage, containing the chip, is shielded from the ambient magnetic field with two mumetal cylinders and contains a built-in coil, which provides in-situ degaussing of the inner shield. To clear flux trapped in the chip being tested, the probe contains a novel gas manifold and a system of heaters. During the defluxing operation, a heater evaporates liquid helium inside the chip enclosure, the expanding vapor purging the liquid from the sample cell and warming the chip above its transition temperature. Once the chip is defluxed, the liquid helium is allowed back into the cell, at a rate slow enough to avoid trapping flux in the chip while it is cooled. The process can be automated and does not require any movement of the probe once inserted in the dewar.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•10 citations

Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures

Paul Julius Ritter, Marc-André Tucholke, Marius Neumann +8 more

Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance-voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system's measurement capability for quantum computing and other applications.

Review of Scientific Instruments•Apr 1, 2025•9 citations

Cryogenic Test-Bed Applied to 9 K NbN RSFQ Devices Operation

Mario Aurino, Emanuele Baggetta, Sophie Bouat +5 more

NbN RSFQ circuits operating at 9 K reduce the cooling constraints especially for portable, remote, telecoms or medical imaging applications. We have developed a test-bed to study the operating temperature of the various mixed RF and digital circuit blocks of NbN ‘HyperSCAN’ project test vehicle 1${\rm cm}^{2}$chips. The use of a widespread helium cryostat (‘Orange-ILL’) allows us to stabilize the chip temperature in the range 2.9 K–20 K with thermal oscillations lower than 0.1 K. The chip is mounted on a PCB and shielded from the external field: the PCB provides a multi-connection packaging used in order to study temperature and frequency operation of 30 GHz NbTiN CPW filters, RSFQ gates, analog SQUID and NbN/TaN/NbN SNS junctions arrays. The comparison between electrical simulations and tests is made on flexible,$\sim$56 cm long, micro-strip line ribbon cable carrying 32 signals each including bias lines, in the range of DC-3 GHz, combined with 4 semi-rigid$\sim$40 GHz coaxial cables. By removing spurious resonances, it is expected to take full benefit of the large bandwidth, low insertion loss and low thermal conductivity of the set-up. We emphasis on the flexibility, large yield, reliability and reduced cost of such packaging coupled to He cooling exchanger for applying to testers and to future 9 K NbN multi-ADC green and remote systems when only low electrical power sources are available.

IEEE Transactions on Applied Superconductivity•Nov 23, 2010•2 citations

Room Temperature Interface for RSFQ Digital Signal Processor

Henrik Engseth, Rizwan Rafique, Irina Kataeva +2 more

This paper describes a cryogenic multi-chip module (MCM) probe for testing of a superconducting hybrid digital signal processor (DSP) capable of 24 giga multiply accumulate operations per second. The probe has 39 data channels with 4 GHz bandwidth, a 30 GHz high speed clock input line, and 48 biasing lines. The MCM interface board features 164 spring finger contacts for a 30 times 30 mm2MCM. The probe has low heatload (0.23 W) and provides good magnetic shielding with residual field equal to 250Phi0over a 5 times 5 mm2area. The measured time skew between 20 of the 1200 mm data coaxial lines is about 70 ps. The probe allows synchronous data word transmission at 2 Gbps.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•3 citations

A noncontact cryogenic microwave measurement system for superconducting device characterization

Alp Tugrul Findikoglu, T. Nakamura, Hitoki Tokuda +1 more

A noncontact cryogenic microwave measurement system has been developed for the characterization of passive and active superconducting devices by means of an unloaded quality factor measurement technique. The measurement system was designed specifically for the characterization of planar thin film resonant structures as a function of temperature (4–300 K), frequency (100 MHz–26.5 GHz), and dc voltage bias (≤100 V). It has been used for basic device studies of novel active superconducting lumped components made of metal-oxide superconductor/insulator heterostructures.

Review of Scientific Instruments•Sep 1, 1994•0 citations

Setup and Design of a Cryogenic Testing Station with Focus on Characterization of Superconducting Devices

Clifford E. Plesha

The goal of my thesis was to construct a general purpose cryostat, capable of measuring multiple devices at 100mK. This included modifying an existing SHASTA model 106 Adiabatic Demagnetization Refrigerator (ADR) by adding a new physical support structure to allow for more weight to be added to the cryostat’s testing stages, as well as custom pieces of electronics, such as a room temperature programmable current source. This allowed for computer programs to be written so we could automate the data acquisition process. \nWe successfully measured multiple superconducting quantum interference devices (SQUIDs), with the goal of proving that our custom electronics were able to control and record the output of the SQUID. This included measuring the biasing conditions of the SQUID with \nthe automated current sources, as well as measuring the noise temperature of a SQUID down to 300mK. Furthermore, we measured the thermal conductivity of our new sup- port structure for the cryostat and were able to prove that the material used was new \nand novel approach for high strength, low thermal conductivity in cryogenic research. We also investigated a new technique in permanently modifying the operational frequency of a SQUID, and were able to show that this new method of laser ablating the input coil could successfully shift the frequency. While the focus of cryogenic testing was on SQUIDs the cryostat itself was designed in such a way such that many types of low temperature devices could be tested within the system.

•May 23, 2019•1 citation
We have developed a cryogenic probe and cryostat system to test both active and passive superconducting devices and circuits up to microwave frequencies at variable temperatures. Our system consists of two basic parts: the cryostat and the matching probe. The cryostat is a unique, very efficient, variable temperature, flow-type cryostat, where we control temperature without electrical heaters. It is magnetically shielded and allows rapid testing between 4.2 K and room temperature. Probes developed for this cryostat have a larger number of shorter cables than standard dip-type probes. They are designed to test chips or chip assemblies without additional packaging. Chips or chip assemblies can be quickly mounted and dismounted from a fixed spring-contact assembly. Each probe has 56 wide-bandwidth signal cables. We have repeatedly used these probes for testing both active and passive superconducting integrated circuits up to 20 GHz. The probe and cryostat combination provides a testing capability that is simultaneously high frequency, dc magnetic shielded, has variable cryogenic temperature, and quick turnaround.
We demonstrate a packaging system/test probe suitable for testing complex, large scale superconducting integrated circuits with thousands of Josephson junctions. The cryopackage is designed to work with a 1 cm superconducting die, with liquid He immersion cooling using a standard storage dewar. The package has 80 high-speed input-output lines (DC to 20 GHz) which connect the chip to room temperature electronics. The tip of the cryopackage, containing the chip, is shielded from the ambient magnetic field with two mumetal cylinders and contains a built-in coil, which provides in-situ degaussing of the inner shield. To clear flux trapped in the chip being tested, the probe contains a novel gas manifold and a system of heaters. During the defluxing operation, a heater evaporates liquid helium inside the chip enclosure, the expanding vapor purging the liquid from the sample cell and warming the chip above its transition temperature. Once the chip is defluxed, the liquid helium is allowed back into the cell, at a rate slow enough to avoid trapping flux in the chip while it is cooled. The process can be automated and does not require any movement of the probe once inserted in the dewar.
Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance-voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system's measurement capability for quantum computing and other applications.
NbN RSFQ circuits operating at 9 K reduce the cooling constraints especially for portable, remote, telecoms or medical imaging applications. We have developed a test-bed to study the operating temperature of the various mixed RF and digital circuit blocks of NbN ‘HyperSCAN’ project test vehicle 1cm2{\rm cm}^{2}cm2chips. The use of a widespread helium cryostat (‘Orange-ILL’) allows us to stabilize the chip temperature in the range 2.9 K–20 K with thermal oscillations lower than 0.1 K. The chip is mounted on a PCB and shielded from the external field: the PCB provides a multi-connection packaging used in order to study temperature and frequency operation of 30 GHz NbTiN CPW filters, RSFQ gates, analog SQUID and NbN/TaN/NbN SNS junctions arrays. The comparison between electrical simulations and tests is made on flexible,$\sim56cmlong,micro−striplineribboncablecarrying32signalseachincludingbiaslines,intherangeofDC−3GHz,combinedwith4semi−rigid56 cm long, micro-strip line ribbon cable carrying 32 signals each including bias lines, in the range of DC-3 GHz, combined with 4 semi-rigid56cmlong,micro−striplineribboncablecarrying32signalseachincludingbiaslines,intherangeofDC−3GHz,combinedwith4semi−rigid\sim$40 GHz coaxial cables. By removing spurious resonances, it is expected to take full benefit of the large bandwidth, low insertion loss and low thermal conductivity of the set-up. We emphasis on the flexibility, large yield, reliability and reduced cost of such packaging coupled to He cooling exchanger for applying to testers and to future 9 K NbN multi-ADC green and remote systems when only low electrical power sources are available.
This paper describes a cryogenic multi-chip module (MCM) probe for testing of a superconducting hybrid digital signal processor (DSP) capable of 24 giga multiply accumulate operations per second. The probe has 39 data channels with 4 GHz bandwidth, a 30 GHz high speed clock input line, and 48 biasing lines. The MCM interface board features 164 spring finger contacts for a 30 times 30 mm2MCM. The probe has low heatload (0.23 W) and provides good magnetic shielding with residual field equal to 250Phi0over a 5 times 5 mm2area. The measured time skew between 20 of the 1200 mm data coaxial lines is about 70 ps. The probe allows synchronous data word transmission at 2 Gbps.
A noncontact cryogenic microwave measurement system has been developed for the characterization of passive and active superconducting devices by means of an unloaded quality factor measurement technique. The measurement system was designed specifically for the characterization of planar thin film resonant structures as a function of temperature (4–300 K), frequency (100 MHz–26.5 GHz), and dc voltage bias (≤100 V). It has been used for basic device studies of novel active superconducting lumped components made of metal-oxide superconductor/insulator heterostructures.
The goal of my thesis was to construct a general purpose cryostat, capable of measuring multiple devices at 100mK. This included modifying an existing SHASTA model 106 Adiabatic Demagnetization Refrigerator (ADR) by adding a new physical support structure to allow for more weight to be added to the cryostat’s testing stages, as well as custom pieces of electronics, such as a room temperature programmable current source. This allowed for computer programs to be written so we could automate the data acquisition process. \nWe successfully measured multiple superconducting quantum interference devices (SQUIDs), with the goal of proving that our custom electronics were able to control and record the output of the SQUID. This included measuring the biasing conditions of the SQUID with \nthe automated current sources, as well as measuring the noise temperature of a SQUID down to 300mK. Furthermore, we measured the thermal conductivity of our new sup- port structure for the cryostat and were able to prove that the material used was new \nand novel approach for high strength, low thermal conductivity in cryogenic research. We also investigated a new technique in permanently modifying the operational frequency of a SQUID, and were able to show that this new method of laser ablating the input coil could successfully shift the frequency. While the focus of cryogenic testing was on SQUIDs the cryostat itself was designed in such a way such that many types of low temperature devices could be tested within the system.