Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

High-Accuracy Optical Homodyne Detection with Low-Efficiency Detectors: "Preamplification" from Antisqueezing

Ulf Leonhardt, Henryk Paul

Published Jun 27, 1994• 77 citations
Publisher

Abstract

A novel experimental scheme is proposed that allows us to avoid the deterioration of homodyne detection measurements due to nonideal detectors. The basic idea is to "preamplify" the signal by means of antisqueezing. Experimentally, we would employ a squeezer, e.g., a degenerate optical parametric amplifier, that squeezes just the nonobserved quadrature component of the electric field while antisqueezing the conjugate component which is measured. It is shown that for sufficiently strong antisqueezing one achieves the same measurement accuracy as with perfectly efficient detectors. In particular, in this way the actual Wigner function can be reconstructed in cptical homodyne tomography.

DOI
10.1103/physrevlett.72.4086

Related papers

Signal-to-noise ratio of preamplified homodyne detection in quantum tomography

Marcelo A. Marchiolli, Salomon Sylvain Mizrahi, V. V. Dodonov

The operational theory of homodyne detection by nonideal detectors, used in quantum tomography, was recently modified in order to incorporate the preamplification (before homodyne detection) of the input signal, thus enabling one to beat the handicap of the lower than 0.5 detector efficiency. In the present work we set expressions for the Mandel $Q$ parameter and the signal-to-noise ratio in terms of the operational (measured) moments of the preamplified homodyne detection formalism. These quantities furnish important information on the statistical properties of the input signal field and the photocounts at the output. We illustrate the theory by considering several kinds of fields (for the input signal) and determine the effects of the preamplification on the output signal-to-noise ratios. Here we essentially verify that (i) the preamplification shifts the statistics towards the super-Poissonian limit, without jeopardizing the capacity of reconstructing a sub-Poissionan input signal, and (ii) the preamplification is more effective, i.e., the rate of increase of the signal-to-noise ratio of the output photocount is larger for low-efficiency detectors than for ideal ones.

Physical Review A•May 1, 1998•9 citations

Squeezing and antisqueezing in homodyne measurements

M. S. Kim, Barry C. Sanders

Squeezing the signal field or the local oscillator can improve the accuracy of homodyne detection. We show that an equivalence exists between antisqueezing the signal field and squeezing the local oscillator state. The importance of this result is illustrated in two contexts: a homodyne measurement of squeezing and the reconstruction of the wave function. \textcopyright{} 1996 The American Physical Society.

Physical Review A•May 1, 1996•23 citations

OPA tomography of non-Gaussian states of light

Éva Rácz, László Ruppert, Radim Filip

Abstract Current advances in nonlinear optics have made it possible to perform a homodyne-like tomography of an unknown state without highly efficient detectors or a strong local oscillator. Thereby, a new experimental direction has been opened into multimode and large-bandwidth quantum optics. An optical parametric amplifier (OPA) allows us to reconstruct the quadrature distribution of an unknown state directly from the measured intensity distribution with high precision. We propose adding a controllable displacement to the standard scheme, thus, obtaining a method applicable even to asymmetric and non-Gaussian states while significantly increasing estimation accuracy and lowering the OPA amplification requirement. To demonstrate the power of our method, we accurately detect the sub-Planck phase-space structure by obtaining distillable squeezing from the OPA estimates of various non-Gaussian states. With the improvements, OPA tomography became a generally applicable loss-tolerant and efficient alternative to homodyne detection.

arXiv:2310.18821•Quantum Science and Technology•Sep 13, 2024•6 citations

Quantum interferences reconstruction with low homodyne detection efficiency

Martina Esposito, Francesco Randi, Kelvin Titimbo +7 more

Optical homodyne tomography consists in reconstructing the quantum state of an optical field from repeated measurements of its amplitude at different field phases (homodyne data). The experimental noise, which unavoidably affects the homodyne data, leads to a detection efficiency $\eta<1$ . The problem of reconstructing quantum states from noisy homodyne data sets prompted an intense scientific debate about the presence or absence of a lower homodyne efficiency bound ( $\eta> 0.5$ ) below which quantum features, like quantum interferences, cannot be retrieved. Here, by numerical experiments, we demonstrate that quantum interferences can be effectively reconstructed also for low homodyne detection efficiency. In particular, we address the challenging case of a Schrödinger cat state and test the minimax and adaptive Wigner function reconstruction technique by processing homodyne data distributed according to the chosen state but with an efficiency $\eta< 0.5$ . By numerically reproducing the Schrödinger’s cat interference pattern, we give evidence that quantum state reconstruction is actually possible in these conditions, and provide a guideline for handling optical tomography based on homodyne data collected by low efficiency detectors.

arXiv:1508.07799•EPJ Quantum Technology•May 4, 2016•6 citations

Realistic Measurement of Phase

Henryk Paul, Ulf Leonhardt

The experimental schemes for measuring quantum-mechanical phase properties of light suggested and partly also realized thus far, namely (i) amplification, with the help of a quantum amplifier, of the microscopic field before phase measurement, (ii) heterodyning the field with a strong local oscillator, and (iii) performing two separate homodyne measurements on the field after beam splitting, are compared from a theoretical point of view.They share the common feature that undesired noise enters the experimental setup, which makes the measurement fuzzy.It will be pointed out that all three schemes amount to measuring the Q function of the original field, and hence are fully equivalent.Since the Q function can be interpreted as a smoothed Wigner function, one may associate with the introduced noise a smoothing process in which intrinsically quantum-mechanical features displayed by finer details of the Wigner function -especially by the occurrence of negative values -are lost.As a consequence, the measured phase distribution will be broader than the "true" one based on the concept of a quantum-mechanical phase operator.In realistic experiments, the nonunit detection efficiency further deteriorates the measuring results.It will be shown that also this echect can be properly described by an (additional) smoothing process leading to a certain s-parametrized quasiprobability distribution, with a parameter s that is connected with the detection efficiency in a simple way, as the distribution that is actually measurable.

Acta Physica Polonica A•Jul 1, 1994•3 citations

Enhancement of detection efficiencies in homodyne measurements Comparison between squeezing signal fields and squeezing local oscillator fields

M. S. Kim

It is known that squeezing the signal field can enhance the detection efficiency in Wigner function measurements using optical tomography. There exists an equivalence between squeezing the signal field and squeezing the local oscillator state when the detection efficiency is unity. We compare the cases of squeezing the local oscillator field and squeezing the signal field in the light of improving the detection efficiency in homodyne measurements.

Journal of Modern Optics•Aug 1, 1997•2 citations
A novel experimental scheme is proposed that allows us to avoid the deterioration of homodyne detection measurements due to nonideal detectors. The basic idea is to "preamplify" the signal by means of antisqueezing. Experimentally, we would employ a squeezer, e.g., a degenerate optical parametric amplifier, that squeezes just the nonobserved quadrature component of the electric field while antisqueezing the conjugate component which is measured. It is shown that for sufficiently strong antisqueezing one achieves the same measurement accuracy as with perfectly efficient detectors. In particular, in this way the actual Wigner function can be reconstructed in cptical homodyne tomography.
The operational theory of homodyne detection by nonideal detectors, used in quantum tomography, was recently modified in order to incorporate the preamplification (before homodyne detection) of the input signal, thus enabling one to beat the handicap of the lower than 0.5 detector efficiency. In the present work we set expressions for the Mandel QQQ parameter and the signal-to-noise ratio in terms of the operational (measured) moments of the preamplified homodyne detection formalism. These quantities furnish important information on the statistical properties of the input signal field and the photocounts at the output. We illustrate the theory by considering several kinds of fields (for the input signal) and determine the effects of the preamplification on the output signal-to-noise ratios. Here we essentially verify that (i) the preamplification shifts the statistics towards the super-Poissonian limit, without jeopardizing the capacity of reconstructing a sub-Poissionan input signal, and (ii) the preamplification is more effective, i.e., the rate of increase of the signal-to-noise ratio of the output photocount is larger for low-efficiency detectors than for ideal ones.
Abstract Current advances in nonlinear optics have made it possible to perform a homodyne-like tomography of an unknown state without highly efficient detectors or a strong local oscillator. Thereby, a new experimental direction has been opened into multimode and large-bandwidth quantum optics. An optical parametric amplifier (OPA) allows us to reconstruct the quadrature distribution of an unknown state directly from the measured intensity distribution with high precision. We propose adding a controllable displacement to the standard scheme, thus, obtaining a method applicable even to asymmetric and non-Gaussian states while significantly increasing estimation accuracy and lowering the OPA amplification requirement. To demonstrate the power of our method, we accurately detect the sub-Planck phase-space structure by obtaining distillable squeezing from the OPA estimates of various non-Gaussian states. With the improvements, OPA tomography became a generally applicable loss-tolerant and efficient alternative to homodyne detection.
Optical homodyne tomography consists in reconstructing the quantum state of an optical field from repeated measurements of its amplitude at different field phases (homodyne data). The experimental noise, which unavoidably affects the homodyne data, leads to a detection efficiency η<1\eta<1η<1 . The problem of reconstructing quantum states from noisy homodyne data sets prompted an intense scientific debate about the presence or absence of a lower homodyne efficiency bound ( η>0.5\eta> 0.5η>0.5 ) below which quantum features, like quantum interferences, cannot be retrieved. Here, by numerical experiments, we demonstrate that quantum interferences can be effectively reconstructed also for low homodyne detection efficiency. In particular, we address the challenging case of a Schrödinger cat state and test the minimax and adaptive Wigner function reconstruction technique by processing homodyne data distributed according to the chosen state but with an efficiency η<0.5\eta< 0.5η<0.5 . By numerically reproducing the Schrödinger’s cat interference pattern, we give evidence that quantum state reconstruction is actually possible in these conditions, and provide a guideline for handling optical tomography based on homodyne data collected by low efficiency detectors.
The experimental schemes for measuring quantum-mechanical phase properties of light suggested and partly also realized thus far, namely (i) amplification, with the help of a quantum amplifier, of the microscopic field before phase measurement, (ii) heterodyning the field with a strong local oscillator, and (iii) performing two separate homodyne measurements on the field after beam splitting, are compared from a theoretical point of view.They share the common feature that undesired noise enters the experimental setup, which makes the measurement fuzzy.It will be pointed out that all three schemes amount to measuring the Q function of the original field, and hence are fully equivalent.Since the Q function can be interpreted as a smoothed Wigner function, one may associate with the introduced noise a smoothing process in which intrinsically quantum-mechanical features displayed by finer details of the Wigner function -especially by the occurrence of negative values -are lost.As a consequence, the measured phase distribution will be broader than the "true" one based on the concept of a quantum-mechanical phase operator.In realistic experiments, the nonunit detection efficiency further deteriorates the measuring results.It will be shown that also this echect can be properly described by an (additional) smoothing process leading to a certain s-parametrized quasiprobability distribution, with a parameter s that is connected with the detection efficiency in a simple way, as the distribution that is actually measurable.